[ B ] Printout of firmware switch data ■ Function The equipment prints out the setting items and contents specified by the firmware switches. ■ Operating Procedure (1) Press the Q key twice in the initial maintenance mode. The "PRINTING" will appear on the LCD. (2) The equipment prints out the configuration list as shown in the figure below. (3) Upon completion of printing, the equipment returns to the initial maintenance mode. CONFIGURATION LIST WSW01 = 00000000 1-2. DIAL FORMAT 3-4. BREAK TIME 5-6. INTERDIGIT PAUSE 7. DP/PB CHANGE IN USER SW 8. DP/PB FIXING SELECTION WSW02 = 11111010 1-2. ON TIME 3-4. OFF TIME 5-8. LINE BEEP ATTENUATOR WSW03 = 10000000 1. PARA. CNG DETECTION1 2-4. NOT USED 5. PARA. CNG DETECTION2 6-8. NOT USED WSW04 = 00010101 1-8. NOT WSW32 = 01010000 1-8. NOT USED WSW33 = 10000010 1-8. NOT USED WSW34 = 01010000 1-5. NOT USED 6-7. DTMF DIGIT FOR CNG DETECTION 8. NOT USED : NORMAL : 60 MS : 800 MS : YES : PB : 100 MS : 140 MS : 10 DB : B A : 3 MODEL: 5X1-S13 TIME : 06/04/1996 16:40 REV. : UG2372001 VER.A SUM : 5279 Configuration List V - 45