Connections inside the control box, P6 YPM BLUE
View all Brother International RH-981A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
3. INSTALLATION 3-12-1. Connections inside the control box 2997Q 1. Open the rear cover (1) of the control box. 2. Pass the cables through the holes (2) and (3) in the side of the control box. 3. Loosen the screw (5), and then connect the three ground cables (4) that are coming from the machine head. 4. Securely insert each of the connectors (6) - (14) as indicated below. Machine head connectors Connector (6) (12-pin with [1] mark) Connector (7) (5-pin with [2] mark) Connector (8) (9-pin with [3] mark) Connector (9) (12-pin with [4] mark) Connector (10) (5-pin with [6] mark) Connector (11) (5-pin with [7] mark) Connector (12) (16-pin with [8] mark) Connector (13) (18-pin with [9] mark) Connector (14) (10-pin) (Connection indications) * This is indicated on the P.C. board. P1 (ORG) P2 (SYNCHRO) P3 (HEAD) P4 (AIR) P6 (YPM) (BLUE) P7 (XPM) P8 (EXINA) P9 (EXINB) P18 (PANEL) 2998Q PMD circuit Board 5. Insert the connector (15) (6-pin with [1][R] mark) to the connector (16). 6. Loosen the middle screw (19) and then install the ground cable (17) and the three ground cables (18) from the operation panel. 7. Secure the cables with the cable clamp as shown in the illustration. Note: When securing the cables, do not let any of the cables touch the components on the circuit board or the heat sink. Furthermore, adjust the lengths of the cables from outside the control box so that there is no looseness in the cables inside the control box. 2999Q RH-981A 14