Brother International RH-981A Instruction Manual - English - Page 30
Connecting the air tubes, 3-17-7. Securing the air tubes and cables, For chucking cylinder
View all Brother International RH-981A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
3. INSTALLATION 3-17-6. Connecting the air tubes 0855Q Connect air tubes [50], [51], [52] and [53] to the places with the corresponding numbers on the valve unit. Label No. [50], [51] [52] [53] Solenoid valve type For cloth feed drive cylinder For chucking cylinder For holding cylinder 0856Q 3-17-7. Securing the air tubes and cables 3026Q 1. Remove the screw (length 8 mm) (1). 2. Secure the air tube (2) and cable (3) with the cord holder (4), screw (length 16 mm) (5) and washer (6). * Leave enough slack in the air tube (2) and cable (3) at this time to allow for the movement of the feed bracket (7). RH-981A 23
3. INSTALLATION
RH-981A
23
3-17-6. Connecting the air tubes
Connect air tubes [50], [51], [52] and [53] to the places
with the corresponding numbers on the valve unit.
Label No.
Solenoid valve type
[50], [51]
For cloth feed drive cylinder
[52]
For chucking cylinder
[53]
For holding cylinder
3-17-7. Securing the air tubes and cables
1. Remove the screw (length 8 mm) (1).
2. Secure the air tube (2) and cable (3) with the cord holder (4), screw (length 16 mm) (5) and washer (6).
* Leave enough slack in the air tube (2) and cable (3) at this time to allow for the movement of the feed bracket
(7).
0855Q
0856Q
3026Q