Connecting the motor cables, Close the cover 2.
![]() |
View all Brother International RH-981A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
3. INSTALLATION 3-12-2. Connecting the motor cables 1. Remove the screws (1), and then open the terminal block cover (2) of the motor. 2. Loosen the screw (3) and connect the ground cable (4) for the motor. 3. Loosen the screw (5) and connect the ground cable (6) from the control box. 4. Connect the cables so that the cable marks (U, V, W) match the symbols on the screw terminals. 5. Close the cover (2). Note: Be careful not to clamp the cables when closing the cover. 3000Q 3-12-3. Connecting the air tubes Connect the air tubes to the joints of the solenoid valve assembly, using the illustration below as a reference. Numbers are marked on each of the air hoses which come out of the sewing machine. < -00, -01 > 0826Q 0827Q Plug 4 Label No. Solenoid valve 5 Upper thread trimming 4 Upper thread tightening 3 Lower thread trimming *1 2 Cloth spreading (Auxiliary clamp arm *2) 1 Work clamp *1 If the lower thread trimmer is not installed, solenoid valve [3] is not used. *2 The auxiliary clamp arm can only be used for machines with -02 specification. < -02 > 0828Q 15 RH-981A 0829Q