Canon MF6530 Service Manual - Page 146

Procedure after Replacing the Image Processor - download

Page 146 highlights

Chapter 9 9.4.5 Operation Panel Unit 9.4.5.1 Removing the Operation Panel Unit 0011-5460 1) Detach the right cover and inner cover. 2) Detach the delivery tray front cover [1]. 3) Remove the four screws [2]. 4) Pull out the operation panel [3] slightly, and then remove the flexible cable [4]. [4] 6) Disconnect the connector of the cable in the guide [1], remove the claw [2], and slide the guide [1] upward to remove it. 7) Remove the six screws [3]. 8) Remove the screw [4], and then remove the IP cover [5]. When mounting the screw [4], mount it with a grounded plate spring. [3] [2] [5] [3] [3] [1] [3] [1] [3] [2] [3] [3] [4] F-9-20 9) Remove the screw [1], and then remove the ROM PCB [2]. 10) Remove the memory PCB [3]. 11) Disconnect all connectors and flexible cables from the image processor PCB. 12) Remove the six screws [4], and then remove the image processor PCB [5]. [4] [5] [4] [2] F-9-18 9.4.6 Image Processor PCB 9.4.6.1 Removing the Image Processor PCB 0011-5462 1) Detach the rear cover. 2) Remove the modular jack PCB. 3) Disconnect the connector [1], and then release the cable from the clamp. 4) Remove the three screws [2], and then remove the shield [3]. [2] [2] [1] [3] F-9-19 5) Disconnect all connectors from the modem PCB and network PCB. 9-8 [3] [4] [1] [2] [4] F-9-21 9.4.6.2 Procedure after Replacing the Image Processor PCB 0011-5463 If you have replaced the image processor PCB with a new one, perform the following operations: - Using the service support tool, download the latest firmware (System/Boot/ PCL*1) and language files. *1: if equipped with PCL functions - Input the all value printed on the service label affixed to the rear cover. Make the following adjustments: - Correction of output between CS channels 1) Enter the service mode. Sequentially press the Additional functions key, 2 key, 8 key, and Additional functions key on the operation panel. 2) Press the arrow key on the touch panel to display "TEST MODE". 3) Press [OK]. 4) Press the [2] key to display "SCAN TEST". 5) Press the [1] key to display "SHADING". 6) Press [OK]. After completion of the above procedure, the contact sensor output is compensated and parameters are set automatically. After completion of automatic adjustment, "OK" is displayed. - Read position adjustment (Stream reading: Only when the ADF is installed) 1) Enter the service mode. Sequentially press the Additional functions key, 2 key, 8 key, and Additional functions key on the operation panel. 2) Press the arrow key on the touch panel to display "TEST MODE".

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250

Chapter 9
9-8
9.4.5 Operation Panel Unit
9.4.5.1 Removing the Operation Panel Unit
1) Detach the right cover and inner cover.
2) Detach the delivery tray front cover [1].
3) Remove the four screws [2].
4) Pull out the operation panel [3] slightly, and then remove the flexible cable
[4].
F-9-18
9.4.6 Image Processor PCB
9.4.6.1 Removing the Image Processor PCB
1) Detach the rear cover.
2) Remove the modular jack PCB.
3) Disconnect the connector [1], and then release the cable from the clamp.
4) Remove the three screws [2], and then remove the shield [3].
F-9-19
5) Disconnect all connectors from the modem PCB and network PCB.
6) Disconnect the connector of the cable in the guide [1], remove the claw
[2], and slide the guide [1] upward to remove it.
7) Remove the six screws [3].
8) Remove the screw [4], and then remove the IP cover [5].
When mounting the screw [4], mount it with a grounded plate spring.
F-9-20
9) Remove the screw [1], and then remove the ROM PCB [2].
10) Remove the memory PCB [3].
11) Disconnect all connectors and flexible cables from the image processor
PCB.
12) Remove the six screws [4], and then remove the image processor PCB
[5].
F-9-21
9.4.6.2 Procedure after Replacing the Image Processor
PCB
If you have replaced the image processor PCB with a new one, perform the
following operations:
- Using the service support tool, download the latest firmware (System/Boot/
PCL*1) and language files.
*1: if equipped with PCL functions
- Input the all value printed on the service label affixed to the rear cover.
Make the following adjustments:
- Correction of output between CS channels
1) Enter the service mode.
Sequentially press the Additional functions key, 2 key, 8 key, and Additional
functions key on the operation panel.
2) Press the arrow key on the touch panel to display "TEST MODE".
3) Press [OK].
4) Press the [2] key to display "SCAN TEST".
5) Press the [1] key to display "SHADING".
6) Press [OK].
After completion of the above procedure, the contact sensor output is com-
pensated and parameters are set automatically.
After completion of automatic adjustment, "OK" is displayed.
- Read position adjustment (Stream reading: Only when the ADF is installed)
1) Enter the service mode.
Sequentially press the Additional functions key, 2 key, 8 key, and Additional
functions key on the operation panel.
2) Press the arrow key on the touch panel to display "TEST MODE".
[2]
[3]
[2]
[1]
[4]
[2]
[1]
[2]
[3]
[1]
[2]
[3]
[5]
[3]
[3]
[3]
[3]
[4]
[3]
[3]
[1]
[2]
[4]
[4]
[4]
[5]
[4]