Chamberlain B2210T Installation Manual - English Spanish - Page 27

STEP 13 Install the Protector System®, DOOR TRACK INSTALLATION

Page 27 highlights

Installation STEP 13 Install the Protector System® Be sure power is NOT connected to the garage door opener BEFORE installing the safety reversing sensor. To prevent SERIOUS INJURY or DEATH from closing garage door: l Correctly connect and align the safety reversing sensor. This required safety device MUST NOT be disabled. l Install the safety reversing sensor so beam is NO HIGHER than 6" (15 cm) above garage floor. IMPORTANT: The safety reversing sensors MUST be connected and aligned correctly before the garage door opener will move in the down direction. The Protector System® includes two safety reversing sensors which use a light beam to prevent the garage door from closing. The sending sensor (amber LED) transmits the beam to the receiving sensor (green LED) when both are powered and aligned. The receiving sensor has a sticker on the back. If an obstruction breaks the light beam while the door is closing, the door will stop, and reverse to the full open position. When installing the safety reversing sensors, check: l Sensors are installed INSIDE the garage. l Sensor lenses are facing each other. IMPORTANT: Do not allow direct sunlight to the receiving sensor (green LED). l Sensor beam is NO HIGHER than 6" (15 cm) above the floor and the light beam is unobstructed. Hex Screw 10-24 (2) HARDWARE Wing Nut (2) The safety reversing sensors are designed to clip onto the door track with the provided sensor brackets. If the door track will not support the sensor bracket a wall installation is recommended. The sensor beam should be NO HIGHER than 6" (15 cm) above the floor. DOOR TRACK INSTALLATION 1. Slide the curved arms of the sensor bracket around the edge of the door track. Snap into place so that the sensor bracket is flush against the track. 2. Slide the hex screw through the sensor. 3. Attach the sensor to the bracket with the wing nut. Make sure the lens is not obstructed by the bracket. Repeat the steps with the other sensor on the opposite door track. Both lenses must face each other. 1 Door track Garage door 2 3 Safety Reversing Sensor Light Beam Protection Area Safety Reversing Sensor Wing nut 6" (15 cm) max. 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

Be sure power is NOT connected to the garage door opener BEFORE installing the safety reversing sensor.
To prevent SERIOUS INJURY or DEATH from closing garage door:
l
Correctly connect and align the safety reversing sensor. This required safety device MUST NOT be
disabled.
l
Install the safety reversing sensor so beam is NO HIGHER than 6” (15 cm) above garage floor.
Safety Reversing Sensor
Light Beam Protection Area
Safety Reversing Sensor
27
1
2
Hex Screw 10-24 (2)
Garage door
HARDWARE
3
Door track
Wing Nut (2)
Wing nut
6” (15 cm) max.
Installation
STEP 13 Install the Protector System
®
IMPORTANT: The safety reversing sensors MUST be connected and aligned correctly
before the garage door opener will move in the down direction.
The Protector System® includes two safety reversing sensors which use a light beam to prevent the garage door
from closing. The sending sensor (amber LED) transmits the beam to the receiving sensor (green LED) when both
are powered and aligned. The receiving sensor has a sticker on the back. If an obstruction breaks the light beam
while the door is closing, the door will stop, and reverse to the full open position.
When installing the safety reversing sensors, check:
l
Sensors are installed INSIDE the garage.
l
Sensor lenses are facing each other.
IMPORTANT
: Do not allow direct sunlight to the receiving
sensor (green LED).
l
Sensor
beam is NO HIGHER than 6” (15 cm) above the floor and the light beam is unobstructed.
The safety reversing sensors are designed to clip onto the door track with the provided sensor brackets. If the
door track will not support the sensor bracket a wall installation is recommended. The sensor beam should be NO
HIGHER than 6” (15 cm) above the floor.
DOOR TRACK INSTALLATION
1.
Slide the curved arms of the sensor bracket around the edge of the door track. Snap into place so that the
sensor bracket is flush against the track.
2.
Slide the hex screw through the sensor.
3.
Attach the sensor to the bracket with the wing nut. Make sure the lens is not obstructed by the bracket.
Repeat the steps with the other sensor on the opposite door track. Both lenses must face each other.