Compaq dc7100 HP Compaq dc71xx and dx61xx Series Business Desktop Computers Te - Page 45

Specifications, Table 2-6, Environmental Specifications Factory Configuration, Parameter, Operating - cmt specifications

Page 45 highlights

System Overview 2.5 Specifications This section includes the environmental, electrical, and physical specifications for the systems covered in this guide. Where provided, metric statistics are given in parenthesis. Specifications are subject to change without notice. Table 2-6 Environmental Specifications (Factory Configuration) Parameter Operating Non-operating Ambient Air Temperature 50o to 95o F (10o to 35o C, max. rate of change < 10°C/Hr) -24o to 140o F (-30o to 60o C, max. rate of change < 20°C/Hr ) Shock (w/o damage) 5 Gs [1] 20 Gs [1] Vibration 0.000215 G2/Hz, 10-300 Hz 0.0005 G2/Hz, 10-500 Hz Humidity 10-90% Rh @ 28o C max. wet bulb temperature 5-95% Rh @ 38.7o C max. wet bulb temperature Maximum Altitude 10,000 ft (3048 m) [2] 30,000 ft (9144 m) [2] NOTE: [1] [2] Peak input acceleration during an 11 ms half-sine shock pulse. Maximum rate of change: 1500 ft/min. Table 2-7 Electrical Specifications Parameter U.S. Input Line Voltage: Nominal: Maximum: 100-240 VAC 90-264 VAC Input Line Frequency Range: Nominal: Maximum: 50-60 Hz 47-63 Hz Power Supply: Maximum Continuous Power: USDT ST or SFF MT CMT Maximum Line Current Draw: USDT SF or SFF MT CMT 200 watts 240 watts 300 watts [1] 340 watts 4 A @ 100 VAC 5 A @ 100 VAC 8 A @ 100 VAC 6 A @ 100 VAC NOTES: [1] Some MT SKUs shpped with 340-watt power supplies. International 100-240 VAC 90-264 VAC 50-60 Hz 47-63 Hz 200 watts 240 watts 300 watts [1] 340 watts 2 A @ 200 VAC 2.5 A @ 200 VAC 4 A @ 200 VAC 3.0 A @ 200 VAC Technical Reference Guide 361834-002 2-29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

Technical Reference Guide
361834-002
2-29
System Overview
2.5 Specifications
This section includes the environmental, electrical, and physical specifications for the systems
covered in this guide. Where provided, metric statistics are given in parenthesis. Specifications
are subject to change without notice.
NOTE:
[1]
Peak input acceleration during an 11 ms half-sine shock pulse.
[2]
Maximum rate of change: 1500 ft/min.
NOTES:
[1] Some MT SKUs shpped with 340-watt power supplies.
Table 2-6
Environmental Specifications (Factory Configuration)
Parameter
Operating
Non-operating
Ambient Air Temperature
50
o
to 95
o
F (10
o
to 35
o
C, max.
rate of change <
10
°
C/Hr)
-24
o
to 140
o
F (-30
o
to 60
o
C, max.
rate of change <
20
°
C/Hr )
Shock (w/o damage)
5 Gs [1]
20 Gs [1]
Vibration
0.000215 G
2
/Hz, 10-300 Hz
0.0005 G
2
/Hz,
10-500 Hz
Humidity
10-90% Rh @ 28
o
C max.
wet bulb temperature
5-95% Rh @ 38.7
o
C max.
wet bulb temperature
Maximum Altitude
10,000 ft (3048 m) [2]
30,000 ft (9144 m) [2]
Table 2-7
Electrical Specifications
Parameter
U.S.
International
Input Line Voltage:
Nominal:
Maximum:
100–240 VAC
90–264 VAC
100–240 VAC
90–264 VAC
Input Line Frequency Range:
Nominal:
Maximum:
50–60 Hz
47–63 Hz
50–60 Hz
47–63 Hz
Power Supply:
Maximum Continuous Power:
USDT
ST or SFF
MT
CMT
Maximum Line Current Draw:
USDT
SF or SFF
MT
CMT
200 watts
240 watts
300 watts [1]
340 watts
4 A @ 100 VAC
5 A @ 100 VAC
8 A @ 100 VAC
6 A @ 100 VAC
200 watts
240 watts
300 watts [1]
340 watts
2 A @ 200 VAC
2.5 A @ 200 VAC
4 A @ 200 VAC
3.0 A @ 200 VAC