D-Link DGS-1100-08V2 User Manual 1.00 WW - Page 22

From Port, To Port, PoE Configuration, From Port / To Port, State, Priority, Legacy Support

Page 22 highlights

4 Configuration D-Link Smart Managed Switch User Manual 0 Default 1 Optional 2 Optional 3 Optional 4 Optional 15.4W 4.0W 7.0W 15.4W 30W The PoE port table will display the PoE status including, Port Enable, Power Limit, Power (W), Voltage (V), Current (mA), Classification, Port Status. You can select From Port / To Port to control the PoE functions of a port. The DGS-1100-05PDV2/08PV2 will auto disable the ports if port current is over 375mA in 802.3af mode or 625mA in pre-802.3at mode. Note: The PoE Status information of Power current, Power Voltage, and Current is the power usage information of the connected PD; please "Refresh" to renew the information. Figure 4.18 - System > PoE > PoE Configuration The fields that can be configured for PoE Configuration are described below: Item Description From Port / To Port Specifies the PoE function of a port or ports. State Select enable or disable to configure PoE function for designated port(s). Default is Enabled. Priority Configure the power supply priority as "Low", "Normal", or "High" on designated port(s). Default is Normal. (This feature available in DGS-1100-08P only.) Legacy Support Specify to enable or disable detecting legacy PDs signal Power Limit This function allows you to manually set the port power current limitation to be given to the PD. To protect the DGS-110005PDV2/08PV2 and connected devices, the power limit function will disable the PoE function of the port when the power is overloaded. Select from "Class 1", "Class 2", "Class 3", "Class 4" and "Auto" for the power limit. "Auto" will negotiate and follow the classification from the PD power current based on the 802.3at standard. Max. Wattage Check the box and input the power budget (from 1000 to 8000 milliwatts for DGS-1100-05PDV2 and 1000 to 30000 milliwatts for DGS-1100-08PV2) to manually assign an upper limit of port power budget on designated port(s). Table 4.5 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

4
Configuration
D-Link Smart Managed Switch User Manual
19
0
Default
15.4W
1
Optional
4.0W
2
Optional
7.0W
3
Optional
15.4W
4
Optional
30W
The PoE port table will display the PoE status including, Port Enable, Power Limit, Power (W), Voltage (V),
Current (mA), Classification, Port Status. You can select
From Port
/
To Port
to control the PoE functions of
a port. The DGS-1100-05PDV2/08PV2 will auto disable the ports if port current is over 375mA in 802.3af
mode or 625mA in pre-802.3at mode.
Note:
The PoE Status information of Power
current, Power Voltage, and Current is the power
usage information of the connected PD; please
"Refresh" to renew the information.
Figure 4.18 – System > PoE > PoE Configuration
The fields that can be configured for
PoE Configuration
are described below:
Item
Description
From Port / To Port
Specifies the PoE function of a port or ports.
State
Select enable or disable to configure PoE function for
designated port(s). Default is
Enabled.
Priority
Configure the power supply priority as “Low”, “Normal”, or
“High” on designated port(s). Default is
Normal
.
(This feature available in DGS-1100-08P only.)
Legacy Support
Specify to enable or disable detecting legacy PDs signal
Power Limit
This function allows you to manually set the port power current
limitation to be given to the PD. To protect the DGS-1100-
05PDV2/08PV2 and connected devices, the power limit
function will disable the PoE function of the port when the
power is overloaded. Select from "
Class 1
", "
Class 2
", "
Class
3
",
“Class 4”
and "
Auto
" for the power limit. "
Auto
" will
negotiate and follow the classification from the PD power
current based on the 802.3at standard.
Max. Wattage
Check the box and input the power budget (from 1000 to 8000
milliwatts for DGS-1100-05PDV2 and 1000 to 30000 milliwatts
for DGS-1100-08PV2) to manually assign an upper limit of port
power budget on designated port(s).
Table 4.5