D-Link DGS-1100-24P Reference Guide - Page 35

SNTP Settings, System > Time > SNTP Settings

Page 35 highlights

D-Link DGS-1100 Series Switch User Manual Parameter Summer Time State Time Zone Description Select the summer time setting. Options to choose from are Disabled, and Date Setting. Disabled - Select to disable the summer time setting. Date Setting - Select to configure the summer time that should start and end on the specified date. Select to specify your local time zone's offset from Coordinated Universal Time (UTC). The fields that can be configured for Date Setting are described below: Parameter From: Date of the Month From: Month From: Year From: Time (HH:MM) To: Date of the Month To: Month To: Year To: Time (HH:MM) Offset Description Select date of the month that summer time will start. Select the month that summer time will start. Enter the year that the summer time will start. Select the time of the day that summer time will start. Select date of the month that summer time will end. Select the month that summer time will end. Enter the year that the summer time will end. Select the time of the day that summer time will end. Enter the number of minutes to add during summer time. The default value is 60. The range of this offset is 30, 60, 90 and 120. Click the Apply button to accept the changes made. SNTP Settings This window is used to configure the time settings for the Switch. To view the following window, click System > Time > SNTP Settings, as shown below: Figure 5-15 SNTP Settings window The fields that can be configured for SNTP Global Settings are described below: Parameter SNTP State Pool Interval Description Select this option to enable or disable SNTP. Enter the synchronizing interval in seconds. The value is from 30 to 99999 seconds. The default interval is 720 seconds. Click the Apply button to accept the changes made. 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

D-Link DGS-1100 Series Switch User Manual
Parameter
Description
Summer Time State
Select the summer time setting. Options to choose from are
Disabled
, and
Date Setting
.
Disabled
- Select to disable the summer time setting.
Date Setting
- Select to configure the summer time that
should start and end on the specified date.
Time Zone
Select to specify your local time zone’s offset from
Coordinated Universal Time (UTC).
The fields that can be configured for
Date Setting
are described below:
Parameter
Description
From: Date of the Month
Select date of the month that summer time will start.
From: Month
Select the month that summer time will start.
From: Year
Enter the year that the summer time will start.
From: Time (HH:MM)
Select the time of the day that summer time will start.
To: Date of the Month
Select date of the month that summer time will end.
To: Month
Select the month that summer time will end.
To: Year
Enter the year that the summer time will end.
To: Time (HH:MM)
Select the time of the day that summer time will end.
Offset
Enter the number of minutes to add during summer time. The
default value is 60. The range of this offset is 30, 60, 90 and
120.
Click the
Apply
button to accept the changes made.
SNTP Settings
This window is used to configure the time settings for the Switch.
To view the following window, click
System > Time > SNTP Settings
, as shown below:
Figure 5-15 SNTP Settings window
The fields that can be configured for
SNTP Global Settings
are described below:
Parameter
Description
SNTP State
Select this option to enable or disable SNTP.
Pool Interval
Enter the synchronizing interval in seconds. The value is
from 30 to 99999 seconds. The default interval is 720
seconds.
Click the
Apply
button to accept the changes made.
29