D-Link DSN-3400-20 User Guide - Page 67
Advanced Volume Settings, Table 3-1. Advanced Volume Settings
UPC - 790069299773
View all D-Link DSN-3400-20 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
Figure 3-34. Advanced Volume Settings Advanced Setting Table 3-1. Advanced Volume Settings Description Maximum Burst Length First Burst Length Default Time To Wait Default Time To Retain Maximum R2T Outstanding Maximum Connections Maximum length, in bytes, of the SCSI data payload in a sequence of input (DataIn) PDUs or solicited output (Data-Out) PDUs. Default is 262,144 bytes. Maximum amount, in bytes, of unsolicited data that an initiator can send to a target during the execution of a single SCSI command. This amount includes the immediate data, if any, and the sequence of unsolicited Data-Out PDUs, if any, that follow the command. Default is 8192 bytes. Maximum time to wait, in seconds, for a login PDU to be received from the target in response to a login request sent by the initiator before failing the connection attempt. Default is 2 seconds. Length of wait time, in seconds, negotiated between the initiator and the target before trying an explicit/implicit logout or an active task reassignment after an unexpected connection termination or a connection reset. Range is 0 - 3600 seconds. Default is 20 seconds. Maximum number of outstanding ready-to-send (R2T) requests that are allowed for each task within this session. Default is 8. Maximum number of connections that will be allowed within this session. Default is 8. xStack Storage Management Center Software User's Guide 57