Dell Force10 C300 C300 Hardware Installation Guide - Page 27

Installing AC Power Supplies

Page 27 highlights

7 Installing AC Power Supplies The C300 has eight power supply slots at the front-bottom of the chassis (Figure 7-1). The slots accept either AC Power Supply Units (PSUs) or DC Power Entry Modules (PEMs). • Dell Force10 does not support the use of a combination of AC and DC power supplies. • If you select AC, the C300 requires a minimum of two AC power supplies to operate, but Dell Force10 recommends a two-plus-one redundancy configuration, so a minimum of three power supplies is recommended. Additional power supplies are required to enable Power over Ethernet (PoE). See Power Over Ethernet (PoE). • To protect against high-voltage shock, install a power supply blank (CC-C-BLNK-PWR) on all unused power supply slots. • Connect the C300 AC power supply to the appropriate branch circuit protection as defined by local electrical codes. • Verify that the remote power source complies with the system input power specifications in the section System Specifications on page 62 WARNING: The C300 does not have a main disconnect device installed. It is the responsibility of the installer to provide a suitable disconnecting device in the building installation and ensure that it is located/installed near the equipment and is easily accessible. Installing AC Power Supplies | 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

Installing AC Power Supplies
|
27
7
Installing AC Power Supplies
The C300 has eight power supply slots at the front-bottom of the chassis (
Figure
7-
1
). The slots accept
either AC Power Supply Units (PSUs) or DC Power Entry Modules (PEMs).
Dell Force10 does not support the use of a combination of AC and DC power supplies.
If you select AC, the C300 requires a minimum of two AC power supplies to operate, but Dell Force10
recommends a two-plus-one redundancy configuration, so a minimum of three power supplies is
recommended. Additional power supplies are required to enable Power over Ethernet (PoE). See
Power
Over Ethernet (PoE)
.
To protect against high-voltage shock, install a power supply blank (CC-C-BLNK-PWR) on all unused
power supply slots.
Connect the C300 AC power supply to the appropriate branch circuit protection as defined by local
electrical codes.
Verify that the remote power source complies with the system input power specifications in the section
System Specifications on page
62
WARNING:
The C300 does not have a main disconnect device installed. It is the responsibility of the installer
to provide a suitable disconnecting device in the building installation and ensure that it is located/installed near
the equipment and is easily accessible.