Dell Force10 C300 C300 Hardware Installation Guide - Page 60
AC Supplies and Alarms, During system boot, if a redundant supply is removed or fails
View all Dell Force10 C300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
www.dell.com | support.dell.com Table A-1. Alarm Events and Reporting Module Alarm Event Line Card Hardware failure Exceeds high temperature limit Exceeds warning temperature limit Individual interface fails RPM (Non-redundant Configuration with 1 RPM) Exceeds high temperature limit Exceeds warning temperature limit RPM fails but CP is ok Alarm LED major (red) major (red) minor (amber) minor (amber) Reported in event log major major minor reported major (red) minor (amber) major (red) major minor major Status LED on Module amber unlit green amber unlit green amber AC Supplies and Alarms During system boot, if a redundant supply is removed or fails, the FTOS generates a minor alarm message. If only two supplies are installed and one of them fails, the software generates an alarm and an SNMP trap (if configured), and lights the RPM alarm LED and supply LED. 60 | Alarms