Dell Force10 S50-01-GE-48T FTOS 8.4.2.7 Command Line Reference Guide for E-Ser - Page 1576
offline stack-unit
View all Dell Force10 S50-01-GE-48T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1576 highlights
www.dell.com | support.dell.com level1 level2 verbose testname Enter the keyword Level1 to run Level 1 diagnostics. Level 1 diagnostics is a smaller set of diagnostic tests with support for automatic partitioning. They perform status/self test for all the components on the board and test their registers for appropriate values. In addition, they perform extensive tests on memory devices (e.g., SDRAM, flash, NVRAM, EEPROM, and CPLD) wherever possible. There are no tests on 10G links. At this level, stack ports are shut down automatically. Enter the keyword level2 to run Level 2 diagnostics. Level 2 diagnostics is a full set of diagnostic tests with no support for automatic partitioning. Level 2 diagnostics are used primarily for on-board loopback tests and more extensive component diagnostics. Various components on the board are put into loop back mode, and test packets are transmitted through those components. These diagnostics also perform snake tests using VLAN configurations. You must physically remove the unit from the stack to test 10G links. Enter the keyword verbose to run the diagnostic in verbose mode. Verbose mode gives more information in the output than standard mode. Enter the keyword level2 to run a specific test case. Enclose the test case name in double quotes (" "). For example: diag stack-unit 1 level1 testname "first" Defaults Command Modes None EXEC Privilege Command History Version 8.3.1.0 Version 7.7.1.0 Introduced the verbose option. Introduced on S-Series offline stack-unit s Place a stack unit in the offline state. Syntax offline stack-unit number Parameters number Enter the stack unit number. Range: 0 to 7 Defaults None Command Mode EXEC Privilege Command History H Version 8.2.1.0 Version 7.7.1.0 Added warning message to off-line diagnostic Introduced on S-Series Related Commands Usage Information H show environment (S-Series) View S-Series system component status (for example, temperature, voltage). You cannot enter this command on a Master or Standby unit. The system reboots when the off-line diagnostics complete. This is an automatic process. A warning message appears when the offline stack-unit command is implemented. Warning - Diagnostic execution will cause stack-unit to reboot after completion of diags. Proceed with Offline-Diags [confirm yes/no]:y 1576 | S-Series Debugging and Diagnostics