Dell PowerConnect FCS624S Release Notes - Page 50

Defect ID, Technical Severity, Summary, Symptom, Workaround, Feature, Function, Reported In Release

Page 50 highlights

Defect ID: DEFECT000319621 Technical Severity: High Summary: On SX 800/1600 with zero port management module and only SX-48GC line modules, multicast over GRE tunnels is not functional. Symptom: On SX 800/1600 with zero port management module and only SX-48GC line modules, multicast over GRE tunnels is not functional. Workaround: This issue does not happen if the chassis has a non-zero port management module or at least one IPV6 or IPV4 line module. Feature: SX L2/L3 Multicast Features Function: PIM Sparse Reported In Release: FI 07.2.00 Defect ID: DEFECT000266855 Technical Severity: Medium Summary: When reloading a unit, ports on the unit keep "up" to the neighbors. If it is a cross-module trunk, connectivity can be affected. Symptom: The ip interface of the trunk is UP, the OSPF neighbor adjacency may timeout. Workaround: Do not configure a "dead-interval" less than the default 40 seconds, so that the Reload will be completed prior to the expiration of "dead-interval". Or even configure it larger than the default such as 60 seconds. Feature: FCX Layer3 Control Protocols Function: OSPFV2 - IPV4 Reported In Release: FI 06.0.00 Defect ID: DEFECT000269117 Technical Severity: Medium Summary: lldpLocManAddrTable and lldpRemManAddrTable do not display correct IPv4 and IPv6 address. Symptom: lldpLocManAddrTable and lldpRemManAddrTable do not display correct IPv4 and IPv6 address. Feature: FCX Network Management Function: SNMP V4/V6 Reported In Release: FI 07.0.00 Probability: Medium Defect ID: DEFECT000275416 Technical Severity: Medium Summary: Web Management does not force stack priority become after first reload. A second reload is required. Symptom: A second reload is required to change stack priority via web management Feature: FCX Network Management Function: Web Management Reported In Release: FI 07.0.01 Probability: Medium IronWare Software Release 07.2.00a for Brocade FastIron switches Release Notes v 1.0 Page 50 of 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55

IronWare Software Release 07.2.00a for Brocade FastIron switches
Release Notes v 1.0
Page 50 of 55
Defect ID:
DEFECT000319621
Technical Severity:
High
Summary:
On SX 800/1600 with zero port management module and only SX-48GC line modules,
multicast over GRE tunnels is not functional.
Symptom:
On SX 800/1600 with zero port management module and only SX-48GC line modules,
multicast over GRE tunnels is not functional.
Workaround:
This issue does not happen if the chassis has a non-zero port management module or at
least one IPV6 or IPV4 line module.
Feature:
SX L2/L3 Multicast Features
Function:
PIM Sparse
Reported In Release:
FI 07.2.00
Defect ID:
DEFECT000266855
Technical Severity:
Medium
Summary:
When reloading a unit, ports on the unit keep "up" to the neighbors. If it is a cross-module
trunk, connectivity can be affected.
Symptom:
The ip interface of the trunk is UP, the OSPF neighbor adjacency may timeout.
Workaround:
Do not configure a "dead-interval" less than the default 40 seconds, so that the Reload will
be completed prior to the expiration of "dead-interval".
Or even configure it larger than
the default such as 60 seconds.
Feature:
FCX Layer3 Control Protocols
Function:
OSPFV2 - IPV4
Reported In Release:
FI 06.0.00
Defect ID:
DEFECT000269117
Technical Severity:
Medium
Summary:
lldpLocManAddrTable and lldpRemManAddrTable
do not display correct IPv4 and IPv6
address.
Symptom:
lldpLocManAddrTable and lldpRemManAddrTable
do not display correct IPv4 and IPv6
address.
Feature:
FCX Network Management
Function:
SNMP V4/V6
Reported In Release:
FI 07.0.00
Probability:
Medium
Defect ID:
DEFECT000275416
Technical Severity:
Medium
Summary:
Web Management does not force stack priority become after first reload. A second reload is
required.
Symptom:
A second reload is required to change stack priority via web management
Feature:
FCX Network Management
Function:
Web Management
Reported In Release:
FI 07.0.01
Probability:
Medium