Physical Disks, Table 4-1., RAID Controller Physical Disk States, Status, Description, Status LED

Page 38 highlights

Physical Disks Only Dell supported 6.0-Gbps SAS physical disks are supported in the storage array. If the storage array detects unsupported physical disks, it marks the disk as unsupported and the physical disk becomes unavailable for all operations. NOTE: The MD3600i storage enclosure must contain at least two physical disks for proper operation. This is necessary because the physical disks are used to store configuration information. Physical Disk States Table 4-1 describes the various states of the physical disk, which are recognized by the storage array and reported in the MDSM application. Table 4-1. RAID Controller Physical Disk States Status Mode Description Physical Disk Status LED Optimal Assigned The physical disk in the indicated slot Steady green is configured as part of a disk group. Optimal Unassigned The physical disk in the indicated slot Steady green is unused and available to be configured. Optimal Hot Spare Standby The physical disk in the indicated slot Steady green is configured as a hot spare. Optimal Hot Spare in use The physical disk in the indicated slot Steady green is in use as a hot spare within a disk group. Failed Assigned, The physical disk in the indicated slot Amber flashing Unassigned, has failed because of an unrecoverable (150 ms) Hot Spare in error, an incorrect drive type or drive use, or Hot size, or by its operational state being Spare Standby set to failed. Replaced Assigned The physical disk in the indicated slot Green flashing has been replaced and is ready to be, (on 400 ms, off or is actively being, configured into a 100 ms) disk group. 38 Planning: MD3600i Series Storage Array Terms and Concepts

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282

38
Planning: MD3600i Series Storage Array Terms and Concepts
Physical Disks
Only Dell supported 6.0-Gbps SAS physical disks are supported in the storage
array. If the storage array detects unsupported physical disks, it marks the disk
as unsupported and the physical disk becomes unavailable for all operations.
NOTE:
The MD3600i storage enclosure must contain at least two physical disks for
proper operation. This is necessary because the physical disks are used to store
configuration information.
Physical Disk States
Table 4-1 describes the various states of the physical disk, which are
recognized by the storage array and reported in the MDSM application.
Table 4-1.
RAID Controller Physical Disk States
Status
Mode
Description
Physical Disk
Status LED
Optimal
Assigned
The physical disk in the indicated slot
is configured as part of a disk group.
Steady green
Optimal
Unassigned
The physical disk in the indicated slot
is unused and available to be
configured.
Steady green
Optimal
Hot Spare
Standby
The physical disk in the indicated slot
is configured as a hot spare.
Steady green
Optimal
Hot Spare in
use
The physical disk in the indicated slot
is in use as a hot spare within a disk
group.
Steady green
Failed
Assigned,
Unassigned,
Hot Spare in
use, or Hot
Spare Standby
The physical disk in the indicated slot
has failed because of an unrecoverable
error, an incorrect drive type or drive
size, or by its operational state being
set to failed.
Amber flashing
(150 ms)
Replaced
Assigned
The physical disk in the indicated slot
has been replaced and is ready to be,
or is actively being, configured into a
disk group.