Epson U01II User Manual - Page 119

Level = OPOS_CH_INTERACTIVE., InputBuf edit field, Output Interval Time edit field

Page 119 highlights

Version 2.65 Jul. 2009 If the port selection is parallel, USB, or "None", then this combo box cannot be used to change the setting. "InputBuf" edit field This edit field supports only Version 1.xx devices. Use this edit field to display and set the input buffer size of the serial port. The acceptable range is 32 to 8192. For details, refer to the hardware manual of the device. If the port selection is parallel, USB, or "None", then this edit field cannot be used to change the setting. "OutputBuf" edit field Use this edit field to display and set the output buffer size of the serial or parallel port. The acceptable range is 32 to 1024, but restrictions apply to some devices depending on the device information file (INF). This setting is valid for parallel port, and it is possible to specify the size of data to output. For details, refer to the hardware manual of the device. If the port selection is USB or "None", then this edit field cannot be used to change the setting. "Output Interval Time" edit field Use this edit field for set the retry time to use when output fails. For details of output interval time, please refer to the "5.8 Glossary" of this manual. The acceptable range is 0 to 9999. For details, refer to the hardware manual of the device. If the port setting is "None", this field cannot be used to change the setting. "Input SleepTime" edit field This edit field supports only Version 1.xx devices. Use this edit field to display and set the sleep time to use by the Sleep API in input. The acceptable range is 0 to 99. For details, refer to the hardware manual of the device. If the port selection is USB or "None", then this edit field cannot be used to change the setting. [CheckHealth Interactive] button Use this button to call the CheckHealth method for the selected device using Level = OPOS_CH_INTERACTIVE. 114 User's Manual Installer, SetupPOS, TMUSB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

Version 2.65
Jul. 2009
114
User's Manual
Installer, SetupPOS, TMUSB
If the port selection is parallel, USB, or "None", then this combo box cannot be
used to change the setting.
"InputBuf" edit field
This edit field supports only Version 1.xx devices.
Use this edit field to display and set the input buffer size of the serial port.
The acceptable range is 32 to 8192.
For details, refer to the hardware manual of the device.
If the port selection is parallel, USB, or "None", then this edit field cannot be used
to change the setting.
"OutputBuf" edit field
Use this edit field to display and set the output buffer size of the serial or parallel
port.
The acceptable range is 32 to 1024, but restrictions apply to some devices
depending on the device information file (INF).
This setting is valid for parallel port, and it is possible to specify the size of data to
output.
For details, refer to the hardware manual of the device.
If the port selection is USB or "None", then this edit field cannot be used to
change the setting.
"Output Interval Time" edit field
Use this edit field for set the retry time to use when output fails. For details of
output interval time, please refer to the "5.8 Glossary
" of this manual. The
acceptable range is 0 to 9999. For details, refer to the hardware manual of the
device.
If the port setting is "None", this field cannot be used to change the setting.
"Input SleepTime" edit field
This edit field supports only Version 1.xx devices.
Use this edit field to display and set the sleep time to use by the Sleep API in
input.
The acceptable range is 0 to 99.
For details, refer to the hardware manual of the device.
If the port selection is USB or "None", then this edit field cannot be used to
change the setting.
[CheckHealth Interactive] button
Use this button to call the CheckHealth method for the selected device using
Level = OPOS_CH_INTERACTIVE.