Epson U01II User Manual - Page 96

Usually, select Open, Claim&Enable recommended., For Open, Claim

Page 96 highlights

Version 2.65 Jul. 2009 At this moment, DataEvent is not sent. Afterwards, when DeviceEnabled is set to TRUE, DataEvent is sent. (AutoDisable UPOS specifications) For "Open, Claim": Immediately after SO receives the data notified as DataEvent, DeviceEnabled is set to FALSE. At this moment, DataEvent is sent (EPSON specific specifications). Usually, select "Open, Claim&Enable" (recommended). To upgrade OPOS ADK from version 1.5x or earlier and enable the existing applications to run in the new version without any modification, use "Open, Claim". The specifications for operations are different in pre-Ver2.60 and Ver2.60. Select which specification. These are settable only for the EPSON OPOS ADK of the starting from Ver2.60. (3) When the specification starting from OPOS Ver2.60: The specifications for the initialization, devices with hydra connection, and Error Event are operated in compliance with UPOS1.11. (UPOS Specification) (4) When the specifications prior to OPOS Ver2.60: The specifications for the initialization, devices with hydra connection, and Error Event are operated in compliance with the specifications Pre-Ver2.60. (EPSON Specification) The default setting is different by the condition. Condition Without the installation of EPSON OPOS ADK in advance When the prior to Version 2.60 of EPSON OPOS ADK already has been installed Default setting Ver2.60 specification Pre-Ver2.60 specification The target categories are as follows: POSPrinter LineDisplay CashDrawer (ElectronicJournal) 91 User's Manual Installer, SetupPOS, TMUSB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

Version 2.65
Jul. 2009
91
User's Manual
Installer, SetupPOS, TMUSB
At this moment, DataEvent is not sent. Afterwards, when DeviceEnabled
is set to TRUE, DataEvent is sent.
(AutoDisable UPOS specifications)
For "Open, Claim":
Immediately after SO receives the data notified as DataEvent,
DeviceEnabled is set to FALSE.
At this moment, DataEvent is sent (EPSON specific specifications).
Usually, select "Open, Claim&Enable" (recommended).
To upgrade OPOS ADK from version 1.5x or earlier and enable the
existing applications to run in the new version without any modification,
use "Open, Claim”.
The specifications for operations are different in pre-Ver2.60 and
Ver2.60. Select which specification. These are settable only for the
EPSON OPOS ADK of the starting from Ver2.60.
(3)
When the specification starting from OPOS Ver2.60:
The specifications for the initialization, devices with hydra
connection, and Error Event are operated in compliance with
UPOS1.11.
(UPOS Specification)
(4)
When the specifications prior to OPOS Ver2.60:
The specifications for the initialization, devices with hydra
connection, and Error Event are operated in compliance with the
specifications Pre-Ver2.60.
(EPSON Specification)
The default setting is different by the condition.
Condition
Default setting
Without the installation of EPSON OPOS ADK in
advance
Ver2.60
specification
When the prior to Version 2.60 of EPSON OPOS
ADK already has been installed
Pre-Ver2.60
specification
The target categories are as follows:
<Initialization processing>
POSPrinter
LineDisplay
CashDrawer
(ElectronicJournal)