Fluke 225C User Manual - Page 133

Zoom, Replay and Cursors, Fieldbus - Bushealth, Replay, Cursor Measurements

Page 133 highlights

Zoom, Replay and Cursors Zoom Horizontal Magnification Scope Record up to 120x TrendPlot up to 96x Scope up to 8x Replay Displays a maximum of 100 captured dual input Scope screens. Replay modes Step by Step, Replay as Animation Cursor Measurements Cursor Modes single vertical cursor dual vertical cursors dual horizontal cursors (Scope mode) Markers automatic markers at cross points Measurements value at cursor 1 value at cursor 2 difference between values at cursor 1 and 2 time between cursors, RMS between cursors Time of Day (Recorder modes) Time from Start (Recorder modes) Rise Time 10 Specifications Zoom, Replay and Cursors Fieldbus - Bushealth Type AS-i CAN Modbus Foundation Fieldbus Profibus Ethernet RS-232 RS-485 Subtype RS-232 RS-485 H1 Protocol NEN-EN50295 ISO-11898-2 RS-232/EIA-232 RS-485/EIA-485 61158 type 1, 31.25 kBit/s DP PA Coax TP TP EIA-485 61158 type 1 10Base2 10BaseT 100BaseT EIA-232 EIA-485 123

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159

Specifications
Zoom, Replay and Cursors
10
123
Zoom, Replay and Cursors
Zoom
Horizontal Magnification
Scope Record
..............................................
up to 120x
TrendPlot
........................................................
up to 96x
Scope
................................................................
up to 8x
Replay
Displays a maximum of 100 captured dual input Scope
screens.
Replay modes
...........
Step by Step, Replay as Animation
Cursor Measurements
Cursor Modes
..................................
single vertical cursor
dual vertical cursors
dual horizontal cursors (Scope mode)
Markers
.......................
automatic markers at cross points
Measurements
.......................................
value at cursor 1
value at cursor 2
difference between values at cursor 1 and 2
time between cursors,
RMS between cursors
Time of Day (Recorder modes)
Time from Start (Recorder modes)
Rise Time
Fieldbus – Bushealth
Type
Subtype
Protocol
AS-i
NEN-EN50295
CAN
ISO-11898-2
Modbus
RS-232
RS-485
RS-232/EIA-232
RS-485/EIA-485
Foundation
Fieldbus
H1
61158 type 1, 31.25 kBit/s
Profibus
DP
PA
EIA-485
61158 type 1
Ethernet
Coax
TP
TP
10Base2
10BaseT
100BaseT
RS-232
EIA-232
RS-485
EIA-485