Fluke 225C User Manual - Page 95
Deleting Screens with Associated Setups, View/Delete
View all Fluke 225C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 95 highlights
6 Select another character. Repeat 5 and 6 until done. 7 Save the actual screen. To use the default name generated by the test tool, continue from step 4 as follows: 5 Use default name. 6 Save the actual screen. Notes The two record+setup memory locations store more than what is just visible on the screen. In TrendPlot or scope record mode the full recording is saved. In scope mode you can save all 100 replay screens in a single record+setup memory location. The table below shows what you can store for the various test tool modes. To save a Trendplot press STOP first. 7 Using Memory, PC and Printer Saving and Recalling Mode METER SCOPE SCOPE REC TRENDPLOT BUSHEALTH Memory locations 15x 'screen+setup' 2x 'record+setup' setup+1screen N/A setup+1screen setup+100 replay screens setup setup+record data setup setup+trendplot data setup+1 screen *) N/A *) in eye pattern mode and persistence mode the most recently written trace will be saved, not all persistence traces. Deleting Screens with Associated Setups To delete a screen and associated setup, do the following: 1 Display the SAVE/PRINT key labels. 2 Open the View/Delete menu. 3 Highlight a screen+setup 4 Delete the saved screen+setup. 85