Fluke 225C User Manual - Page 152

Modbus IEA-232/RS-232., Is in use in Process Industry, Building and Factory

Page 152 highlights

Modbus IEA-232/RS-232. Is in use in Process Industry, Building and Factory Automation. Modbus RS-232 is used for point-to-point communication. System layout is shown in the figure below. Continuous data traffic is not ensured. CONTROLLER TxD RxD GND DEVICE UNDER CONTROL Modbus IEA-232/-RS-232 To check this type of bus, ScopeMeter Channel A is on and DC coupled. The recommended probe is the Fluke 10:1 probe. Connect the probe as shown below. TxD or RxD GND In case there are handshake lines, they can be measured as well as far as V-Levels are concerned. A Appendices Bushealth Measurements Modbus IEA-485/RS-485. Is in use in Process Industry, Building and Factory Automation. Modbus System layout is shown in the figure below. Continuous data traffic is not ensured. CONTROLLER DATA + DATA GND DEVICE 1 DEVICE 2 Modbus IEA-485/-RS-485 To check this type of bus, ScopeMeter Channel A and B are on and DC coupled. The recommended probes are Fluke 10:1 probes. Connect the probes as shown below. DATA + DATA DATA GND A-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159

Appendices
Bushealth Measurements
A
A-5
Modbus IEA-232/RS-232.
Is in use in Process Industry, Building and Factory
Automation. Modbus RS-232 is used for point-to-point
communication. System layout is shown in the figure
below. Continuous data traffic is not ensured.
CONTROLLER
DEVICE UNDER
CONTROL
TxD
RxD
GND
Modbus IEA-232/-RS-232
To check this type of bus, ScopeMeter Channel A is on
and DC coupled. The recommended probe is the Fluke
10:1 probe. Connect the probe as shown below.
TxD or RxD
GND
In case there are handshake lines, they can be measured
as well as far as V-Levels are concerned.
Modbus IEA-485/RS-485.
Is in use in Process Industry, Building and Factory
Automation. Modbus System layout is shown in the figure
below. Continuous data traffic is not ensured.
CONTROLLER
DEVICE 1
DEVICE 2
DATA +
DATA -
GND
Modbus IEA-485/-RS-485
To check this type of bus, ScopeMeter Channel A and B
are on and DC coupled. The recommended probes are
Fluke 10:1 probes.
Connect the probes as shown below.
DATA +
DATA -
DATA GND