3) MFG_F_JP1 (ME Recovery Jumper) 1 1-2 Close: Enable ME recovery. (Default setting) 1 2-3 Close: Disable ME recovery. 4) PWD_JP1 (Clear Password Jumper) Use this jumper to clear the supervisor password. 1 1-2 Close: Normal operation (Default setting) 1 2-3 Close: Clear password. - 27 - Hardware Installation
- 27 -
Hardware Installation
4)
PWD_JP1 (Clear Password Jumper)
Use this jumper to clear the supervisor password.
1-2 Close: Normal operation (Default setting)
2-3 Close: Clear password.
1
1
3)
MFG_F_JP1 (ME Recovery Jumper)
1-2 Close: Enable ME recovery. (Default setting)
2-3 Close: Disable ME recovery.