XML Object Name, Description, Access, HP Monitored PDU User's Guide, P-164000281-Rev 1
View all HP 11kVA 400 Volt IEC309 16A 3-Phase Input 18xC13/3xC19 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
Table 9. PDU CLI Objects (Continued) XML Object Name PDU.Gang[x].Current PDU.Gang[x].GangID PDU.Gang[x].iGang PDU.Gang[x].iName PDU.Gang[x].InputID PDU.Gang[x].OverCurrent[1].Threshold PDU.Gang[x].OverCurrent[3].Threshold PDU.Gang[x].OverCurrent[4].Threshold PDU.Gang[x].OverVoltage[1].Threshold PDU.Gang[x].OverVoltage[2].Threshold PDU.Gang[x].OverVoltage[3].Threshold PDU.Gang[x].OverVoltage[4].Threshold PDU.Gang[x].PeakFactor PDU.Gang[x].PercentLoad PDU.Gang[x].PhaseID PDU.Gang[x].Pole[1].ActivePower PDU.Gang[x].Pole[1].ApparentPower PDU.Gang[x].Pole[1].Current PDU.Gang[x].Pole[1].PeakFactor PDU.Gang[x].Pole[1].PhaseID PDU.Gang[x].Pole[1].PowerFactor PDU.Gang[x].Pole[1].ReactivePower PDU.Gang[x].Pole[1].Statistic[4].Energy PDU.Gang[x].Pole[1].Voltage PDU.Gang[x].Pole[2].ActivePower PDU.Gang[x].Pole[2].ApparentPower PDU.Gang[x].Pole[2].Current PDU.Gang[x].Pole[2].PeakFactor PDU.Gang[x].Pole[2].PhaseID PDU.Gang[x].Pole[2].PowerFactor Serial Interface Operation Type Measure Constant String[15] String[31] Constant Parameter Parameter Parameter Parameter Parameter Parameter Parameter Measure Measure Constant HideMeasure HideMeasure HideMeasure HideMeasure Constant HideMeasure HideMeasure HideMeasure HideMeasure HideMeasure HideMeasure HideMeasure HideMeasure Constant HideMeasure Description Unit Access Current provided by the breaker/section. For a double pole mA RO breaker, it is calculated as the max of the two poles current. Breaker ID = x(1,2,..) - RO Breaker/section silk-screened name. - RO Example: 'A' or 'B' .... Breaker/section friendly name. - RW Identify which Input is powering the group. This is useful - RO when the PDI is dual Input. mA RW mA RW mA RW Threshold cV RW Threshold cV RW Threshold cV RW Threshold cV RW Crest factor of the current provided by the breaker/section. m% RO A double pole breaker is calculated as the max of the two poles crest factor. Percent load consumed by the breaker/section. It is the ratio: current consumed / the nominal current. % RO Phase number that is connected to the breaker/section: 1, - RO 2, or 3. A double pole breaker is ij. Ex: 12 if the 2 phases are L1 and L2. Active Power provided by the pole. dW RO Apparent Power provided by the pole. dVA RO Current provided by the pole. mA RO Crest factor of the current provided by the pole. m% RO Phase number that is connected to the pole: 1, 2, or 3. - RO Ratio of active power / apparent power provided by the pole of the breaker or outlet section. m% RO Reactive Power provided by the pole. dVA RO R Energy counter since last reset. As it is reset to 0, the Wh RO related timestamp is updated with the current RTC value. Voltage Measured on the pole. cV RO Active Power provided by the pole. dW RO Apparent Power provided by the pole. dVA RO Current Power provided by the pole. mA RO Crest factor of the current provided by the pole. m% RO Phase number that is connected to the pole: 1, 2, or 3. - RO Ratio of active power / apparent power provided by the pole of the breaker or outlet section. m% RO HP Monitored PDU User's Guide P-164000281-Rev 1 84