Page 93 highlights
Serial Interface Operation Table 9. PDU CLI Objects (Continued) XML Object Name PDU.Input[1].Phase[x].PresentStatus.OverCurrent PDU.Input[1].Phase[x].PresentStatus.OverVoltage PDU.Input[1].Phase[x].ReactivePower PDU.Input[1].Phase[x].Statistic[4].Energy PDU.Input[1].Phase[x].Statistic[4].ModuleReset PDU.Input[1].Phase[x].Statistic[4].Reset.Energy PDU.Input[1].Phase[x].Statistic[4].Reset.Time PDU.Input[1].Phase[x].Voltage PDU.Input[1].PowerFactor PDU.Input[1].PresentStatus.FrequencyOutOfRange PDU.Input[1].ReactivePower PDU.Input[1].Statistic[3].ActivePower PDU.Input[1].Statistic[3].ModuleReset PDU.Input[1].Statistic[3].Reset.Time PDU.Input[1].Statistic[3].Time PDU.Input[1].Statistic[4].Energy PDU.Input[1].Statistic[4].ModuleReset Type AlarmL1 AlarmL1 HideMeasure HideMeasure Command HideMeasure HideMeasure Measure Measure AlarmL1 Measure Measure Command Measure Measure Measure Command Description Unit Access 0: No threshold triggered - RO 1: Warning low threshold triggered 2: Critical low threshold triggered 3: Warning high threshold triggered 4: Critical high threshold triggered 0: No threshold triggered - RO 1: Warning low threshold triggered 2: Critical low threshold triggered 3: Warning high threshold triggered 4: Critical high threshold triggered Reactive Power Measurement. dVA RO R Energy counter since last reset. As it is reset to 0, the Wh RO related timestamp is updated with the current RTC value. - RW Energy counter saved at last reset. As it is reset, the related timer updated with PDU timer since 1st restart. Wh RO Timestamp saved at the moment when the related energy s RO counter is reset. Voltage Measurement. cV RO Ratio of active power / apparent power provided by the input. m% RO Value 0 to 100 for Cos PHI = 0.00 to 1.00 0: Frequency OK - RO 1: Frequency is out of +/- 3Hz tolerance Reactive Power Measurement. It is the accumulation of 1 or 3 phase measures. dVA RO R Power peak consumption since last reset. dW RO As it is reset to 0, the related timestamp is updated with the current RTC value. When a value higher than the stored value is detected, the stored valued is overwritten. Command to Reset the stat. This command puts 0 in the - RW max and saves the current value of Timer into the data ...Timer and into ...Reset.Timer. Timestamp saved at the moment when the statistic is reset. s RO Timestamp saved at the moment when the statistic is reset. s RO Energy counter since last reset. As it is reset to 0, the Wh RO related timestamp is updated with the current RTC value. It combines the energy consumed on 1 or 3 phases. Command to Reset the stat. This command does not put 0 s RW in the counter, but it saves the current value of Energy timer into the data ...Reset.Energy. HP Monitored PDU User's Guide P-164000281-Rev 1 87