HP 11kVA HP Monitored Power Distribution Unit User Guide - Page 88
XML Object Tables, Table 9. PDU CLI Objects
![]() |
View all HP 11kVA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
Serial Interface Operation XML Object Tables This section includes tables that define PDU CLI objects (Table 9) and System CLI Objects (Table 10 on page 90). Table 9. PDU CLI Objects XML Object Name Environment.ChangedStatus.CommunicationLost Environment.ChangedStatus.OverHumidity Environment.ChangedStatus.OverTemperature Environment.Humidity Environment.Input[1].ChangedStatus.Alarm Environment.Input[1].iName Environment.Input[1].PresentStatus.Alarm Environment.Input[1].PresentStatus.State Environment.Input[1].State[0].Level Environment.Input[1].State[1].Level Environment.Input[2].ChangedStatus.Alarm Environment.Input[2].iName Environment.Input[2].PresentStatus.Alarm Environment.Input[2].PresentStatus.State Type Timestamp Timestamp Timestamp Measure Timestamp String[31] AlarmL1 Measure Parameter Parameter Timestamp String[31] AlarmL1 Measure Description Unit Access Timestamp of last changing state of the alarm that has the s RO same name in the collection PresentStatus. Timestamp of last changing state of the alarm that has the s RO same name in the collection PresentStatus. Timestamp of last changing state of the alarm that has the s RO same name in the collection PresentStatus. Measured Humidity on environmental monitoring probe. d% RO 0 when no probe is connected or when the probe does not have a humidity sensor. Timestamp of last changing state of the alarm that has the s RO same name in the collection PresentStatus. Contact 1 friendly name - RW Dry Contact alarm. Set according to the dry contact State - RO and the parameter State[0] or [1].Level 0: Alarm not active 1: Alarm active Ex: State=0 AND State[0].Level=3 then Alarm=1 Dry Contact state - RO 0: Open 1: Close Dry contact Config - RW 1: Open makes just informational 0 into State. 2: Open makes Warning trap 3: Open makes Alarm trap Dry contact Config - RW 1: Close makes just informational 0 into State. 2: Close makes Warning trap 3: Close makes Alarm trap Timestamp of last changing state of the alarm that has the s RO same name in the collection PresentStatus. Contact 2 friendly name - RW Dry Contact alarm. Set according to the dry contact State - RO and the parameter State[0] or [1].Level 0: Alarm not active 1: Alarm active Ex: State=0 AND State[0].Level=3 then Alarm=1 Dry Contact state - RO 0: Open 1: Close HP Monitored PDU User's Guide P-164000281-Rev 1 82
![](/manual_guide/products/hewlettpackard-36kva-hp-monitored-power-distribution-unit-user-guide-9f24a2e/88.png)