HP 11kVA HP Monitored Power Distribution Unit User Guide - Page 89
Table 9. PDU CLI Objects Continued, XML Object Name, Description, Access
View all HP 11kVA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
Table 9. PDU CLI Objects (Continued) XML Object Name Environment.Input[2].State[0].Level Environment.Input[2].State[1].Level Environment.OverHumidity[1].Threshold Environment.OverHumidity[2].Threshold Environment.OverHumidity[3].Threshold Environment.OverHumidity[4].Threshold Environment.OverTemperature[1].Threshold Environment.OverTemperature[2].Threshold Environment.OverTemperature[3].Threshold Environment.OverTemperature[4].Threshold Environment.PresentStatus.CommunicationLost Environment.PresentStatus.OverHumidity Environment.PresentStatus.OverTemperature Environment.Temperature PDU.Gang.Count PDU.Gang[x].ActivePower PDU.Gang[x].ApparentPower PDU.Gang[x].ChangedStatus.OverCurrent PDU.Gang[x].ChangedStatus.OverVoltage PDU.Gang[x].ConfigCurrent Serial Interface Operation Type Parameter Parameter Parameter Parameter Parameter Parameter Parameter Parameter Parameter Parameter AlarmL1 AlarmL1 AlarmL1 Measure Constant Measure Measure Timestamp Timestamp Constant Description Unit Access Dry contact Config - RW 1: Open makes just informational 0 into State. 2: Open makes Warning trap. 3: Open makes Alarm trap. Dry contact Config - RW 1: Close makes just informational 0 into State. 2: Close makes Warning trap. 3: Close makes Alarm trap. d% RW d% RW d% RW d% RW d°K RW d°K RW d°K RW d°K RW 0: OK - RO 1: Communication failure with the sensor probe or probe not present. 0: No threshold triggered - RO 1: Warning low threshold triggered 2: Critical low threshold triggered 3: Warning high threshold triggered 4: Critical high threshold triggered 0: No threshold triggered - RO 1: Warning low threshold triggered 2: Critical low threshold triggered 3: Warning high threshold triggered 4: Critical high threshold triggered Measured Temperature on environmental monitoring probe. d°K RO It is 0 when no probe is connected. Number of factory groups in the PDU. - RO Active Power provided by the breaker/section. For a double dW RO pole breaker, the apparent power for the two poles is combined. Apparent Power provided by the breaker/section. For a dVA RO double pole breaker, the apparent power for the two poles is combined. s RO s RO Nominal Amps: 10A, 16A, 20A, .. mA RO This is useful for both breaker and outlet section. HP Monitored PDU User's Guide P-164000281-Rev 1 83