HP Dc5850 Technical Reference Guide: HP Compaq dc5850 Series Business Desktop - Page 26
Specifications - sff power supply
UPC - 884962022993
View all HP Dc5850 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
System Overview 2.4 Specifications This section includes the environmental, electrical, and physical specifications for the systems covered in this guide. Where provided, metric statistics are given in parenthesis. Specifications are subject to change without notice. Table 2-5 Environmental Specifications (Factory Configuration) Parameter Operating Non-operating Ambient Air Temperature 50o to 95o F (10o to 35o C, max. rate of change < 10°C/Hr) -22o to 140o F (-30o to 60o C, max. rate of change < 20°C/Hr) Shock (w/o damage) 5 Gs [1] 20 Gs [1] Vibration 0.000215 G2/Hz, 10-300 Hz 0.0005 G2/Hz, 10-500 Hz Humidity 10-90% Rh @ 28o C max. wet bulb temperature 5-95% Rh @ 38.7o C max. wet bulb temperature Maximum Altitude 10,000 ft (3048 m) [2] 30,000 ft (9144 m) [2] NOTE: [1] [2] Peak input acceleration during an 11 ms half-sine shock pulse. Maximum rate of change: 1500 ft/min. Table 2-6 Power Supply Electrical Specifications Parameter Value Input Line Voltage: Nominal: Maximum 100-240 VAC 90-264 VAC Input Line Frequency Range: Nominal Maximum 50-60 Hz 47-63 Hz Energy Star 4.0 with 80Plus Bronze-level compliancy SFF MT Optional Optional Maximum Continuous Power: SFF MT 240 watts 300 watts NOTE: Optional Energy Star 4.0 with 80-Plus Bronze-level compliant power supply unit available for both form factors. 2-10 www.hp.com Technical Reference Guide