HP Dc5850 Technical Reference Guide: HP Compaq dc5850 Series Business Desktop - Page 62
USB Cable Data
UPC - 884962022993
View all HP Dc5850 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
Input/Output Interfaces 5.7.2 USB Cable Data The recommended cable length between the host and the USB device should be no longer than sixteen feet for full-channel (12 MB/s) operation, depending on cable specification (see following table). Table 5-8. USB Cable Length Data Conductor Size Resistance Maximum Length 20 AWG 0.036 Ω 16.4 ft (5.00 m) 22 AWG 0.057 Ω 9.94 ft (3.03 m) 24 AWG 0.091 Ω 6.82 ft (2.08 m) 26 AWG 0.145 Ω 4.30 ft (1.31 m) 28 AWG 0.232 Ω 2.66 ft (0.81 m) NOTE: For sub-channel (1.5 MB/s) operation and/or when using sub-standard cable shorter lengths may be allowable and/or necessary. The shield, chassis ground, and power ground should be tied together at the host end but left unconnected at the device end to avoid ground loops. Table 5-9. USB Color Code Signal Insulation color Data + Green Data - White Vcc Red Ground Black 5-12 www.hp.com Technical Reference Guide