HP Indigo ws4500 Rewinder Service - Page 11
At the TSP, Calibrating the ultrasonic sensor
View all HP Indigo ws4500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
4. Manually rotate the dancer clockwise until it is at an angle of approximately +40°. At the TSP Calibration at the TSP. Press the button for more than two seconds. The dancer may rotate slightly and stop exactly at the angle +40°. Calibrating the ultrasonic sensor Ultrasonic sensor calibration. 1. Select Roll Diameter window by pressing the next page icon . 2. Measure the diameter of the empty core, and enter the value in the Small diameter Setup field. 8 Chapter 2 Procedures
4.
Manually rotate the dancer clockwise until it is at an angle of approximately +40°.
At the TSP
Calibration at the TSP.
Press the button
for more than two seconds.
The dancer may rotate slightly and stop exactly at the angle +40°.
Calibrating the ultrasonic sensor
Ultrasonic sensor calibration.
1.
Select Roll Diameter window by pressing the next page icon
.
2.
Measure the diameter of the empty core, and enter the value in the
Small diameter Setup
field.
8
Chapter 2
Procedures