HP LC2000r HP Netserver LC 2000 Installation Guide - Page 86
Refer to Opening and Closing the HP NetServer,
View all HP LC2000r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
Chapter 7 2nd VRM Installing Additional Processors VRM Latches Figure 7-6. Installing VRM CAUTION To prevent damage to the VRM, do not push on the large flat surface or touch the components on the board as you push the VRM card down into the slot. Push only on the edges of the VRM board. 15. Open the VRM retaining latches as shown in Figure 7-6. 16. Align the VRM's connector edge with the secondary VRM slot. See Figure 7-6. The VRM's component side should face towards the center of the enclosure, which is just the opposite of the primary VRM already installed. 17. Gently push as you insert the VRM into the socket. See Figure 7-6. 18. Re-install the cover on the processor cage by reversing Step 8. 19. Re-install the cover and bezel onto the NetServer according to the appropriate procedure. Refer to Chapter 3, "Opening and Closing the HP NetServer," for instructions. 20. Return power to the NetServer and restore normal operation. 78