HP LH4r HP Netserver LH 3/LH 3r to LH 4/LH 4r - Page 35

Update the Operating System

Page 35 highlights

Chapter 4 Updating Firmware CAUTION This Embedded NetRAID update only updates the firmware on the CPU baseboard. When you reboot the NOS after this update, you will get an error message caused by conflicts between the NetRAID information stored elsewhere in the system and the new information saved in the CPU baseboard firmware. Use the HP NetRAID Express Tools utility to reconfigure your system, based on the configuration details you documented before starting the upgrade. 10. Enter the Setup utility by pressing F2 at the screen prompt. Run "Clear Config" to clear the SCSI Controller, Embedded RAID, and system configuration. NOTE If you do not push F2 quickly enough, you may be immediately routed to the HP NetRAID Express Tools utility to remedy the problem noted in the above CAUTION. Perform the Embedded RAID reconfiguration, then proceed to the Setup reconfiguration. 11. Reconfigure Embedded RAID and Setup according to the configuration you saved earlier. You should not need to reinitialize the hard disks. 12. Reboot the system and: A. Reconfigure Integrated Remote Assistant B. Clear the System Event Log Update the Operating System NOTE If you are upgrading from a single-processor to multi-processor machine, you may have to reinstall the operating system. Please consult with your operating system vendor. WARNING Navigator will prompt the user, "Would you like to use HP's automated mode of NOS Installation?" The default is "Yes." If you choose "Yes," whatever was on the C: drive will be lost. 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Chapter 4
Updating Firmware
31
CAUTION
This Embedded NetRAID update only updates the firmware
on the CPU baseboard. When you reboot the NOS after this
update, you will get an error message caused by conflicts
between the NetRAID information stored elsewhere in the
system and the new information saved in the CPU baseboard
firmware. Use the HP NetRAID Express Tools utility to
reconfigure your system, based on the configuration details
you documented before starting the upgrade.
10.
Enter the Setup utility by pressing F2 at the screen prompt. Run "Clear
Config" to clear the SCSI Controller, Embedded RAID, and system
configuration.
NOTE
If you do not push F2 quickly enough, you may be immediately
routed to the HP NetRAID Express Tools utility to remedy the
problem noted in the above CAUTION. Perform the Embedded
RAID reconfiguration, then proceed to the Setup
reconfiguration.
11.
Reconfigure Embedded RAID and Setup according to the configuration
you saved earlier. You should not need to reinitialize the hard disks.
12.
Reboot the system and:
A.
Reconfigure Integrated Remote Assistant
B.
Clear the System Event Log
Update the Operating System
NOTE
If you are upgrading from a single-processor to multi-processor
machine, you may have to reinstall the operating system. Please
consult with your operating system vendor.
WARNING
Navigator will prompt the user, "Would you like to use HP’s
automated mode of NOS Installation?" The default is "Yes." If
you choose "Yes," whatever was on the C: drive will be lost.