HP Microportable Projector MP1800 MP1800 Microportable Projector - Page 55

WARNING, IMPORTANT, After replacing the lamp module, remember to reset - bulb

Page 55 highlights

5. Use the provided Phillips screwdriver to remove the screw ™ from the lamp cover. 6. Remove the cover š. 7. On the left side of the lamp module, push the electrical connector › up to disengage it from the projector base. 8. Remove the three screws œ from the lamp module. 9. Pull out the lamp module . ! WARNING: To reduce the risk of personal injury, do not drop the lamp module or touch the glass bulb. The glass may shatter and cause an injury if it is dropped. Reverse the previous steps to replace the lamp module. ✎ After replacing the lamp module, remember to reset the lamp hours in the on-screen menu. IMPORTANT: The lamp contains < 0.125 percent mercury by weight. If the projection lamp breaks, the mercury may be released into the atmosphere. Please follow applicable federal, state, and local regulations for disposal and/or recycling. Care and Maintenance 5-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

Care and Maintenance
5-5
5.
Use the provided Phillips screwdriver to remove the screw
from the lamp cover.
6. Remove the cover
.
7.
On the left side of the lamp module, push the electrical
connector
up to disengage it from the projector base.
8.
Remove the three screws
from the lamp module.
9.
Pull out the lamp module
.
!
WARNING:
To reduce the risk of personal injury,
do not drop the lamp module or touch the glass bulb.
The glass may shatter and cause an injury if it is
dropped.
Reverse the previous steps to replace the lamp module.
After replacing the lamp module, remember to reset
the lamp hours in the on-screen menu.
IMPORTANT:
The lamp contains < 0.125 percent mercury by
weight. If the projection lamp breaks, the mercury may be released
into the atmosphere. Please follow applicable federal, state, and