HP StorageWorks 4/64 Brocade Fabric OS Command Reference Manual (53-1000240-01
HP StorageWorks 4/64 - SAN Switch Manual
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 4/64 manual content summary:
- HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 1
Fabric OS Command Reference Manual Supporting Fabric OS v5.2.0 Publication Number: 53-1000240-01 Publication Date: 09/29/2006 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 2
http://www.brocade.com/support/oscd. Export of technical data contained in this document may require an export license from the United States government. Brocade Communications Systems, Incorporated Corporate Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San Jose, CA - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 3
-08 Rev. A Manual September 1999 May 2000 December 2000 July 2001 December 2001 March 2002 September 2002 April 2003 April 2003 May 2003 July 2003 August 2003 October 2003 Excluding edits and commands updated to support the SilkWorm 3250, 3850, and 24000 switches, added 3 commands - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 4
Number Summary of Changes Publication Date Fabric OS Command Reference 53-0000519-09 Manual Fabric OS Command Reference 53-0000519-10 Manual Fabric OS Command Reference 53-0000519-12 Manual Fabric OS Command Reference 53-1000240-01 Manual Chapter 3 "MUA-Based Roles," and move to support XML delivery - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 5
22 aliAdd 2-25 aliCreate 2-26 aliDelete 2-27 aliRemove 2-28 aliShow 2-29 aptPolicy 2-30 auditCfg 2-32 authUtil 2-33 backplaneTest 2-35 backport 2-37 bannerSet 2-39 bannerShow 2-40 bcastShow 2-41 bladeBeacon 2-42 Fabric OS Command Reference Manual v Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 6
48 burninStatus 2-49 camTest 2-50 centralMemoryTest 2-52 cfgActvShow 2-56 cfgAdd 2-57 cfgClear 2-58 cfgCreate 2-59 cfgDelete 2-60 cfgDisable 2-61 cfgEnable 2-62 cfgRemove 2-63 cfgSave 2-64 2-90 configUpload 2-93 vi Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 7
2-130 diagShow 2-131 diagShowTime 2-132 diagSkipTests 2-133 diagStatus 2-134 diagStopBurnin 2-135 distribute 2-136 dlsReset 2-137 dlsSet 2-138 dlsShow 2-139 dnsConfig 2-140 Fabric OS Command Reference Manual vii Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 8
fastboot 2-170 fazoneAdd 2-171 fazoneCreate 2-172 fazoneDelete 2-174 fazoneRemove 2-175 fazoneShow 2-176 fcipChipTest 2-177 fcipPathTest 2-179 fcLunQuery 2-181 fcPing 2-182 viii Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 9
2-213 fdmiShow 2-214 ficonClear 2-215 ficoncupset 2-216 ficoncupshow 2-217 ficonHelp 2-218 ficonShow 2-219 filterTest 2-225 firmwareCommit 2-227 firmwareDownload 2-228 firmwareDownloadStatus 2-232 Fabric OS Command Reference Manual ix Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 10
h 2-264 haDisable 2-265 haDump 2-266 haEnable 2-268 haFailover 2-269 haShow 2-270 haSyncStart 2-272 haSyncStop 2-273 help 2-274 historyLastShow 2-275 historyMode 2-276 x Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 11
2-317 itemList 2-319 killTelnet 2-321 licenseAdd 2-323 licenseHelp 2-324 licenseIdShow 2-325 licenseRemove 2-326 licenseShow 2-327 linkCost 2-328 login 2-330 logout 2-331 Fabric OS Command Reference Manual xi Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 12
nsAllShow 2-368 nscamShow 2-369 nsShow 2-371 nsZoneMember 2-375 passwd 2-378 passwdCfg 2-381 pathInfo 2-385 pdShow 2-389 perfAddEEMonitor 2-390 perfAddIPMonitor 2-392 xii Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 13
2-421 pkiCreate 2-423 pkiRemove 2-424 pkiShow 2-425 policy 2-426 portAlpaShow 2-429 portBufferShow 2-430 portCamShow 2-433 portCfg 2-436 portCfgDefault 2-442 portCfgEPort 2-443 Fabric OS Command Reference Manual xiii Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 14
portLogDisable 2-480 portLogDump 2-481 portLogDumpPort 2-483 portLogEnable 2-484 portLogEventShow 2-485 portLoginShow 2-488 portLogPdisc 2-489 portLogReset 2-490 portLogResize 2-491 portLogShow 2-492 xiv Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 15
2-538 powerOffListShow 2-540 psShow 2-541 quietMode 2-542 reboot 2-543 routeHelp 2-544 saveCore 2-545 secActiveSize 2-549 secAuthSecret 2-550 secCertUtil 2-552 secDefineSize 2-556 Fabric OS Command Reference Manual xv Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 16
secTempPasswdSet 2-595 secTransAbort 2-596 secVersionReset 2-597 sensorShow 2-598 setDbg 2-599 setEsdMode 2-600 setGbicMode 2-601 setMediaMode 2-602 setModem 2-603 setSfpMode 2-605 xvi Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 17
2-650 supportSave 2-652 supportShow 2-655 supportShowCfgDisable 2-661 supportShowCfgEnable 2-662 supportShowCfgShow 2-663 switchBeacon 2-664 switchCfgPersistentDisable 2-665 switchCfgPersistentEnable 2-666 Fabric OS Command Reference Manual xvii Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 18
topologyShow 2-698 traceDump 2-700 traceFtp 2-701 trackChangesHelp 2-703 trackChangesSet 2-704 trackChangesShow 2-705 trunkDebug 2-706 trunkShow 2-707 tsClockServer 2-709 tsTimeZone 2-711 xviii Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 19
3-3 ISL Trunking Commands 3-4 Advanced Performance Monitoring Commands 3-4 Secure Fabric OS Commands 3-6 Exclusive Primary FCS Commands Commands Exclusive to the Primary FCS 4-1 Fabric OS Command Reference Manual xix Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 20
Commands Commands Supported on the Standby CP 5-1 Chapter 6 supportShow Reference supportShow Control Commands 6-1 supportShow Command Groups 6-2 Proc Entry Information Displayed 6-4 Appendix A RBAC Command Availability Index xx Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 21
manual written to help system administrators and technicians operate, maintain, and troubleshoot SAN products. "About This Document" contains the following sections: • "How This Document Is Organized," next • "Supported a Brocade SAN and Brocade SilkWorm switches. 48000 directors. Role-Based Access - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 22
4900 switch • Brocade SilkWorm 7500 switch • Brocade SilkWorm 24000 director • Brocade SilkWorm 48000 director In those instances in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 23
- iscsiCfg - iscsiChipTest - iscsiHelp - iscsiPathTest - iscsiPortCfg - iscsiSessionCfg - iscsiTargetName - isnscCfg - lsanZoneShow - passwdCfg - policy - portCfg - portCfgEXPort - portCfgNPIVPort - portCfgVEXPort Fabric OS Command Reference Manual xxiii Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 24
- slotOff - slotOn - switchShutdown - switchStart - traceTrig - voltShow - Chapter 3, "MUA-Based Roles." The relevant content was moved to Chapter 1. For further information, please refer to the Release Notes. xxiv Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 25
portions of this guide are presented in potential damage to hardware, firmware, software, or data. Warning SAN-specific terms, visit the Storage Networking Industry Association online dictionary at http://www.snia.org/education/dictionary. Fabric OS Command Reference Manual xxv Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 26
and on the Brocade Web site, through Brocade Connect. Note Go to http://www.brocade.com and click Brocade Connect to register at no cost for a user ID and password. Fabric OS • Fabric OS Administrator's Guide • Fabric OS Command Reference Manual • Fabric OS MIB Reference Manual • Fabric OS Message - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 27
Replacement Procedure • SilkWorm 3900 Power Supply Replacement Procedure SilkWorm 3250/3850 • SilkWorm 3250/3850 Hardware Reference Manual (for v4.x software) • SilkWorm 3250/3850 QuickStart Guide (for v4.x software) Fabric OS Command Reference Manual Publication Number: 53-1000240-01 xxvii - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 28
200E Hardware Reference Manual (for v5.x software) For practical discussions about SAN design, implementation, and maintenance, you can obtain Building SANs with Brocade Fabric Switches through: http://www.amazon.com For additional Brocade documentation, visit the Brocade SAN Info Center and - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 29
leave the tunnel. Fabric OS supports eight FCIP interswitch links between two SilkWorm switches (SilkWorm 7500 or SilkWorm 48000 with a FR4-18i blade) or routes. All 16 links can be used as FCIP http://www.fibrechannel.org Fabric OS Command Reference Manual xxix Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 30
Information • Technical Support contract number, if applicable • Switch model • Switch operating system version • Error numbers and messages received • supportSave command output • Detailed description of the problem and specific questions • Description of any troubleshooting steps already performed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 31
. Forward your feedback to: [email protected] Provide the title and version number and as much detail as possible about your issue, including the topic heading and page number and your suggestions for improvement. Fabric OS Command Reference Manual xxxi Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 32
xxxii Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 33
SAN and Brocade SilkWorm switches and directors using the Fabric OS command line interface (CLI). The following information is discussed: • "Understanding Role-Based Access Control" on page 1-1 • "Using the Command Line Interface" on page 1-2 Refer to Fabric OS Administrator's Guide for information - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 34
in this manual. Access is controlled by a switch-level password for each access level. The commands available through the CLI are based on the user's login role and the license keys used to unlock certain features. Fabric OS CLI is the complete fabric management tool for Brocade SANs, providing - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 35
Fabric OS Commands Chapter 2 Fabric OS Command Reference Manual 2-1 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 36
. This rearranges the order that the specified RADIUS server is used. --localonly Enable authentication via the switch-local database only. This is used to select the switch-local database as the primary AAA service. 2-2 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 37
CHAP CHAP Primary AAA Service: Switch database Secondary AAA Service: None To change the configuration for server 192.168.233.48: switch:admin> aaaconfig --change 192.168.233.48 -p 3002 -s newsecret -t 1 See Also none Fabric OS Command Reference Manual 2-3 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 38
To set the default zone mode to "No Access": switch:admin> ad --select AD0 switch:admin> defzone --noaccess switch:admin> cfgsave All switches, switch ports and devices from the fabric that are not specified in any other Admin Domain 2-4 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 39
PI Uses existing zone D,PI member types. Benefits include: • Grants port control and zoning on the switch port and the devices attached to that port. • PI can be specified as a range; for member types. Benefits include: Fabric OS Command Reference Manual 2-5 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 40
switch list with a semicolon (;). Specify the switch in one of the following formats: • Switch WWN • Domain ID Note Any switch member specified using Domain ID format will be converted into a switch WWN based AD0 is always in an activated state. By default, after the Admin Domain is enabled, the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 41
current transaction buffer contents to the defined configuration and enforces the defined configuration on all switches in the fabric. ad --apply prompts for confirmation. --clear Deletes all ADs and Domain. The remove Fabric OS Command Reference Manual 2-7 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 42
number. The rename operation remains in the transaction buffer until you issue ad --apply or ad --save. --save Saves the outstanding Admin Domain transaction to the defined configuration in all the switches Domain aware switch or if the Domain aware switches and switch WWNs specified in AD's switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 43
Note Note: ad --show and ad --validate may return incorrect information about switch port members for non-AD aware switches running pre-v3.2 Fabric OS. This is because pre-v3.2 Fabric OS does not support Exchange Service Support (ESS), and therefore the Name Server cannot get the correct port range - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 44
Admin Domain name (this operation fails if AD_test's AD number is not 200): switch:admin> ad --rename AD_test AD200 To remove the device 100,5 and 1,3 from AD1: switch:admin> ad --remove "AD1", -d "100,5; 1,3; no, n): [no] y 2-10 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 45
; 1,13; 1,14; 1,15; 10:00:00:60:69:00:02:53; To display the AD1 configuration information in the transaction buffer: switch:admin> ad --show 1 -m 0 Current AD: 255 : AD255 Transaction buffer configuration no configuration Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-11 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 46
Device WWN members: Switch port members: Switch WWN members: 21:00:00:80:e5:12:8b:37; 21:00:00:80:e5:12:8b:55; 1,0; 1,1; 1,2; 1,3; 1,4; 1,5; 1,6; 1,7; 1,8; 1,9; 1,10; 1,11; 1,12; 1,13; 1,14; 1,15; 10:00:00:60:69:00:02:53; 2-12 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 47
Admin Domain transaction: switch:admin> ad --transshow Current transaction token is 26816 It is abortable switch:admin> ad --transshow There is no outstanding zoning transaction See Also cfgSave, cfgTransShow, defZone, logout Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 48
Gateway. Ports The number of ports in the Access Gateway. Enet IP Addr The IP address of the Access Gateway. Firmware The version of the Access Gateway firmware running on Access Gateway registered Access Gateways. 2-14 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 49
:00:00:00:c9:3f:7c:b9 To display the locally registered Access Gateways: switch:admin> agshow --local Name Ports Enet IP Addr Firmware Local/Remote WT_Stealth 16 10.202.90.231 v1.0.0 local See Also portCfgNPIVPort Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-15 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 50
is "End User Premise". sysContact The contact information for the system. The default value is "Field Support". Refer to the Fabric OS MIB Reference Manual for detailed sysDescr, sysLocation, and sysContact descriptions. authTraps When enabled, the authentication trap, authenticationFailure - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 51
comparing nonzero IP octets. For example, an ACL of 192.168.64.0 enables access by any hosts that start with the specified octets. default ***** Current SNMP Agent Configuration Customizable MIB-II system variables: sysDescr = Fibre Channel Switch. Manual Publication Number: 53-1000240-01 2-17 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 52
: Entry 0: Access host subnet area 192.168.64.0 (rw)] Entry 1: No access host configured default Current SNMP Agent Configuration Customizable MIB-II system variables: sysDescr = Fibre Channel Switch. sysLocation = End User Premise sysContact = Field Support Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 53
in the switch. All values successfully configured by this command take effect immediately. These values are persistent across power cycles and system. The default value is "Field Support". Refer to the Fabric OS MIB Reference Manual for detailed Manual Publication Number: 53-1000240-01 2-19 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 54
For example, an ACL of 192.168.64.0 enables access by any hosts that start with when all six entries contain 0.0.0.0. The default values of all six entries are 0.0.0.0. Note switch only and will propagate across the fabric. Operands none 2-20 Fabric OS Command Reference Manual Publication Number: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 55
192.168.64.0 Read/ mib, "Switch Management Information & Switch Enterprise Specific Trap", RFC1157, "A Simple Network Management Protocol (SNMPv1)", RFC1213, "Management information Base for Network Management of TCP/IP-based Internets: MIBII" Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 56
The system (switch) description. The default value is "Fibre Channel Switch". sysLocation The location of the system. The default value is "End User Premise". sysContact The contact information for the system. The default value is "Field Support". Refer to the Fabric OS MIB Reference Manual for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 57
For example, an ACL of 192.168.64.0 enables access by any hosts that start with when all six entries contain 0.0.0.0. The default values of all six entries are 0.0.0.0. Note switch only and will propagate changes across the fabric. Operands none Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 58
192.168.64.0 ( mib, "Switch Management Information & Switch Enterprise Specific Trap", RFC1157, "A Simple Network Management Protocol (SNMPv1)", RFC1213, "Management information Base for Network Management of TCP/IP-based Internets: MIBII" 2-24 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 59
, array2, and loop1: switch:admin> aliadd "array1", "1,2" switch:admin> aliadd "array2", "21:00:00:20:37:0c:72:51" switch:admin> aliadd "loop1", "4,5[0x02]; 6,7[0xEF]" See Also aliCreate, aliDelete, aliRemove, aliShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-25 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 60
zone alias: switch:admin> alicreate "array1", "2,32; 2,33; 2,34" switch:admin> alicreate "array2", "21:00:00:20:37:0c:66:23" switch:admin> alicreate "loop1", "4,5[0x02]; 6,7[0xEF]; 5,4" See Also aliAdd, aliDelete, aliRemove, aliShow 2-26 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 61
a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. zone alias array2: switch:admin> alidelete "array2" See Also aliAdd, aliCreate, aliRemove, aliShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 62
a World Wide Name from "array1": switch:admin> aliremove "array1", "3,5" switch:admin> aliremove "array1", "21:00:00:20:37:0c:76:8c" switch:admin> aliremove "array1", "0xEF" See Also aliAdd, aliCreate, aliDelete, aliShow 2-28 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 63
be issued only from the primary FCS switch. Operands Examples This command has the following the contents of the nonvolatile memory. The default value is 0. If no parameters are this display. To display all zone aliases beginning with "arr": switch:admin> alishow "arr*" alias: array1 21:00:00:20: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 64
discussion is beyond the scope of this manual. The default parameters are optimal for most SAN applications; typical customers do not need to use this command. When used with no arguments, this command displays a list of APT policies supported on this switch, as well as the current policy. This - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 65
1 Policy updated successfully. switch:admin> switchenable switch:admin> aptpolicy Current Policy: 1 3: Default Policy 1: Port Based Routing Policy 3: Exchange Based Routing Policy See Also dlsReset, dlsSet, dlsShow, switchDisable Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 66
. Based on FIRMWARE switch:admin> auditcfg --class 2,3 Audit filter is configured. switch:admin> auditcfg --disable Audit filter is disabled. switch:admin> auditcfg --show Audit filter is disabled. 2-SECURITY 3-CONFIGURATION See Also none 2-32 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 67
authentication, and "all" to set both FCAP and DH-CHAP (default). When authentication is set to "all", implicit order is FCAP followed switch: switch:admin> authutil --show AUTH TYPE HASH TYPE GROUP TYPE fcap,dhchap sha1,md5 0,1,2,3,4 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 68
--set -g 3 DH Group was set to 3. To set all DH groups to be specified in auth negotiate in order of 0, 1, 2, 3, and 4: switch:admin> authutil --set -g "*" DH Group is set to 0,1,2,3,4 See Also portShow, secAuthSecret 2-34 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 69
the backplane connection for a multiple-blade configured system. Synopsis backplanetest [--slot number][-passcnt count][-payload value][-pat in detail. The default value is to disable the mode. To test backplane connections on a SilkWorm director: switch:admin> backplanetest -ports 1/16, 18, 20 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 70
the following error messages: • DATA • TIMEOUT • XMIT Refer to the Fabric OS Message Reference for more information. See Also itemList 2-36 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 71
allocation. This test applies to single blade as well as multiblade systems. The -extonly is set to 1. This command is supported only on SilkWorm 3250, 3850, 3900,4100 default value is all user ports. Refer to itemList for more information. Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 72
Selects the loopback point for the test. By default, backport uses internal loopback. Mode Description 1 Port to each link. To test for backend ASIC pair links: switch:admin> backport -ports 1/1-1/3 -nframes 840 One moment please ... Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 73
banner" switch:admin> bannerSet Please input context of security banner (press "." RETURN at the beginning of a newline to finish input): Do not log into this switch if you are not an authorized administrator. . See Also bannerShow Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 74
restrictions that may be in place. Operands Examples none To display the banner for a switch: switch:admin> bannershow Banner: Do not log into this switch if you are not an authorized administrator. See Also bannerSet 2-40 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 75
, from a switch with 128 ports, the member ports consist of ports 7, 13, 42, 84, 85, and 86. The final Member Ports bit set represents the embedded port (frames sent to be handled by firmware) and is typically set. portRouteShow Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 76
slot is displayed. To enable beaconing on slot 2, display the beaconing mode, then disable it: switch:admin> bladebeacon 2 1 switch:admin> bladebeacon 2 value = 1 switch:admin> bladebeacon 2 0 See Also switchShow 2-42 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 77
this blade, the remaining switches reconfigure, and this switch will configure based on the other blade ports. The blade must be disabled before making configuration changes or before running many of the diagnostic tests. The blade does not need to be disabled before rebooting or powering off - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 78
do not initialize. Note A blade cannot be disabled or enabled when the switch is disabled or when the blade itself is faulted, powered off, or running diagnostics. : slotnumber Specify the slot number to be enabled. 2-44 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 79
VACANT 4 SW BLADE 2 ENABLED 5 CP BLADE 1 ENABLED 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED 8 UNKNOWN VACANT 9 UNKNOWN VACANT 10 UNKNOWN VACANT See Also bladeDisable, portDisable, portEnable, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 80
The operand is a follows: slotnumber A nonzero value that specifies the slot number from which to clear burn-in errors. To clear burn-in errors from slot 2. switch:admin> burninerrclear 2 See Also burninErrShow 2-46 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 81
is as follows: slotnumber A nonzero value that specifies the slot number from which to display burn-in errors. Examples To display burn-in errors from slot 2: switch:admin> burninerrshow 2 See Also burninErrClear Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-47 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 82
testing in place of the power-on self-test (POST) phase II each time a switch blade is powered on. The mode becomes switch:admin> burninlevel -show Burnin level is 0. See Also burninErrShow, diagDisablePost, diagEnablePost, diagSetBurnin 2-48 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 83
each blade in the system. The output contains the slot, state, current run number, current Examples To display the burn-in status for all slots: switch:admin> burninstatus Slot State Status Run 1 ABORT PASS 3 the burn-in status for slot 3: switch:admin> burninstatus --slot 3 Slot State - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 84
executed on an enabled switch. You must first disable the switch using the switchDisable command. This command is supported only on the SilkWorm the number of times to perform this test. The default value is 1. -txport itemlist Specify a list of blade ports to test. By default, all the blade ports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 85
Refer to the Fabric OS Message Reference for more information. See Also centralMemoryTest, cmemRetentionTest, cmiTest, crossPortTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-51 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 86
switch. You must first disable the switch using the switchDisable command. This command is supported replaced, the BIST is executed again. The firmware sets up the hardware for the BISR/ bit is toggled during the test. The default pattern used (by POST also) is Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 87
pattern. 4. Repeat this procedure for each ASIC pair in the blade under test. The pattern used is generated similarly as in switch: a. Write a 64-byte pattern in the central memory. b. Read X from all ASIC Y in the switch. c. For ASIC X, ensure: Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 88
before the test is run. By default, all the blade ports in the specified slot (--slot) are tested. Refer to itemList for more information. -seed value Specify the data pattern seed to be used. The default seed value is 0. 2-54 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 89
for readability. centralMemoryTest 2 Examples To test the ASIC central memory: switch:admin> centralmemorytest -ports 1/0-1/15 Running centralmemorytest Test Complete: centralmemorytest Pass spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-55 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 90
information: switch:admin> cfgactvshow Effective configuration: cfg: c4 zone: z3 33:07:06:05:04:03:02:01 zone: z4 44:01:23:45:67:89:a0:bc 40:01:23:45:67:89:a0:bc See Also cfgClear, cfgDelete, cfgRemove, cfgSave, cfgShow 2-56 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 91
Assist) zone names To add two new zones to the configuration "Test_cfg": switch:admin> cfgadd "Test_cfg", "redzone; bluezone" See Also cfgClear, cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-57 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 92
the default zoning objects. Note This command requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch. n See Also cfgDisable, cfgEnable, cfgSave 2-58 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 93
) zone names To create a configuration containing three zones: switch:admin> cfgcreate "USA_cfg", "Red_zone; Blue_zone; Green_zone" See Also cfgAdd, cfgClear, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-59 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 94
to be deleted, in quotation marks. This operand is required. To delete a zone configuration: switch:admin> cfgdelete "USA_cfg" See Also cfgAdd, cfgClear, cfgCreate, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow 2-60 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 95
switches to indicate the aborting of the transaction. If the default zone access mode is "No Access", then this command becomes cfgEnable "d_efault_Cfg". See defZone. Note This command requires a Brocade , cfgEnable, cfgSave Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-61 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 96
command requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch. Operands Examples This flash ... See Also cfgClear, cfgDisable, cfgSave, cfgShow 2-62 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 97
Assist) zone names To remove a zone from a configuration: switch:admin> cfgremove "Test_cfg", "redzone" See Also cfgAdd, cfgClear, cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgSave, cfgShow, cfgTransAbort, cfgTransShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-63 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 98
to nonvolatile memory in all switches in the fabric. The saved configuration is automatically reloaded by the switch on power on and, if a cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgShow, cfgTransAbort, cfgTransShow 2-64 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 99
sees in the fabric are based on this configuration. The effective checking has been completed successfully. When default zoning is enabled with "No Brocade Advanced Zoning license. When security is enabled, this command can be issued on any FCS switch Manual Publication Number: 53-1000240-01 2-65 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 100
2 Note: Enter commands in lowercase only; mixed case is for readability. cfgShow must be enclosed in brackets: for example, [0-9] or [a-f]. 2-66 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 101
default value is 0. This operand is optional. To display all zone configurations that start with "Test": switch display all zone configuration information: switch:admin> cfgshow Defined configuration: :0c:71:df To display only configuration names: switch:admin> cfgshow "*" cfg: USA1 Blue_zone cfg: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 102
requires a Brocade Advanced Zoning license. When security is enabled, this command can be issued only from the primary FCS switch. Operands : switch:admin> cfgsize Zone DB max size - 1045274 bytes committed - 244 transaction - 0 2-68 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 103
switch 16 bytes transaction - 0 bytes Zone CFG Info for AD Number: 2 (AD Name: ad2): committed - 0 bytes transaction - 0 bytes Zone CFG Info for AD Number: 3 (AD Name: ad3): committed - 0 bytes transaction - 0 bytes See Also ad, cfgShow, zoneHelp Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 104
to obtain the token ID of a transaction. To abort the current transaction: switch:admin> cfgtransabort See Also cfgAdd, cfgClear, cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow, cfgTransShow 2-70 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 105
configurations... switch:admin> cfgtransshow Current transaction token is 271010736 It is abortable (yes, y, no, n): [no] y See Also cfgAdd, cfgClear, cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow, cfgTransAbort Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 106
1 and 2 and SilkWorm 48000 directors support options 1 and 5: 1 One 128-port switch (blade ID 4, 17 on slots 1 - 4 and 7 - 10; blade ID 5, 16 on slots 5 - 6) 2 Two 64-port switches (blade ID 4 on slots 1 - 4 and 7 - 10; blade ID 5 on slots 5 - 6) 5 One 384-port switch (Blade ID 17, 18, 24, 31 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 107
the userConfig command are deleted and user accounts are reset to the factory default user accounts and passwords. Note The execution of this command is subject to Admin Domain restrictions that a list of all valid options. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-73 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 108
on a SilkWorm 48000 director and to change the option: switch:admin> chassisconfig Current Option: 5 All Supported Options (With Blade ID 5 on slots 5-6 Option 1: One 128-port switch (Blade ID 4, 17 on slots 1-4, 7-10, Blade ID 5, 16 on slots 5-6) Option 5: One 384-port switches (Blade ID's 17, 18 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 109
, the current chassis name displays. Examples To change the chassis name to "dilbert": switch:admin> chassisname dilbert Please wait while committing configuration... switch:admin> chassisname dilbert See Also switchName Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-75 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 110
, FAN, POWER SUPPLY, SW BLADE (switch), CP BLADE (control processor), WWN (World Wide Name), or UNKNOWN. Object number: Slot nn (for blades), Unit nn (for everything else). If the FRU is part of an that may be in place. 2-76 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 111
case is for readability. chassisShow 2 Operands Examples none To display all FRUs for a switch: switch:user> chassisshow Chassis Backplane Revision: 1C SW BLADE Slot: 3 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: ID - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 112
2 Note: Enter commands in lowercase only; mixed case is for readability. chassisShow See Also slotShow 2-78 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 113
blade to display. The default is set to 0 and designed to operate on fixed-port-count products. filter Specifies a filter string. To display the port registers of a chip: switch:admin> chipregshow 1/1 ffffffff See Also minisPropShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 114
is run. By default, all the blade ports in the specified slot (--slot) are tested. Refer to the itemList help pages for further details. -seed value Specify the data pattern seed to be used. The default seed value is 0. 2-80 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 115
the data-retention test on the central memory SRAMS: switch:admin> cmemretentiontest --slot 7 Running cmemretentiontest Test Complete: 0 hr, 1 min & 33 sec (0:1:33:16). passed. Diagnostics The following are possible error messages Command Reference Manual Publication Number: 53-1000240-01 2-81 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 116
is supported only number to test. The default is number of test passes to run. By default, the test runs one time. -txports itemlist Specifies a list of ports to transmit data. By default receive data. By default, all the ports test between two ASIC pairs: switch:admin> cmitest -txports 7/0-7/7 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 117
-INTNIL Refer to the Fabric OS Message Reference for more information. See Also camTest, centralMemoryTest, cmemRetentionTest, crossPortTest, itemList, portLoopbackTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-83 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 118
Brocade Advanced Zoning configuration (includes aliases, zones and configurations) • Security parameters and policies • User account passwords (includes all user config and all built-in accounts) • Switch PID Operands none 2-84 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 119
readability. configDefault 2 Examples To restore the system configuration to default values: switch:admin> configdefault Committing Configuration ...done. See Also agtCfgDefault, configure, switchDisable, switchEnable Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-85 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 120
password if necessary. The SSH service is also available on Unix and Windows hosts. For Admin Domain users, please refer to the Fabric OS Administrator's Guide to disable the switch before proceeding). • The host name is not known to the switch. • The host Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 121
Note [License] is only accepted if the boot.mac parameter matches the licenseid (WWN) of the switch performing the download; otherwise, it is ignored. Note The download process is additive. The lines read may be in place. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-87 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 122
. Do you want to continue [y/n]: y Password: ******** Activating configDownload without disabling switch: configDownload complete: All config parameters except AD Headers, SFOS and Security parameters are downloaded to AD0 2-88 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 123
to take effect. Do you want to continue [y/n]: y configDownload completed successfully. All parameters are downloaded. switch:admin> switchenable switch:admin> See Also configDefault, configShow, configUpload, configure Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-89 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 124
of wildcards and other common regular expression operators is not supported. Some configuration settings will not display selectively in this manner configuration settings for "passwdcfg": switch:admin> configshow "passwdcfg" passwdcfg OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 125
.ididmode:0 fabric.ops.BBCredit:16 fabric.ops.E_D_TOV:2000 fabric.ops.R_A_TOV:10000 fabric.ops.dataFieldSize:2112 fabric.ops.max_hops:7 fabric.ops.mode.fcpProbeDisable:0 fabric.ops.mode.isolate:0 (continued on next page) Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-91 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 126
:0.0.0.0 fc4.fcIp.mask:0.0.0.0 fc4.fcp.productId:FC Switch fc4.fcp.vendorId:BROCADE fcAL.alwaysSendRSCN:0 fcAL.fanFrameDisable:0 fcAL.openSendCLS:4 fcAL diagDisablePost, diagEnablePost, ipAddrShow, licenseShow, syslogdIpShow 2-92 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 127
will prompt for the password if necessary. The SSH service is also available on Unix and Windows hosts. This command can be invoked without any operands, creating an interactive session. The upload might fail for the following reasons: • The host name is not known to the switch. • The host IP - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 128
general switch configuration the Fabric OS Administrator's Guide for details regarding configUpload and default. "host" Specifies a host name or IP address in quotation marks: for example, "citadel" or "192.168.1.48 Windows hosts. "passwd" Specifies the password for the FTP login. Note No spaces - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 129
[config.txt]: config.txt Password: ******** configUpload complete: All config parameters except AD Headers,SFOS and Security parameters are uploaded from AD0 See Also configDefault, configDownload, configShow, configure Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-95 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 130
Services Settings" • "Portlog Events Enable/Disable Settings" • "Application Attributes" Note If executed on an enabled switch input, accepts the default value (if applicable) switches to allow formation of the fabric. 2-96 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 131
Long Distance Fabric boolean 0 BB Credit number 16 Insistent Domain ID Mode boolean 0 Range varies E_D_TOV * 2 to 120000 1000 to R_A_TOV / 2 0 to R_A_TOV / 4 7 to 19 256 to 2112 0 or 1 0 or 1 0 or 1 1 to 2 0 or 1 0 or 1 1 to 27 0 or 1 Descriptions of the switch fabric setting fields are as - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 132
Edge PID Format (16 based, 256 port format), used in mixed fabrics with legacy and new switches to avoid the need to reboot host systems when static PID binded is used. Per-frame Route Priority In addition to the eight virtual channels used in frame routing priority, support is also available - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 133
N_Port ID virtualization (NPIV) ports in the switch. Table 2-5 F_Port Login Parameters Field Type Default Range Maximum logins per switch Number 15*ports 1 to 126*ports Maximum logins per port Number 126 1 to 255 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-99 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 134
Modes Field End-device RSCN Transmission Mode Domain RSCN to End-device for switch IP address or name change Type number number Default 1 0 Range 0 to 2 0 to 1 End-device RSCN Transmission Mode set to 0, frames are not sent. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 135
Services Settings The System Services Settings are shown in the table. Table 2-8 Configure Command System Services Parameters Field Default The retrieval of this information is supported by a number of operating systems that support RPC. On most UNIX-based systems (HP-UX, Irix, Linux, Solaris, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 136
Attributes Application File Type Default Range ssl Certificate File string not set varies CA Certificate File string not set varies Length of crypto key number 128 40, 56, 128 correctly. Operands none 2-102 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 137
Enable CLOSE on OPEN received?: (0..1) [0] Always send RSCN?: (0..1) [0] Do Not Allow AL_PA 0x00?: (0..1) [0] System services(yes, y, no, n): [no] yes rstatd(on, off): [off] rusersd(on, off): [off] telnetd (on, off): [on] Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-103 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 138
off): [on] ctin(a CT based request is received ) (on, off): [on] ctout(a CT based response is transmitted ) (on, msg(fss message log ) switch(switch driver log ) ficonq(ficon queue and ELS measurements ) routing(switch/blade drivers routing logs ) ( Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 139
switch receiver, thus exercising all the switch components, from the main board, running. Note The command is supported only on SilkWorm 200E,3250, number of frames transmitted is not equal to the number of frames received. 9. Repeat steps 3 through 8 for all ports present until the number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 140
be used to determine which components of the switch are faulty. It is also possible to default, crossPortTest uses mode 1 port loopback. Valid values are: 0 Cable loopback 1 Port loopback (loopback plugs) 2 External (SERDES) loopback 2-106 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 141
Condor ASIC-based products, part of the POST cleanup normally performed. This might be helpful during debug. This parameter should normally be left at the default value of 0. Specify a list of user ports to test. By default, all the user ports in the current switch Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 142
sample data streams you can use with diagnostics: switch:admin> datatypeshow Pattern BYTE_FILL WORD_FILL QUAD_FILL BYTE_NOT WORD_NOT PRED_RAND type 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 example 00 00 00 00 00 00 00 00 00 00 00 00 Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 143
for more information on time zone support. If the switch is operating in FICON Management Server mode (fmsmode), setting the date is subject to the director clock alert mode (DCAM). If DCAM . This operand is optional. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-109 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 144
and then modify it: switch:admin> date Fri Jan 29 17:01:48 UTC 2000 switch:admin> date "0227123003" Thu Feb 27 12:30:00 UTC 2003 See Also errShow, ficoncupset, ficoncupshow, portLogShow, tsClockServer, tsTimeZone, upTime 2-110 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 145
. Module names are case sensitive. This operand is optional. Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-111 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 146
from a remote switch that does not support default zoning, zoning rejects the cfgDisable command in the second phase of RCS because the remote switch does not convert the cfgDisable command to a cfgEnable d_efault_Cfg command. 2-112 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 147
configuration: no configuration in effect switch:admin> defzone --noaccess switch:admin> cfgsave switch:admin> defzone --show Default Zone Access Mode committed - All Access transaction - No Transaction See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-113 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 148
a default zone configuration: switch:admin> cfgactvshow Effective configuration: no configuration in effect switch:admin> defzonecreate switch:admin> cfgactvshow Default Zone Access Mode committed - All Access transaction - No Transaction 2-114 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 149
Note: Enter commands in lowercase only; mixed case is for readability. defZoneCreate 2 See Also defZoneDelete Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-115 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 150
. Operands Examples None To delete a default zone configuration: switch:admin> cfgactvshow Effective configuration: no configuration in effect switch:admin> defzonedelete switch:admin> cfgactvshow See Also defZoneCreate 2-116 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 151
blades clear. If no operand is specified, the default is to clear all bad port flags. To clear the diag software flag: switch:admin> diagclearerror 8 ERROR: DIAG CLEARERR Diagnostics Errors Cleared, port: 8/31 Err# 0120041 081F See Also none Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 152
FR4-18i blade in a SilkWorm chassis; however, the command is not supported by the switch ASIC property minisregshow display contents of mini-switch registers. ptbufshow dump port buffer contents (output truncated) See Also diagHelp 2-118 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 153
required for this command to take effect. Operands none Examples To disable the POST during future power ons: switch:admin> diagdisablepost Config update Succeeded Diagnostic POST is now disabled. See Also diagEnablePost Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-119 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 154
Domain restrictions that may be in place. Operands Examples none To enable the POST during future power ons: switch:admin> diagenablepost Config update Succeeded Diagnostic POST is now enabled. See Also diagDisablePost 2-120 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 155
a mixed-blade environment. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands The operand is as follows: value Specify the value for the relevant diagnostic environment variable. Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 156
parameters: switch:admin> diagshowusr Name Environment USR_DILATION DIAG_USR_DLY_DILATION USR_MEMDLY DIAG_USR_MEMDLY USR_SEED DIAG_USR_SEED USR_SPECIAL DIAG_USR_SPECIAL (output truncated) See Also none Value 1 10 0x0 0x0 2-122 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 157
, the current value is displayed. Examples To change the fail limit from 1 to 5: switch:admin> diagfaillimit -show Fail Limit is 1. switch:admin> diagfaillimit 5 Fail Limit is now 5. Config update Succeeded See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-123 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 158
default operands when running diagnostics commands. Nondefault settings require detailed knowledge of the underlying hardware and are intended for support personnel only. Contact support information: switch:admin> diaghelp ) display blade properties display Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 159
can issue this command on the FR4-18i blade in a SilkWorm chassis; however, the command is not supported by the SilkWorm platform and does not the loop ID: switch:admin> diagloopid -show FL mode Loop ID is 125. See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 160
blade in a SilkWorm chassis; however, the command is not supported blade environment. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To display the diagnostic mode: switch Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 161
a reboot to take effect. POST mode modifies the behavior of the diagnostics daemon program to inhibit testing of switch blades when the system is first powered on or a new blade is added. Note To enable or disable diagnostic POST, the recommended method is to use diagEnablePost and diagDisablePost - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 162
effect. Retry mode modifies the behavior of the diagnostic test methods, power-on self-test (POST), and burnin scripts. The exact behavior depends switch:admin> diagretry -show Diagnostic Retry Mode is currently enabled. See Also none 2-128 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 163
from the burninErrShow command on a per-blade basis. When power cycles occur, the burn-in activity is restarted at the slot slotnumber Specify which slot number to update. If this option is not specified at all, then all slots on the switch are set up for Manual Publication Number: 53-1000240-01 2-129 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 164
full parameters, variables can be updated noninteractively. In interactive mode, the current value, default manually in this case. To update diagnostic command parameters: switch:admin> diagsetcycle switchburnin.sh -show CURRENT - KEYWORD : DEFAULT Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 165
ports specified in -uports displays. The default value is 0. Examples To display diagnostic status on a switch blade: switch:admin> diagshow Diagnostics Status: Fri Feb 08 ...... (output truncated) See Also itemList Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-131 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 166
-18i blade in a SilkWorm chassis; however, the command is not supported by switch:admin> diagshowtime Show Time mode is 0 (Disabled). switch:admin> diagshowtime 1 Config update Succeeded Show Time mode is now 1 (Enabled). See Also none 2-132 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 167
given, the current skip test flags displays. If no operand is specified, the current value is displayed. Examples To display the current skip test flags: switch:admin> diagskiptests -show Skip tests is 1. See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-133 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 168
command on the FR4-18i blade in a SilkWorm chassis; however, the command is not supported by the SilkWorm platform and omitted, all blades in the system are assumed. To display currently running diagnostic tests: switch:admin> diagstatus OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 169
, 1, " 1 Starting switchess ... Err# 0140042 0100:101:000:001:26:39: 0x47ff (fabos): Feb 07 21:45:36 Switch: 0, Error DIAG-MANUAL1, 1, " 1 switchess: ABORT ... Err# 0140042 0100:101:000:002:26:41:1N See Also diagSetBurnin Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-135 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 170
distribute the Switch Connection Control policy and Password database to all domains in the fabric that support the distribute feature: switch:admin> distribute -p "SCC;PWD" -d "*" Wildcard domains are: 1 3 5 See Also fddCfg 2-136 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 171
Refer to dlsSet for a full description of load sharing. correctly. DLS is not supported in certain routing policies. switch:admin> dlsreset Committing configuration...done. switch:admin> dlsshow DLS is not set See Also aptPolicy, dlsSet, dlsShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 172
DLS when a fabric change occurs. Routing is generally based on the incoming port and the destination domain. This The DLS option is on by default. Note DLS is not supported in certain routing policies. Refer to the dynamic load sharing option: switch:admin> dlsset switch:admin> dlsshow DLS is set - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 173
to dlsSet for a description of load sharing. Note DLS is not supported in certain routing policies. Refer to aptPolicy for more information on routing option setting: switch:admin> dlsshow DLS is set See Also dlsSet, dlsReset Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 174
option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration 3 Remove DNS configuration 4 Quit Select an item: (1..4) [4] 4 See Also configDownload, configUpload, firmwareDownload, ipAddrSet, ipAddrShow 2-140 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 175
). connid Displays the serial number of the switch used by the enclosure manager (not to be confused with the Factory Serial Number). conntype Displays the connector type used by the enclosure manager for this model of switch. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 176
enclosure manager. connfuse Displays whether or not the switch has a fuse. To display the identifier of the enclosure interface to which the switch is attached: switch:admin> enclosureShow slotid Bay 4 See Also chassisShow 2-142 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 177
this command to clear all internal and external error log messages for all switch instances on this CP. Note The execution of this command is subject the error log messages: switch:admin> errclear See Also errDump, errShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-143 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 178
operand is optional. To display the start and end delimiter: switch:admin> errdelimiterset delimiter start string: delimiter end string from device 10:02:32:A3:78:23:23:End See Also errDump, errFilterSet, errShow 2-144 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 179
logs from Fabric OS versions prior to v4.2. Examples To display the error log, without pagination: switch:user> errdump Version: 4.4.0 2004/07/14-22:24:08, [HAMK-1003], 1,, INFO, errDelimiterSet, errFilterSet, errShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-145 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 180
A filter is set based on the severity level switch:admin> errfilterset console: filter severity = WARNING To set the filter severity level for the console: switch:admin> errfilterset -d "console" -v "WARNING" See Also errDump, errShow 2-146 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 181
may be in place. Operands Examples none To display a list of all defined error log modules: switch:user> errmoduleshow KT UT TRCE KTRC LOG CDR BLPU PISP PIXE EGR BL PIC PS RTE AS AUTH truncated) See Also errDump, errShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-147 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 182
all switch instances number Sequence number for the message Security audit flag Security audit logged. AUDIT displays in the field. Severity Severity of the message. Valid values include INFO, WARNING, ERROR, and CRITICAL. Switch name Switch from all switch instances are displayed - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 183
mixed case is for readability. errShow 2 Examples To display the error log, with pagination: switch:user> errshow Version: 4.4.0 2004/07/14-22:24:08, [HAMK-1003], 1,, INFO, See Also errDelimiterSet, errDump, errFilterSet Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-149 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 184
exit command is an accepted synonym for logout, as is typing Ctrl-D at the beginning of a line. Operands none Examples To exit from a shell session: switch:admin> exit Connection to host lost. See Also logout 2-150 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 185
the fabric, as well as a list of pending commands. The following information displays: Port The port number. State The state of the port: P0 Port Offline P1 Port Online P2 ELP ACC Received P3 PTIO ioctl 0x00000040 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-151 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 186
Port is the EMT Initiator 0x00800000 Security violation 0x01000000 Security incompatibility 0x02000000 Rcv a DIA ACC 0x040000000 Port is security authenticating 0x080000000 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 187
portnumber Specifies the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. To display fabric port information: switch:admin> fabportshow 4/14 pending See Also portShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-153 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 188
Parameters FWN Firmware Notification ??? switch:user> fabretryshow SW_ILS E_Port ELP EFP HA_EFP DIA RDI BF FWD EMT ETP RAID GAID ELP_TMR GRE ECP 16 0 0 0 17 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 See Also fabStatsShow 2-154 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 189
log. By default, the fabric log is enabled. -e | --enable Enables fabric log. -r size | --resize size Changes the maximum number of log entries. The given size has to be at least 2 and a power of 2; otherwise, the command fails. Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 190
fabriclog -r 64 Warning: This command will clear the logs. Are your sure you want to do the resize [y/n]? y switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn,Pn Port Xid See Also fabPortShow, fabStatsShow 2-156 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 191
set principal switch selection mode for the switch. The implementation of the fabricPrincipal command is based solely on mechanisms switch:admin> fabricprincipal -f 1 Principal Selection Mode enabled (Forcing fabric rebuild) See Also fabricShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 192
192.168.64.180 192.168.65.180 >"sw180" 66: fffc42 10:00:00:60:69:00:05:91 192.168.64.60 192.168.65.60 "sw60" 67: fffc43 10:00:00:60:69:10:60:1f 192.168.64.187 0.0.0.0 "sw187" The Fabric has 4 switches 2-158 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 193
FC Router IP Addr Name 1: fffc01 fcr_sprint_01 10.33.59.224 160: fffca0 fcr_fd_160 0.0.0.0 10.33.59.25 fcr_meteor2 190: fffcbe fcr_mojo_6 10.33.59.32 The Fabric has 3 switches See Also switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-159 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 194
the fabric state information: switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2, ELP ACC Receive F2,P2 F2,P2 21 0x277 switch:admin> fabstateclear switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 195
> fabstateresize 64 Warning: This command will clear the logs. Are your sure you want to do the resize [y/n]? y switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid See Also fabricLog, fabStateClear, fabStateShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 196
Examples none To display the fabric state information: switch:admin> fabstateshow Time Stamp Input and *Action S, P Sn,Pn Port Xid 11955:655 SCN Switch Online F2,NA F2,NA NA NA 11955:657 fabStateResize, fabricLog 2-162 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 197
displays as follows: • Number of times a switch domain ID has been forcibly changed • Number of E_Port offline transitions • Number of fabric reconfigurations • Number of fabric segmentations due be in place. Operands none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-163 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 198
readability. fabStatsShow Examples To display the fabric statistics: switch:admin> fabstatsshow Description Count Domain ID forcibly changed: : 0 Duplicate WWN: 0 Eport Isolated: 0 See Also fabRetryShow 2-164 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 199
's to recover reachable domains: 1 3 4 3 domains reachable Ports used for EFP/BF/DIA flood: (output truncated) D0,NA D0,NA NA NA Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-165 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 200
2 Note: Enter commands in lowercase only; mixed case is for readability. fabSwitchShow See Also supportShow 2-166 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 201
to Admin Domain restrictions that may be in place. Operands Examples This command has the following operand: unit Specifies the fan unit number to disable. To disable a fan unit: switch:admin> fandisable 1 Fan unit 1 has been disabled See Also fanEnable, fanShow Fabric OS Command Reference - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 202
Use this command to set a previously disabled fan unit back to the default RPM speed. Note This command is not available on nonbladed systems except has the following operand: unit Specify the fan unit number to enable. To enable a fan unit: switch:admin> fanenable 1 Fan unit 1 has been enabled - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 203
To display information on the fans in the system: switch:admin> fanshow Fan #1 is OK, speed is 2721 RPM Fan #2 is OK, speed is 2657 RPM Fan #3 is OK, speed is 2700 RPM See Also chassisShow, fanDisable, fanEnable, psShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-169 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 204
for readability. fastboot fastboot Reboots the Control Processor (CP), bypassing Power-On Self-Tests (POST). Synopsis fastboot Description Use this command : switch:admin> fastboot See Also diagDisablePost, diagEnablePost, reboot 2-170 Fabric OS Command Reference Manual Publication Number: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 205
to "Blue_fazone": switch:admin> fazoneadd "Blue_fazone", "H{5,6}" To add another target member to "Blue_fazone": switch:admin> fazoneadd "Blue_fazone", "10:49:00:00:00:20:3f:2e" See Also fazoneCreate, fazoneDelete, fazoneRemove, fazoneShow Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 206
be followed by any number of letters, digits by physical fabric port number, then all devices specified as eight hex numbers separated by colons, for more physical fabric port numbers, WWNs, or a 8a" would contain devices connected to switch 2, ports 12 and 14, and preserved across switch reboots, it - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 207
"Red_fazone", "H{1,0}; loop1" switch:admin> fazoneCreate "Blue_fazone", "H{1,1}; array1; 1,2; array2" switch:admin> fazoneCreate "Green_fazone", "1,0; loop1; H{1,2}; array2" See Also fazoneAdd, fazoneDelete, fazoneRemove, fazoneShow Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 208
the cfgEnable command. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory using the cfgSave switch:admin> fazonedelete "Blue_fazone" See Also fazoneAdd, fazoneCreate, fazoneRemove, fazoneShow 2-174 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 209
Assist host member (for example, "H{1,2}"). This operand is required. To remove "array2" from "Blue_fazone": switch:admin> fazoneremove "Blue_fazone", "array2" See Also fazoneAdd, fazoneCreate, fazoneDelete, fazoneShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-175 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 210
value defaults to 0. To display all Fabric Assist zones beginning with the letters A through C: switch:admin> fazoneshow "[A-C]*" fazone: Blue_fazone 1,1; array1; 1,2; array2 See Also fazoneAdd, fazoneCreate, fazoneDelete, fazoneRemove 2-176 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 211
processor, and GigPHY. Note This command is supported only on SilkWorm FR4-18i blades and SilkWorm 7500 platforms. Operands Examples This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 212
the test might report one or more of the following error messages: • CHIP_TEST_ERR • CHIP_TEST_CHIP_INIT_ERR • CHIP_TEST_IMAGE_VER_ERR • CHIP_TEST_TIMEOUT_ERR • CHIP_TEST_HEARBEAT_ERR • CHIP_TEST_INVALID_RESULT fcipPathTest 2-178 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 213
the designated loopback. Note This command is supported only on SilkWorm FR4-18i blades and SilkWorm 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 214
is for readability. fcipPathTest Examples To run the test on slot 2 with PHY loopback sending 10 frames: switch:admin> fcippathtest --slot 2 -path 2 -nframes 10 Running fcippathtest Test Complete: fcippathtest Pass 10 of 2-180 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 215
query from this switch. To display the LUN information: switch:user> fclunquery Number of LUNs returned by query: 1 LUN ID: 0x00 To display the LUN information of a list of port WWNs: switch switch: switch:admin> fclunquery -s The following WWNs will be used for any lun query from this switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 216
data-dependent problems in the fabric link. The pattern bytes are specified as hexadecimal characters. For example, -p ff causes the request frame to be filled with all 1s. -b Specifies to bypass the zone check functionality. 2-182 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 217
one device that accepts the request and another device that does not respond to the request: switch:admin> fcping 0x020800 22:00:00:04:cf:75:63:85 Source: 0x20800 Destination: 22 = 0/0/0 usec See Also gettimeofday, ping Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-183 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 218
of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To clear the FCPD debug information log: switch:admin> fcplogclear See Also fcpLogDisable, fcpLogEnable, fcpLogShow 2-184 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 219
of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To disable the FCPD debug information log: switch:admin> fcplogdisable See Also fcpLogClear, fcpLogEnable, fcpLogShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-185 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 220
information logged for FCPD. Debug information logging is enabled by default. Note The execution of this command is subject to Admin Domain log: switch:admin> fcplogenable See Also fcpLogClear, fcpLogDisable, fcpLogShow 2-186 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 221
device probing. Operands none Examples To display the FCPD debug information log: switch:admin> fcplogshow Time Stamp Event Port file&lineno arg0 arg1 arg2 arg3 arg4 See Also fcpLogClear, fcpLogDisable, fcpLogEnable Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-187 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 222
the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is required. To display the FCP probe information: switch:admin> fcpprobeshow portLoginShow, portLogShow 2-188 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 223
port to display, followed by a slash (/). portnumber Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is required. To display the FCP RLS information: switch:admin> fcprlsshow 2/5 0xda 0xdc link fail 0 0 loss sync - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 224
][-unit number] Description reached (0x80000000 for a 32-bit register). For example, supported only on SilkWorm FR4-18i blades and SilkWorm 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 225
fcrChipTest 2 Examples To run all tests on slot 7 and FC Router FPGA 1: switch:admin> fcrchiptest --slot 7 -unit 1 -testtype 0 Running fcrchiptest Test Complete: fcrchiptest fcrPathTest, miniCycle, portLoopbackTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-191 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 226
fabric is the fabric attached to the U_Ports-for example, E/F_Ports- of this switch. The backbone fabric ID must be unique across all FC Routerconnected fabrics. To Also fcrDisable, fcrEnable, switchDisable, switchEnable 2-192 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 227
If an XPath OS switch is in the BB, service Operands none Examples To disable the FC Routing service: fcr:admin> fcrdisable FC Routing service is disabled See Also fcrConfigure, fcrEnable, fosConfig, switchDisable, switchEnable, switchShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 228
fcrenable Description Use this command to enable the Fibre Channel (FC) Routing service on a switch. In Fabric OS v5.1 the FC Routing service is enabled by default. In Fabric OS v5.2 the FC Routing service is disabled by default, and this commmand must be executed to enable it. Use fosConfig - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 229
IP address and switch name of the 32.156.31 "mojo_5" 5 95 10:00:00:05:1e:37:00:45 10.32.156.31 "mojo_5" 6 95 10:00:00:05:1e:37:00:45 10.32.156.31 "mojo_5" See Also fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 230
Router FPGA and the central ASIC. Synopsis fcrpathtest [--slot slotnumber][-unit number][-path mode][-nmegs count] Description Use this command to verify the , ... 0x78, 0x78, 0x78, 0x78, ... 0xbc, 0xbc, 0x23, 0x47, ... 2-196 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 231
, 0x6e, 0x9a, ... Note This command is supported only on SilkWorm FR4-18i blades and SilkWorm 7500 platforms. Operands Examples This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 232
this FC Router. The default output displays only physical -w operands allow searching for physical devices based on fabric ID or port World Wide number of times the device has attempted login. Local failure counter represents the number failure counter represents the number of times the device - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 233
:0e 0100ef 3 50:05:07:65:05:84:0b:83 0100e8 Total devices displayed: 3 See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-199 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 234
their slots using the -r operand and try again." is displayed if all slots are used for the specified edge fabric. 2-200 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 235
-r 5 00:11:22:33:44:55:66:77 WWN deleted from proxy device slot See Also fcrPhyDevShow, fcrProxyDevShow, fcrXlateConfig, lsanZoneShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-201 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 236
the same backbone fabric as this FC Router. The default output displays only proxy device information relevant to this FC by fabric. Search parameters -f and -w allow searching for proxy devices based on fabric ID or port WWN. "No proxy device found" is Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 237
2 Examples To display the proxy devices relevant to this FC Router: switch:admin> fcrproxydevshow Proxy WWN Proxy Device Physical State Created PID Exists PID in , fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-203 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 238
system reboots, because the phantom switch might still be accessible through other switches. Across the switch reboot, the allocation starts from the next usable WWN base from the pool and not from purposes. Operands none 2-204 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 239
13 | 6 34 14 | 6 34 15 | 6 34 16 | 8 34 17 | 8 34 18 | 8 34 19 | 8 34 20 | 8 34 21 | 8 34 22 | 8 34 23 | 8 34 See Also fcrFabricShow, fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-205 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 240
> fcrrouterportcost Port Cost 7/3 1000 7/4 1000 7/9 1000 7/10 1000 7/16 10000 10/0 10000 To display the cost of one EX_Port: fcr:admin> switch:admin> fcrrouterportcost 7/10 Port Cost 7/10 1000 2-206 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 241
: Enter commands in lowercase only; mixed case is for readability. fcrRouterPortCost 2 To set the cost of an EX_Port: fcr:admin> switch:admin> fcrrouterportcost 7/10 10000 See Also switchShow, fcrRouteShow, portCfgEXPort Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-207 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 242
imported fabrics, creating a meta-SAN. There are FC Router ports backbone/intermediate fabrics are currently not supported, an NR_Port provides a path NR_Port FCRP Cost WWN of Principal Fabric Id PID Switch in the Dest. Fabric 4 640000 1000 10:00 Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 243
domain ID when the translate domain is not active and is persistently saved. The principal switch attempts to provide the translate domain with the requested domain ID, but might not provide it ) of the translate phantom. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-209 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 244
created in fabric 2 that represents remote fabric 3: fcr:admin> fcrxlateconfig -r 2 3 xlate domain deleted See Also portCfgEXPort, portCfgVEXPort, portDisable, portEnable, portShow 2-210 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 245
by semicolons and enclosed in quotation marks; for example, "SCC;DCC". Supported policies are Switch Connection Control (SCC), Device Connection Control (DCC) and Password (includes account database and password policies) (PWD). --fabwideset policy_set Sets the Fabric-Wide Consistency Policy - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 246
--localreject "SCC;DCC" Local Switch Configured to reject policies. To set the Fabric-Wide Consistency Policy to "strict" for SCC and "tolerant" for DCC: switch:admin> fddcfg --fabwideset "SCC:S;DCC" See Also distribute 2-212 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 247
that may be in place. Operands Examples none To display the FDMI cache: switch:admin> fdmicacheshow Switch entry for domain 3 state: known version: v310 wwn: 10:00:00: devices on the switch is 1 See Also fdmiShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-213 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 248
Manufacturer: Emulex Network Systems Serial Number: 0000c9259b96 Model: LP9000 Model Description: Emulex LightPulse LP9000 1 Gigabit PCI Fibre Channel Adapter Hardware Version: 00000001 Driver Version: SLI-2 SW_DATE:May 3 2002, v5-2.11a2 **CT_TEST 1** Firmware Version: 03814101 OS Name and Version - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 249
database: switch:user> ficonclear RLIR successfully clear local RLIR Database. To clear RNID database: switch:user> ficonclear RNID successfully clear not current entries from local RNID Database. See Also ficonHelp, ficonShow Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 250
switch: switch:admin> ficoncupset fmsmode enable fmsmode for the switch is now Enabled To set ASM bit in the mode register for the switch: switch:admin> ficoncupset modereg ASM 1 Active=Saved Mode bit is set to 1 See Also ficoncupshow 2-216 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 251
mode DCAM Director clock alert switch: switch:user> ficoncupshow modereg POSC UAM ASM DCAM ACP HCP 1 0 1 1 1 0 To display ASM bit in the mode register for the switch: switch:user> ficoncupshow modereg ASM ASM --1 See Also ficoncupset Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 252
ficoncupset Sets FICON-CUP parameters for a switch ficoncupshow Displays FICON-CUP parameters for a switch ficonhelp N/A ficonshow Displays contents of the specified FICON management database See Also none 2-218 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 253
[unit number] FRU Part Number Displays the FRU part number. FRU Serial Number Displays the FRU serial number. Incident Count Displays the incident count. This number increases by 1 for each incident within the individual switch. Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 254
code. Model Number Displays the model number. Node Parameters Same as Parameters. Parameters Displays the node type for the switch in three FC-4 support not specified. 0xa0 Reserved. 0xc0 Reserved. 0xe0 Vendor specific. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 255
0x07 Terminal - Full screen if it support only. 0x09 Reserved. 0x10 Switch, if it is a switch switch. 0xID CHIPID if channel port has registered with the switch. 0xPN If switch has registered with the channel, PN represents the FL port number. Part Number Displays the switch chassis part number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 256
is required. fabric Specify fabric to display both local and remote information; if omitted, only members of the named database that are local to the switch on which the command is issued displays. 2-222 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 257
10:00:00:60:69:80:1e:4e 0x00 0x200a00 Type number: SLKWRM Model number: 48K Manufacturer: BRD Plant of Manufacture: CA Sequence Number: 0RB030000082 tag: 00ff } } The Local switch RNID database has 1 entries. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-223 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 258
:1e:4e FRU part number: FRU serial number: 23000000602 FL2L0001071 {Listener Port Type Listener PID Listener Port WWN N 0x502b00 50:05:07:64:01:00:15:8d } } {FRU Failure [3]: Power Supply[4] failure occurred on Mon Jan 13 12:11:38 2003 Fmt Protocol Domain Fabric WWN Switch WWN 0x18 FICON - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 259
A-based filtering. FLTACT_LIST_B Action to handle the subgroup B-based of Filter Test Numbers, Definitions, and Action Types Number Filter Definition Action Type Zone A|B match and AL_PA match Discard Note This command is supported only on SilkWorm 3250, 3850, 3900,12000, and 24000 platforms - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 260
definition memory. The default value is 0. The maximum offset number is set if the specified number is larger than the limit. To run a frame filter test: switch:admin> filtertest -txports information. See Also itemList 2-226 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 261
switches the primary partition (with the old firmware) to the secondary, and the secondary partition (with the new firmware) to the primary. The default partition (with new firmware) to the secondary and commits the new firmware to both partitions version of the firmware: switch:admin> firmwarecommit - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 262
to the BP blades if there is a mismatch with the CP firmware. For each non-director-class platform in your fabric, complete all firmware download changes before issuing firmwareDownload on the next switch to ensure a nondisruptive download. The command supports both noninteractive and interactive - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 263
Note: Enter commands in lowercase only; mixed case is for readability. firmwareDownload 2 Note The execution of this command is subject to Admin Domain restrictions that may be in place. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-229 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 264
, you must issue the reboot command manually to activate the downloaded image. If autoreboot mode is enabled, the switch reboots automatically after the firmwareDownload command has been run. -n Specify this operand to deactivate autocommit mode. By default, after running this command and after - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 265
only; mixed case is for readability. firmwareDownload 2 Examples To download the firmware to an HA switch: switch:admin> firmwaredownload 192.168.166.30,johndoe,/pub/dist/release.plist,12345 The following BP blades are installed in the system. Slot Name Versions Scope of Impact 2 FR4 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 266
. [6]: Fri Feb 15 22:25:46 2008 The internal firmware image is relocated successfully. [7]: Fri Feb 15 22:25:46 2008 Firmwaredownload command has completed successfully. Use firmwareshow to verify the firmware versions. 2-232 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 267
CP. [16]: Mon Dec 19 19:01:39 2005 Slot 5 (CP0, active): Firmwaredownload command has completed successfully. Use firmwareshow to verify the firmware versions. See Also firmwareCommit, firmwareDownload, firmwareRestore, firmwareShow Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 268
place. Operands Examples none To restore the former active firmware image: switch:admin> firmwarerestore Restore old image to be active 48:54 2001... Doing firmwarecommit now. Please wait ... See Also firmwareCommit, firmwareDownload 2-234 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 269
Operands Examples none To display the firmware version of a SilkWorm switch: switch:admin> firmwareshow Primary partition: v5.1.0 Secondary Partition: v5.1.0 To display the firmware version of a SilkWorm director with FR4-18i blades installed: switch:admin> firmwareshow Slot Name Primary - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 270
; that is, a short wavelength SFP (switch) port is connected to another short wavelength test is running. Note This command is supported only on SilkWorm 200E, 3250, 3850, the frame. The data pattern is generated based on data type. Some data types might Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 271
Specify the number of words in the test packet payload. If pattern_size is omitted, the default value is 512. This operand is optional. To run fportTest on a switch: switch:admin> ERR_STATS_ENCOUT ERR_STATS_TRUNC Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-237 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 272
STATS_FTX TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. See Also crossPortTest, itemList, loopPortTest, portTest, spinFab 2-238 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 273
feature on the switch. Valid values for feature are: • fcr The FC Routing service will be enabled on this switch. The FC Routing service is by default disabled on a new switch with Fabric OS v5 . Take these ports offline Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-239 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 274
service: switch:admin> fosconfig --enable iscsi iSCSI service is enabled To disable the iSCSI service: switch:admin> fosconfig --disable iscsi iSCSI service is disabled See Also fcrConfigure, iscsiCfg, iscsiPortCfg, isnscCfg, switchShow 2-240 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 275
to guide the power cycle, or CP failover, please follow the recovery procedure in Core Switch WWN Card Removal and Replacement document. Do you wish to continue [y/n]? y Backing up WWN card data, please wait about 25 seconds for further instruction Manual Publication Number: 53-1000240-01 2-241 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 276
number of local switch. switchOnline State of the local switch. domainValid TRUE if the domain of the local switch is currently confirmed. isl_ports Bit map of all the ISL. Bit positions correspond to the default . 2-242 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 277
fspfShow 2 Operands Examples none To display FSPF protocol information: switch:admin> fspfshow version = 2 domainID = 131 switchOnline = fabP: event_sch = 0x0 See Also bcastShow, topologyShow, uRouteShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-243 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 278
in Fabric Watch: switch:admin> fwalarmsfilterset Committing configuration...done. FW: Alarms are disabled switch:admin> fwalarmsfilterset 1 Committing configuration...done. FW: Alarms are enabled See Also fwAlarmsFilterShow 2-244 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 279
. Operands Examples none To display the status of alarm filtering in Fabric Watch: switch:user> fwalarmsfiltershow FW: Alarms are enabled switch:user> fwalarmsfiltershow FW: Alarms are disabled See Also fwAlarmsFilterSet Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-245 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 280
is subject to Admin Domain restrictions that may be in place. Operands Examples none To initialize all classes under Fabric Watch: switch:admin> fwclassinit fwClassInit: Fabric Watch is updating... fwClassInit: Fabric Watch has been updated. See Also fwConfigReload, fwConfigure, fwShow 2-246 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 281
Examples none To reload the saved Fabric Watch configuration: switch:admin> fwconfigreload fwConfigReload: Fabric Watch configuration reloaded See Also configDownload, configUpload, fwClassInit, fwConfigure, fwShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-247 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 282
modify threshold information for the Fabric Watch configuration. Switch elements monitored by Fabric Watch are divided into command requires a Fabric Watch license. Not all platforms support fans or power supplies. If you attempt to configure values for these Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 283
operands: --enable --port portNumber Enables all thresholds associated with a certain port. --disable --port portNumber Disables all thresholds associated with a certain port. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-249 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 284
case is for readability. fwConfigure Examples To configure thresholds: switch:admin> fwconfigure 1 : Environment class 2 : SFP 1 : Temperature 2 : Fan 3 : Power Supply 4 : return to previous page Select , fwShow 2-250 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 285
actions. Based on Power Supply Alarm Action: (0..17) [0] Fan Alarm State: (0..31) [0] Fan Alarm Action: (0..17) [0] WWN Alarm State: (0..31) [0] WWN Alarm Action: (0..17) [0] Fru configuration successfully changed See Also fwConfigure, fwMailCfg Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 286
level to default Show thresholds monitored or port persistence time Show sensor readings Set switch status policy parameters Show switch status policy parameters Show overall switch status Show switch temp readings See Also none 2-252 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 287
of the Fabric Watch email alert in the switch. Switch elements monitored by Fabric Watch are divided into classes, and email alerts are based on the classes. Each class can configure : (0..13) [11] 1 (continued on next page) Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-253 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 288
an item => : (0..13) [11] 1 Mail To: [NONE] [email protected] Email Alert configuration succeeded! See Also dnsConfig, fwConfigure, ipAddrSet, ipAddrShow 2-254 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 289
based on the following contributors: Port Errors LFA Number of link loss occurrences exceeded limit for time period LSY Number out of specification SRX SFP receive power is out of specification STX SFP transmit power is out of specification SCU SFP Manual Publication Number: 53-1000240-01 2-255 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 290
001:11 026 F HEALTHY 001:11 027 F HEALTHY 001:11 028 E HEALTHY 001:11 029 E HEALTHY 001:11 031 F HEALTHY 001:11 See Also switchStatusShow 2-256 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 291
AD-aware environment, this command is allowed only if the local switch is a member of the current Admin Domain. Note This command 0 0 0 100 6 U_PORT 0 0 0 100 7 U_PORT 0 0 0 100 See Also portShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-257 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 292
time period in which a port must be persistently in a state before being actually being recognized as such. To set message levels and port persistence time: switch:user> fwset --port --persistence 18 See Also fwShow 2-258 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 293
this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To set alarm levels to custom values: switch:admin> fwsettocustom Committing configuration...done. See Also fwSetToDefault Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-259 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 294
command is subject to Admin Domain restrictions that may be in place. Operands Examples none To return alarm levels to default values: switch:admin> fwsettodefault Committing configuration...done. See Also fwSetToCustom 2-260 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 295
must be persistently in a state before being marked as such. --disable --port Displays the ports that have all associated thresholds disabled. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-261 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 296
readability. fwShow Examples To display thresholds and port persistence time: switch:user> fwshow 1 : Show class thresholds 2 : Detail => : (1..12) [11] 1 1 : Temperature 2 : Fan 3 : Power Supply 4 : return to previous page Select an area => : (1..4) [4] 2 Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 297
are registered. switch:user> fwshow --port --persistence FW: current port persistence time = 18s switch:user> fwShow --disable --port Port Threshold Status 1 disabled See Also fwClassInit, fwConfigReload, fwConfigure, fwSet Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 298
Move the cursor right a Append i Insert x Delete u Undo Operands none Examples To display previous shell commands: switch:admin> h 1 version 2 switchshow 3 portdisable 2 4 portenable 2 5 switchshow See Also none 2-264 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 299
The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To disable the High Availability feature: switch:admin> hadisable HA is disabled See Also haEnable Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-265 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 300
feature in the switch. Synopsis hadump switch. This command displays the following information: • Local CP state (slot number and CP ID) • Remote CP state (slot number has discovered a problem with the blade. The logs Channel addresses configured for the switch. • Additional internal HA state - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 301
CP (Slot 5, CP0): Non-Redundant ipaddrshow: SWITCH Ethernet IP Address: 10.33.54.251 Ethernet Subnetmask 48.1 Backplane IP address of CP0 : 10.0.0.5 Backplane IP address of CP1 : 10.0.0.6 --- --- See Also haFailover, haShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 302
of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To enable the High Availability feature in the switch: switch:admin> haenable HA is enabled See Also haDisable 2-268 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 303
. To reboot a single logical switch on this system, use the switchreboot command while logged in to that logical switch. Are you sure you want to fail over to the standby CP [y/n]? See Also haDisable, haEnable, haShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-269 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 304
(slot number and CP ID), warm or cold, recovering or recovered • Remote CP state (slot number and CP health diagnostic has discovered a problem with the blade. The logs should be checked disruptive. Note This command might not be supported on non-bladed systems. Note The execution of this command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 305
switch:admin> hashow Local CP (Slot 6, CP1): Active, Warm Recovered Remote CP (Slot 5, CP0): Standby, Failed Backplane PCI fail, severity: CRITICAL HA enabled, Heartbeat Up, HA State not in sync See Also haDisable, haEnable, haFailover Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 306
is subject to Admin Domain restrictions that may be in place. Examples To enable the HA state synchronization: switch:admin> hasyncstart HA State synchronization has started See Also haFailover, haShow, haSyncStop 2-272 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 307
of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To disable the HA state synchronizing process: switch:admin> hasyncstop See Also haFailover, haShow, haSyncStart Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-273 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 308
name, with or without quotation marks. This operand is optional. Examples To display help information for the help command: switch:admin> help help See Also diagHelp, fwHelp, licenseHelp, perfHelp, routeHelp, zoneHelp 2-274 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 309
FRU insertion or removal event: switch:admin> historylastshow POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001 Factory Part Number: 60-0001536-02 Factory Serial Number: 1013456800 Records: 11 See Also historyShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-275 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 310
the oldest messages in the log. First-in mode Once the log is full, all additional logs are discarded so that the first set of logs to : switch:admin> historymode History Mode is: Rotating. See Also historyLastShow, historyShow 2-276 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 311
and third lines of a record respectively contain the factory part number and factory serial number, if applicable: Factory Part Number xx-yyyyyyy-zz or Unknown Factory Serial Number xxxxxxxxxxxx or Unknown SilkWorm directors support 100 history log entries; all other platforms, which contain - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 312
Slot 3 Inserted at Tue Aug 14 13:53:40 2001 Factory Part Number: 60-0001532-03 Factory Serial Number: 1013456800 CP BLADE Slot 6 Inserted at Tue Aug 14 13:59:50 2001 Factory Part Number: 60-0001604-02 Factory Serial Number: FP00X600128 POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 313
Description Use this command to display the version of the Java plug-in supported by Web Tools. This command also displays the URL from which the Operands Examples none To display the Java plug-in version: switch:admin> httpcfgshow Current HTTP configuration javaplugin.version = 1,3,1 javaplugin. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 314
or stopped Z a defunct ("zombie") process UID The effective user ID number of the process PID The process ID of the process PPID The process process C Processor utilization for scheduling PRI Priority number of the process; higher numbers mean lower priority NI Nice value used in - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 315
has the following operand: processID Specifies the process name or process ID for the process to display. To display information about process ID 433: switch:admin> i 433 F S UID PID PPID C PRI NI ADDR SZ WCHAN TTY TIME CMD 000 S 0 433 1 0 69 0 - 1283 5c64 ? 00:00:02 fabricd See Also - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 316
switch and SilkWorm 24000 and 48000 directors that use a Broadcom PHY transceiver. This command is not supported on SilkWorm 3016 switches. The internal Ethernet in the IBM eServer BladeCenter chassis operates exclusively in fixed 100-Mbit full Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 317
, n): [no] n Force 100 Mbps / Half Duplex (yes, y, no, n): [no] n Force 10 Mbps / Full Duplex (yes, y, no, n): [no] n Force 10 Mbps / Half Duplex (yes, y, no, n): [no] y Committing configuration...done. See Also ifModeShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-283 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 318
eth0" or eth0, where eth is the network interface and 0 is the physical unit. To display the link operating mode for the "eth0" Ethernet interface: switch:admin> ifmodeshow eth0 Link mode: negotiated 100baseTx-HD, link ok MAC Address: 00:60:69:D0:24:40 See Also ifModeSet 2-284 Fabric OS Command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 319
: idbP Pointer to IDB. nghbP Pointer to neighbor data structure. ifNo Interface number. masterPort Port number of the trunk master port, if present, of the trunk group of which this port is a part. defaultCost Default cost of sending a frame over the ISL connection to this interface. cost - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 320
neighbor switch. Number of attempted transmissions of LSAs to the neighbor switch. Number of LSAs transmitted to the neighbor switch. Note The execution of this command is subject to Admin Domain restrictions that may be in place. 2-286 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 321
bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, the interface information for all ports is displayed. When no slot number and port number are specified, this command displays the interface information for all ports on the switch 16 Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 322
nCmdAcc = 7 nInvCmd = 0 nHloIn = 2 nInvHlo = 0 nLsuIn = 2 nLsaIn = 3 attHloOut = 2 nHloOut = 2 attLsuOut = 3 nLsuOut = 3 attLsaOut = 2 nLsaOut = 2 See Also nbrStateShow, portShow, switchShow 2-288 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 323
disabled, configuration parameters are returned to their default states and can be changed using configure. Note Only Port World Wide Name zoning is supported in interoperability mode. Note FC Routing services are not available in interop mode. Switches connected to edge fabrics are not available - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 324
(yes, y, no, n): [no] y Interopmode is disabled. Note: You MUST reboot this switch for the new change to take effect. To see connections on a switch that is operating in interop mode (ports 8/0, 8/1 show the connections to 2-290 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 325
for readability. interopMode 2 the Brocade fabric; ports 8/2, 8/3 show 94 8 14 045e00 id N2 No_Light 95 8 15 045f00 id N2 No_Light 208 8 16 04d000 -- -- Offline Disabled (Persistent) 209 8 17 04d100 -- -- Offline Disabled OS Command Reference Manual Publication Number: 53-1000240-01 2-291 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 326
command to turn off the IOD option. The IOD option is turned off by default; however, if the IOD option was turned on using iodSet, this command : switch:admin> iodreset switch:admin> iodshow IOD is not set See Also iodSet, iodShow 2-292 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 327
are not delivered out-of-order, even during fabric topology changes. The default behavior is for the IOD option to be off. This command should be option: switch:admin> iodset switch:admin> iodshow IOD is set See Also iodReset, iodShow Fabric OS Command Reference Manual Publication Number: 53- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 328
Use this command to display whether the IOD option is enabled or disabled. Operands none Examples To display the current setting of the IOD option: switch:admin> iodshow IOD is not set See Also iodReset, iodSet 2-294 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 329
for the Ethernet IP address, Ethernet subnetmask, host name, and gateway IP address. Valid switch and CP numbers depend on the platform from which the command is being run. For a nonchassis-based switch, the command ignores all options. The command prompts for the Ethernet IP address, Ethernet - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 330
case is for readability. ipAddrSet Examples To set the IP address details for switch number 1 on a chassis-based system: switch:admin> ipaddrset -sw 1 Ethernet IP Address [192.168.166.148]: .1]: DHCP [Off]: on ipAddrShow 2-296 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 331
(0 or 1). -sw sw_number For dual-domain systems, this specifies the switch number to display (0 or 1). If no operands are specified, the command displays all the IP addresses configured in the system. For nonchassis-based switches, this command ignores all operands. To display the IP address for - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 332
--clear initiator [-h ] iscsicfg --show initiator [-i initiator_name] [-h ] iscsicfg --abort transaction -x transaction_id [-h ] iscsicfg --show transaction [-h ] iscsicfg --clear all [-h ] iscsicfg --commit all [-f ] [-h ] 2-298 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 333
memory. This triggers the propagation of changes to all iSCSI-enabled switches and blades in the fabric. Changes will not take effect until a is enforced, based on the login frame from the host. • --delete tgt -t target_name [-h ] Fabric OS Command Reference Manual Publication Number: 53-1000240- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 334
the DD is deleted. If a DD to be deleted is a part of a DD set, the set shall be modified to reflect the only IQN format is supported. Multiple entities may be specified as a commaseparated list. The IQN may be a maximum of 64 characters. • --add Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 335
auth -u user1 -s abcdefg123 The operation completed successfully. To modify a CHAP entry associated with an existing user: switch:admin> iscsicfg --modify auth -u user1 -s newsecret The operation completed successfully. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-301 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 336
-a CHAP The operation completed successfully. To display the target database switch:admin> iscsicfg --show tgt Number of records found: 2 Name: State/Status: iqn.2005-10.com.brocade.tgt1 Offline/Defined Name: State/Status: iqn.2222-23.com.brocade:21:00:00:20:37:df:83:fc Online/Committed To - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 337
To display LUN maps: switch:admin> iscsicfg --show lun Number of records found: 2 Target: iqn.2005-10.com.brocade.tgt1 Number of LUN Maps: 1 switch:admin> iscsicfg --create ddset -n myddset -d mynewdd The operation completed successfully. Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 338
--show fabric Switch ID Switch WWN * 1 10:00:00:60:69:e4:20:1e Switch State iSNSC -- Disabled Aggregated iSCSI database state for fabric: In Sync Displays switches that are capable of propagating iSCSI data base. 2-304 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 339
--show initiator Number of records found: 1 Name iqn.1991-05.com.brocade:initiator1 IP Address 172.16.14.101 switch:admin> iscsicfg --show initiator -i iqn.1991-05.com.brocade:initiator1 Initiator details are: Name IP Address iqn.1991-05.com.brocade:isi154116.englab.brocade.com 172.16.14.101 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 340
-unit gbeports Specifies the GE port to test. By default all the GE ports in the specified slot slotnumber will be used. This number will be between 0 and 7. 8 will mean all ports. Examples To run iscsichiptest: switch:admin> iscsichiptest --slot 7 -unit 1 -testtype 0 Running iscsichiptest Test - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 341
support commands: switch:admin> iscsihelp fclunquery Display a list of LUNs of FC target(s). fosconfig Enable/disable FabOS services Port switchshow Display the number of sessions on each iSCSI port See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-307 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 342
of frames to send. The test will progress until the specified number of frames has been transmitted on each port. The default value is 100. Examples To run iscsipathtest: switch:admin> iscsipathtest --slot 2 -path 2 -nframes 10 Running iscsipathtest Test Complete: iscsipathtest Pass 10 of 10 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 343
, 2048, 4096, 8192, 16384, and 32768. --clearstats Clears port-level iSCSI statistics on the specified port. --default Resets the port to the default values. See the "Description" section for the list of default values. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-309 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 344
. NOTE: This parameter only supports FC4-16IP blades in SilkWorm 48000 directors. • geport Specifies the port number of a GbE port to be configured in the specified slot. Use -h on any option to display the help text for it. To modify the port parameters: switch:admin> iscsiportcfg --modify 7/ge2 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 345
2 To display the port information in verbose mode: switch:admin> iscsiportcfg --show 7/ge0 The configured port parameters 0 1 1 0 0 0 0 0 0 0 0 0 17 2576 17 1352 Session details: Session Number: iSCSI Session Type: Initiator Name: Target Name: ISID: 1 Normal iqn.1991-05.com.microsoft:win-iscsi - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 346
. • -i initiator_iqn Selects only sessions that match the given initiator IQN. • -t target_iqn Selects only sessions that match the given target IQN. 2-312 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 347
switch:admin> iscsisessioncfg --show Number of sessions found: 1 Session 1 Details: Initiator Name: iqn.1991-05.com.init:6a3-iscsi-053.englab.brocade.com Target Name: iqn.2002-12.com.brocade 1 16 Default time to retain 20s 60s Default time Manual Publication Number: 53-1000240-01 2-313 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 348
, iscsiCfg, iscsiPortCfg 23100 855685264 851487 882055140 431295 878756240 425006 855888688 6787 3375 16313 420747 6659 7350 420686 417656 3375 7234 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2-314 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 349
. The default prefix is iqn.2002-12.com.brocade. Note brocade To change the target name prefix: switch:admin> iscsitargetname --modify -u iqn.2002-10.com.brocade The operation completed successfully See Also fosConfig, iscsiCfg, iscsiPortCfg Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 350
:-------". Operands none Examples To display the ISL connections for the switch: switch:user> islshow 1: 33-> 29 10:00:00:60:69:80: 01:0b:4a 6:162->160 10:00:00:60:69:e2:09:fa 7:208-> 16 10:00:00:05:1e:37:02:73 3 Termonator8 4 Dazzler_1 15 Stealth_05 5 Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 351
blade in a chassis and the port number of a GbE port in an iSCSI blade. NOTE: This parameter only supports FC4-16IP blades in SilkWorm 48000 directors. --s server_ip Specifies the IP address in dotted-decimal form. To set the IP address of the iSNS server (GbE port attached): switch switch:admin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 352
Enter commands in lowercase only; mixed case is for readability. isnscCfg To trigger a re-registration of iSNS ojects: switch:admin> isnsccfg --reregister Initiated re-register of iSNS objects with iSNS server See Also none 2-318 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 353
16-port/blade system. On that same system, "1/0, 16, 32" is not a valid list: even though it is legal syntax, the ports do not exist. • If no slot number is specified, all lists except user port lists will use the default Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-319 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 354
on the current blade (specified with --slot number) are tested. Blade Blade ports, internal and external ports UPORTS Switch User ports, ports with external connections QUADS Blade Quadrants, group of (normally four) ports CHIPS Blade Chips, ASICs within a blade MINIS Blade Mini-switches - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 355
terminate an open telnet connection: switch:admin> killtelnet Collecting login information 16.00s 192.168.130.29 6:29pm 2 admin0 pts/1 3.00s 192.168.130.29 6:31pm Enter Session Number Session Number to terminate (q to quit) q Fabric OS Command Reference Manual Publication Number: 53- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 356
2 Note: Enter commands in lowercase only; mixed case is for readability. killTelnet See Also none 2-322 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 357
. Some features of the switch and the fabric to which it is connected are optional, licensed products. Without a license installed for such products, their services are not available. A license key is a string of approximately 16 upper- and lowercase letters and numbers. Case is significant. The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 358
licenseAdd licenseIdShow licenseRemove licenseShow Add a license to this switch Show system license ID Remove a license from this switch Show current licenses See Also licenseAdd, licenseIdShow, licenseRemove, licenseShow 2-324 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 359
switch and the fabric are optional, licensed products. Without a license installed for such products, the services provided by these features are not available. For dual-domain systems, a single license enables both logical switches display the license ID: switch:admin> licenseidshow a4:f8: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 360
. This operand is required. To remove a license key from the switch: switch:admin> licenseremove "bQebzbRdScRfc0iK" removing license key "bQebzbRdScRfc0iK" See Also licenseAdd, licenseHelp, licenseIdShow, licenseShow 2-326 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 361
none To display the installed license keys on a switch: switch:admin> licenseshow bQebzbRdScRfc0iK: Web license Zoning license SybbzQQ9edTzcc0X: Fabric license See Also licenseAdd, licenseHelp, licenseIdShow, licenseRemove Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-327 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 362
a dimensionless positive number. The FSPF protocol compares the cost of various paths between a source switch and a destination switch by adding the sec ISL 500 This command can be used to set a non-default, "static" cost for any port except EX/VEX ports. ( Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 363
2/4 500 switch:admin> linkcost 2/4 Interface2/4 Cost switch:admin> linkcost 2/4 0 switch:admin> linkcost 2/4 500 (STATIC) Interface2/4 Cost 1000 See Also interfaceShow, lsDbShow, topologyShow, uRouteShow, fcrRouterPortCost Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 364
you to access commands that you cannot access at your current user level. Operands none Examples To log in as admin from the login user: switch:user> login login: admin Password:xxxxxx See Also logout 2-330 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 365
command is accepted as a synonym for logout, as is Ctrl-D at the beginning of a line. Operands none Examples To log out from an rlogin session: switch:admin> logout See Also login Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-331 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 366
meaning that a short wavelength SFPed (switch) port is connected to another short create the frame. The data pattern is generated based on each data type. Some data types might users and technical support only. This command is supported only on SilkWorm Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 367
-nframes count Specify the number of times (or number of frames per port) to execute this test. The default value is 10. The byte (default) 2 word 4 quad This operand is optional. To perform a loopback port test: switch:admin OS Command Reference Manual Publication Number: 53-1000240-01 2-333 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 368
is for readability. lsanZoneShow lsanZoneShow Displays logical SAN zone information. Synopsis lsanzoneshow [-s] [-f The default output displays only WWNs of the zone members. Search parameters -f , -w, and -z allow searching for LSAN zones based on fabric Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 369
readability. lsanZoneShow 2 Examples To display the LSAN zones: switch:admin> lsanzoneshow Fabric ID: 4 Zone Name: lsan_fcr10_0 50 switch# See Also fcrFabricShow, fcrPhyDevShow, fcrProxyDevShow, fcrRouteShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-335 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 370
16 lsDbShow Display Fields Field Description Domain Domain number described by this LSR. A (self) keyword after the domain number indicates that LSR describes the local switch. lsrP Pointer to LSR. earlyAccLSRs Number 2-336 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 371
NB_ST_FULL state. Always 0. ID of this link. It is the domain number of the switch on the other side of the link. Port number on the local switch. Port number of the port on the other side of the link. Cost of this link. The default cost for a 1 Gbit/sec link is 1,000. Always 0. Always 1. Note - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 372
16, flags = 0x0 LinkId = 2, out port = 16 2, out port = 32, rem port = = 47, rem port = 48, cost = 500, costCnt = switch has sixteen links in NB_ST_FULL state, all of them are connected to switch 2. See Also interfaceShow, nbrStateShow 2-338 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 373
129740800 112562176 Swap: 0 0 switch:admin> memshow -m total used Mem: 123 107 Swap: 0 0 free 17178624 0 free 16 0 shared 0 buffers cached 139264 30396416 shared 0 buffers 0 cached 28 See Also saveCore Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-339 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 374
Runs a functional test of internal and external transmit and receive paths at full speed. Synopsis minicycle [--slot slotnumber][-nmegs count][-lb_mode mode][-spd_mode mode][-ports of RDRAM_PAT • 2112 bytes of BYTE_LFSR 2-340 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 375
is met: • The number of frames requested is met switch are faulty. The following operands are optional: --slot slotnumber Specifies the slot number on which the diagnostic operate. The ports specified are relative to this slot number. The default Bloom and Condor ASIC-based products, for which - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 376
. Specifies a list of blade ports to test. By default, all the blade ports in the specified slot 16-31 ASIC-pair 2: -ports 32-47 ASIC-pair 3: -ports 48-63 To run a functional test on slot 1 using external (SERDES) loopback: switch Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 377
readability. miniCycle 2 To run a functional test on ports 0, 1, 2, and 8 using port loopback: switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1 Back Plane Loop Back mode is ON. Running mini Cycle One TIMEOUT XMIT Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-343 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 378
to the Fabric OS Message Reference for more information. backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, crossPortTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest 2-344 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 379
blade default is 0 and designed to operate on fixed-port-count products. To display all index 1 ASIC pair properties: switch:user> minispropshow 1 -all slot: 1, miniS: 0 [2/16 miniS: 2 [2/16] (be,17) (be,16) (be,15) fe,8) slot: 1, miniS: 3 [2/16] (be - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 380
the supported MS capabilities for each switch in the fabric: Switch WWN 10:00:00:60:69:20:15:71 10:00:00:60:69:00:30:05 Capability Name 0x0000008f "switch1"* 0x0000008f "switch2" Capability Bit Definitions: Bit 0: Basic Config Service Supported. Bit 1: Platform Management Service Supported. Bit - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 381
SAN management application to retrieve and administer the fabric and interconnect elements, such as switches. This application is located at the Fibre Channel well-known address, 0xFFFFFA. If the MS ACL is empty (default Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-347 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 382
3 Delete member based on its Port/Node WWN select : (0..3) [1] 0 done ... See Also msCapabilityShow, msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable, msTdReadConfig, secPolicyShow 2-348 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 383
restrictions that may be in place. Operands Examples none To display the MS platform database for a fabric: switch:admin> msplatshow Platform Name: [9] "first obj" Platform Type: 5 : GATEWAY Number of Associated M.A.: 1 Associated Management Addresses: [35] "http://java.sun.com/products/plugin - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 384
place. Operands Examples none To display the MS platform service database control block: switch:admin> msplatshowdbcb Domain Worldwide Name Retry Count Exchange Status msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate 2-350 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 385
, this command can be issued only from the primary FCS switch. Note The execution of this command is subject to Admin Service Database!! See Also msCapabilityShow, msConfigure, msPlatShow, msPlatShowDBCB, msPlMgmtActivate, msPlMgmtDeactivate Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 386
in the fabric boot with the MS platform service enabled. By default, the MS platform service is disabled. Before issuing, run the msCapabilityShow command to verify all switches in the fabric support MS platform service; otherwise, the command fails. Note When security is enabled, this command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 387
entire fabric. This command deactivates the MS platform service for each switch in the fabric and commits the change to nonvolatile storage. Note When security is enabled, this command can be issued only from the primary FCS switch. This command is supported only in AD0 and AD255 contexts. Note The - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 388
power cycles and reboots. If the "ALL" operand is used, this command attempts to disable the topology discovery service on all switches in the fabric. Note When security is enabled, and using the "ALL" operand, this command can be issued only from the primary FCS switch. This command is supported - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 389
the fabric: switch:admin> mstdenable "ALL" Request to enable MS Topology Discovery Service in progress.... done. *MS Topology Discovery enabled locally. *MS Topology Discovery Enable Operation Complete!! See Also msTdDisable, msTdReadConfig Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 390
To display the status of the topology discovery service: switch:admin> mstdreadconfig *MS Topology Discovery is enabled. See Also msCapabilityShow, msConfigure, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable 2-356 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 391
Domain restrictions that may be in place. Operands Examples none To display current login information: switch:admin> myid Current Switch: switch Session Detail: switch (123.123.123.123) Active Redundant See Also version Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-357 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 392
To display information about switches directly connected to the local switch: switch:user> nbrstateshow 2/0 Local Domain ID: 1 Local Port Domain Remote Port State 16 2 48 NB_ST_FULL See Also interfaceShow 2-358 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 393
to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, FSPF statistics are reset. When this command is specified with no operand, the statistics are cleared for all interfaces. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 394
. nbrStatsClear Examples To reset the counters on a port: switch:admin> interfaceshow 1/0 idbP = 0x10050a38 Interface 0 data structure attLsaOut = 0 nLsaOut = 0 See Also interfaceShow, portShow, switchShow 2-360 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 395
between 0 and ff, with no spaces. PID must begin with 0x or 0X; otherwise, it will be interpreted as an alias. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-361 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 396
a320 To display all the device information matching the WWN "20:00:00:e0:8b:01:ce:d3": switch:user> nodefind 20:00:00:e0:8b:01:ce:d3 Remote: Type Pid COS PortName NodeName NL 020eef; Shared in Other AD: No Aliases: 2-362 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 397
Area: No Device Shared in Other AD: No Aliases: No match: To display all the device information matching the given no match: switch:user> nodefind abcd No device found. See Also aliShow, nsAllShow, nscamShow, nsShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-363 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 398
Device connected to the Nx_Port, using FLOGI to login to the switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch iSCSI Device connected to the iSCSI port The second part indicates the role of the device. Currently, four roles are - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 399
2 Examples Both an SCSI initiator and an SCSI target To display local NS information with aliases: switch:admin> nsaliasshow { Type Pid COS PortName NodeName TTL(sec) N 021200; 2,3;10:00:00:60 has 6 entries } Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-365 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 400
mixed case is for readability. nsAliasShow To display local NS information with aliases with the -r option: switch:admin> nsaliasshow -r { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69 6 entries } 2-366 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 401
display local NS information with aliases with the -r and -t options: switch:admin> nsaliasshow -r -t { Type Pid COS PortName NodeName SCR N : 10:00:00:60:69:00:02:d6 Device type: NPV Initiator Aliases: DeviceAlias NL 0214e2; 3;21:00:00:fa:ce Manual Publication Number: 53-1000240-01 2-367 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 402
ports supporting FC4 code," where x is the number of switch:admin> nsAllShow 8 { 0118e2 0118e4 0118e8 0118ef 0214e2 0214e4 0214e8 0214ef 8 FCP Ports } switch:admin> nsAllShow 5 { 011200 021200 2 FC-IP Ports } See Also nsShow, switchShow 2-368 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 403
and a list of devices for that domain number. For each device found in the devices list, the following information is displayed: Type U for unknown, N for N_Port, NL for NL_Port Pid The 24-bit Fibre Channel address COS A list of classes of service supported by the device PortName The device - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 404
switch and device entries discovered by the NS in the fabric: switch:admin> nscamshow nscam show for remote switches: Switch :ba Switch entry for 4 state rev owner switch:admin> nscamshow -t nscam show for remote switches: Switch Device type: Physical Initiator Switch entry for 4 state rev - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 405
Local Name Server The nsAllShow command displays information from all switches. Each line of output displays: Type U for unknown, N for N_Port, NL for NL_Port. PID 24-bit Fibre Channel address. COS List of classes of service supported by device. PortName Device port World Wide Name (WWN - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 406
the switch Virtual Contrived device by the switch NPV Device connected to the Nx_Port, using FDISC to log in to the switch iSCSI Device connected to the iSCSI port The second part indicates Unknown(initiator/target)". 2-372 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 407
ad:bc:04:6f:70 The Local Name Server has 6 entries } To display local NS information with -r: switch:admin> nsshow -r { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00: Name Server has 6 entries } Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-373 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 408
lowercase only; mixed case is for readability. nsShow To display local NS information with -r and -t: switch:admin> nsshow -r -t { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00: Also nsAllShow, switchShow 2-374 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 409
Fibre Channel address COS A list of classes of service supported by the device PortName The device's port World Wide following information (the switch automatically registers SCSI inquiry data for FCP target devices): • FC4 supported • IP address Manual Publication Number: 53-1000240-01 2-375 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 410
Target No remote zoned members To display information about all the online devices zoned with the given WWN: switch:admin> nszonemember 10:00:00:00:c8:23:0b:ad 3 local zoned members: Type Pid COS No remote zoned members 2-376 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 411
. nsZoneMember 2 To display each local device's online zoned device data: switch:admin> nszonemember -a Port: 4 Pid: 0xb00400 Aliases: ix360_131_201_6a Zoned Members the fabric. See Also cfgShow, nscamShow, nsShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-377 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 412
all switches except the primary FCS. Refer to the Secure Fabric OS Administrator's Guide for more information. A new password must follow these rules: • Have 8 to 40 characters • Must satisfy password policies configured by passwdCfg 2-378 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 413
no preceding input, accepts the default value (if applicable) and number of lowercase characters. Insufficient number of upper case lettersYou have entered a password that contains less then the minimum required number of uppercase characters. Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 414
the minimum ageing period expires. Password contains invalid charactersYou have entered a password that contains invalid characters. Refer to the Fabric OS Message Reference for more information. login, logout, passwdCfg 2-380 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 415
policies. Note When secure mode is enabled, passwdCfg is not supported. Use --set to configure the following password policies: • Password strength policy • Password history policy • Password expiration policy • Account lockout policy The password strength policy enforces a set of rules that new - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 416
minimum number of numeric digits that must occur in the password. The default value password for another user. When -maxpasswordage is set to a nonzero value, -minpasswordage must be set to a value less than or equal to -maxpasswordage. 2-382 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 417
password expiration. The default value is 0. -warning value Specifies the number of days prior to password expiration that a warning of password password configuration parameters: switch:admin> passwdcfg --set -uppercase 2 -maxpasswordage 90 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 418
of the following error messages displays: Command not supported passwdCfg is not supported when secure mode is enabled. minlength value out value must be between 0 and 999. invalid password expiration specification The -minpasswordage value or -warning value Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 419
). For each hop, the routing information output includes the following: Hop The hop number. The local switch is hop 0. In Port The port or area from which the switch receives frames. For hop 0, this is src_portnumber. For bladed systems, this is specified as the port index; otherwise, it is the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 420
path. Source route The source route option allows the user to specify a sequence of switches, ports, or areas that the pathInfo frame has to traverse to reach the destination. the destination), as a full route, or as an 2-386 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 421
apply to the portion(s) of the path described by domains, not to the part described by output ports or areas. Note Switches running pre 5.2 firmware cannot use ports > 256 as a destination port on a remote switch. Note The execution of this command is subject to Admin Domain restrictions that may - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 422
specific domain, using the command line (noninteractive mode): switch:admin> pathinfo 91 Target port is Embedded Hop In 0 B/s (64s) 5 5 5 5 Txcrdz (1s) 0 - 0 - Txcrdz (64s) 0 - 0 - F/s (1s) 1 1 0 0 F/s (64s) 0 0 OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 423
panic dump file available on the switch. If a panic dump file is optional operands: panic_dump_file Specify the full path name of a panic dump WatchDogRegister=0x0 Section=Startup time: Tue Dec 3 16:06:11 UTC 2002 Kernel= 2.4.19 Fabric OS Manual Publication Number: 53-1000240-01 2-389 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 424
successful execution of this command, a monitor number is displayed. The monitor number is provided for manipulation of these performance monitors. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 425
even when using commas. To add an end-to-end monitor to blade 1 port 2: switch:admin> perfaddeemonitor 1/2 "0x050200" "0x1182ef" End-to-End monitor number 0 added. See Also perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 426
numbers and user-defined aliases can be displayed with the perfShowFilterMonitor command. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported optional. The default alias is "IP Frame". Examples To add an IP monitor to a port: switch:admin> - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 427
. The maximum number of filters is eight per port including user-defined filters, read filters, write filters, read/write filters, SCSI frame monitor, and IP frame monitor. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 428
. The maximum number of filters is eight per port, including user-defined filters, read filters, write filters, read/write filters, SCSI frame monitor, and IP frame monitor. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 429
. The maximum number of filters is eight per port, including user-defined filters, read filters, write filters, read/write filters, SCSI frame monitor, and IP frame monitor. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 430
also displayed, if one was specified. All valid monitor numbers and user-defined aliases can be retrieved with the perfShowFilterMonitor command. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 431
in order to include spaces. This operand is optional. By default, the alias is an empty string. . To add a filter-based monitor for all Extended Link Service requests (R_CTL=0x22 and TYPE=0x01) to a port: switch:admin> perfaddusermonitor 1/4 "4, 0xff, 0x22; 12, 0xff, 0x01" User monitor #0 added - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 432
numbers and user-defined aliases can be retrieved with the perfShowFilterMonitor command. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported default alias is "SCSI_Write". Examples To add an SCSI Write command monitor to a port: switch: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 433
nonvolatile memory. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port from FLASH. See Also perfCfgRestore, perfCfgSave Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-399 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 434
This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC monitoring configuration information from nonvolatile memory: switch:admin> perfcfgrestore This will overwrite current Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 435
power cycles. The number of monitors saved to flash memory has the following limitations: • 16 EE monitors • 16 filter monitors • A total number of 512 monitors per a switch This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 436
31 is cleared. switch:admin> perfclearalpacrc 2/15 This will clear all ALPA CRC Counts on port 31 Do you want to continue? (yes, y, no, n) y Please wait ... All alpa CRC counts are cleared on port 31. See Also perfShowAlpaCrc 2-402 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 437
5 End-to-End monitor number 5 counters are cleared switch:admin> perfcleareemonitor 1/2 This will clear ALL EE monitors' counters on port 2, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfShowEEMonitor Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-403 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 438
-based monitor number 4 counters are cleared switch:admin> perfclearfiltermonitor 1/2 This will clear ALL filter-based monitors' counters on port 2, continue? (yes, y , no, n): [no] y See Also perfAddFilterMonitor, perfShowFilterMonitor 2-404 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 439
> perfdeleemonitor 7/2 5 End-to-End monitor number 5 deleted switch:admin> perfdeleemonitor 7/2 This will remove ALL EE monitors on port 2, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfShowEEMonitor Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-405 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 440
2/3 4 The specified filter-based monitor is deleted. switch:admin> perfdelfiltermonitor 2/3 This will remove ALL monitors on port 19, continue? (yes, y, no, n): [no] y See Also perfAddUserMonitor, perfShowFilterMonitor 2-406 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 441
monitoring: switch:admin> perfhelp based/ISL monitors Set overall mask for E-to-E monitors Get ALPA CRC count by port and ALPA Show user-defined end-to-end monitors Show filter-based monitors Show the current end-to-end mask See Also none Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 442
--class FLT 1/2 4 Filter-based monitor number 4 counters are cleared switch:admin> perfmonitorclear --class FLT 1/2 This will clear ALL filter-based monitors' counters on port 2, continue? (yes, y, no, y): [no] y 2-408 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 443
readability. perfMonitorClear 2 To clear statistics counters for an ISL monitor: switch:admin> perfmonitorclear --class ISL 1 This will clear ISL monitor on port , perfAddUserMonitor, perfAddWriteMonitor, perfMonitorShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-409 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 444
whole ISL Num_ports Number of ports in this ISL (one for a standalone ISL, more for trunks) Num_domains Total number of domains being monitored Domain_count 64-bit cumulative transmit counter for each individual domain 2-410 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 445
Brocade Advanced Performance Monitoring license. This command is not supported based), or ISL (interswitch link). These values are case-sensitive. slotnumber For bladed systems only, this operand specifies the slot number seconds: switch:admin> Manual Publication Number: 53-1000240-01 2-411 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 446
display cumulative filter monitor information on a port: switch:admin> perfmonitorshow --class FLT 2/5 There are 7 filter-based monitors defined on port 21. KEY ALIAS OWNER_APP WEB_TOOLS 192.168.169.40 0x000000000000033a 2-412 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 447
ISL monitor information on a port: switch:admin> perfmonitorshow --class ISL 1/1 Total transmit count for this ISL: 1462326 Number of destination domains monitored: 3 Number of ports in this ISL: , perfAddWriteMonitor Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-413 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 448
the AL_PA ID address field must be masked together, to support the FC4-48 blade. On this blade, one bit of the AL_PA ID address field is used with the Area ID address field to identify the upper 32 ports. For example, ports 128 and 256 may be addressed on Domain ID "dd" with Area ID - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 449
dd:aa:pp format. Examples To set the overall mask for end-to-end monitors on a port: switch:admin> perfsetporteemask 1/6 "00:00:00" "ff:ff:ff" "00:ff:ff" "ff:00:00 are deleted See Also perfAddEEMonitor, perfShowEEMonitor Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-415 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 450
devices on a specified port are displayed. CRC count is a 64-bit counter. The CRC count value is displayed in hexadecimal. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on the SilkWorm 200E, 4100, and 48000 platforms. This command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 451
Brocade Advanced Performance Monitoring license. This command is deprecated; use perfMonitorShow instead. This command is not supported bladed systems only, this operand specifies the slot number of every 6 seconds: switch:admin> perfshoweemonitor 4/5 Manual Publication Number: 53-1000240-01 2-417 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 452
cumulative information from EE monitors on a port: switch:admin> perfshoweemonitor 4/5 There are 7 end-to-end support counting CRC errors and therefore the CRC error counts will not be displayed for those platforms. perfAddEEMonitor 2-418 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 453
, relative to its slot for bladed systems. Use switchShow for a list of valid ports. interval Specify an interval, in seconds (5 or more). This operand is optional; if omitted, this command displays cummulative counts. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-419 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 454
display filter monitor information on a port: switch:admin> perfshowfiltermonitor 2/5 There are 7 filter-based monitors defined on port 21. KEY ALIAS OWNER_APP , perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor 2-420 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 455
default value of the EE mask is all fields set to "on." Note This command requires a Brocade Advanced number of the port on which the monitor is to be displayed, relative to its slot for bladed systems. Use switchShow for a list of valid ports. Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 456
is for readability. perfShowPortEEMask Examples To display the end-to-end mask on a port: switch:admin> perfshowporteemask 2/4 The EE mask onport 20 is set by application NONE TxSID Domain: , perfShowEEMonitor 2-422 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 457
Root Certificate... If run in secure mode, the following error message is displayed: switch:admin> pkicreate Warning !! Switch is in secure mode. Cannot create new Pki Objects. Exiting... See Also pkiRemove, pkiShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-423 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 458
switch private key, private key pass-phrase, CSR, root certificate, and switch switch:admin> pkiremove WARNING!!! Removing switch. If you want secure mode enabled, you will need to get the switch following error message is displayed: switch:admin> pkiremove This Switch is in secure mode. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 459
existence of PKI objects, such as switch private key, private key passphrase, CSR, root certificate, and switch certificate. Note The execution of this may be in place. Operands Examples none To view PKI objects: switch:admin> pkishow Passphrase : Exist Private Key : Exist CSR : Exist - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 460
ID of the policy. Valid values are 1 to 32, and ALL with the --show option. Optional --enc AES-256 Advanced encryption standard, 256-bit key. Specifies the authentication algorithm. The default is SHA default is 28800. 2-426 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 461
-1 Encryption: 3DES SA Life (seconds): 28800 To display all IKE policy settings: switch:admin> policy --show ike all IKE Policy 1 Authentication Algorithm: SHA-1 Encryption: AES Life (seconds): 28800 Operation Succeeded Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-427 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 462
(delete and re-create) a policy: switch:admin> policy ike --delete 10 This policy has been successfully deleted. switch:admin> policy ike --create 10 -enc aes Hellman Group: 1 SA Life (seconds): 28800 To delete a policy: switch:admin> policy ike --delete 10 The policy has been successfully deleted. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 463
to its slot for bladed systems. Use switchShow to list valid ports. To display the AL_PAs of a port: switch:user> portalpashow 4/14 AL_PA type AL_PA type 0xe2 public 0xe4 public AL_PA type See Also switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-429 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 464
full bandwidth (depending on the port configuration). If the number of Buffer Usage is less than the number of Needed Buffers, the port is operating in the buffer limited mode. Link Distance For L0 (not in long distance mode), the fixed distance displays based the switch. The supported distance - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 465
Note: Enter commands in lowercase only; mixed case is for readability. portBufferShow 2 Note The execution of this command is subject to Admin Domain restrictions that may be in place. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-431 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 466
Port Lx Max/Resv Buffer Needed Link Remaining Port Type Mode Buffers Usage Buffers Distance Buffers 16 - - 0 - - 17 E L1 - 54 54 50km 18 - - 0 - - 19 - - 0 - - 54 See Also portCfgLongDistance 2-432 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 467
portCamShow Displays port-based filter CAM utilization number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, information for all ports is displayed. Note Ports that support Manual Publication Number: 53-1000240-01 2-433 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 468
4 0 0 64 512 5 0 0 64 512 6 0 0 64 512 7 0 0 64 512 8 0 0 63 511 9 0 0 63 511 10 0 0 63 511 11 1 1 63 511 12 0 0 46 510 13 0 0 46 510 14 0 0 46 510 15 18 2 46 510 (output truncated) 2-434 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 469
: Enter commands in lowercase only; mixed case is for readability. portCamShow 2 To display the filter CAM utilization for a single port on a switch: switch:user> portcamshow 3/2 Area SID used DID used SID entries DID entries 34 3 1 350400 2b2200 2b1200 220400 SID Free, DID Free - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 470
together with -f (fastwrite) or -t (tape pipelining). -k timeout Specifies the keep alive timeout, in seconds. timeout values are 8 to 7,200; default is 10. If tape pipelining is enabled, minimum value supported is 80. 2-436 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 471
Manual Publication Number: 53-1000240-01 -key preshared-key Specifies the preshared-key to be used during IKE authentication. Its length can be up to a maximum length is 32 values are 1 to 8; default is 8.If tape pipelining is enabled, default value is calculated based on the mininum retransmit time - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 472
ipif iproute rscnsupr Specifies the maximum retransmissions for the existing tunnel. retransmissions values are 1 to 16; default is 8. If tape pipelining is enabled, default value is calculated based on the mininum retransmit time to ensure that tcp connection does not timeout before the host - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 473
values are 0 to 255. The default is 0. tunnel_id Specifies the FCIP port, the port can only be used as part of a mirror connection. Possible args for number of the port to be configured, relative to its slot for bladed systems. Use switchShow for a list of valid ports. To add an ARP entry: switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 474
a static IP route: switch:admin> portcfg iproute ge0 create 172.16.123.231. 255.255.0.0 192.168.255.25 1 Operation Succeeded To create an FCIP tunnel: switch:admin> portcfg fciptunnel ge0 create ..:OFF, ??:INVALID. LM:L0.5 2-440 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 475
for readability. portCfg 2 To configure a range of ports as RSCN supressed: switch:admin> portcfg rscnsupr 2/4-7 --enable switch:admin> portcfgshow [output from other slots suppressed] Ports of Slot 2 0 , switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-441 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 476
port to display, followed by a slash (/). portnumber Specify the number of the port to be returned to default values, relative to its slot for bladed systems. Use switchShow to list valid ports. To reset a port to factory defaults: switch:admin> portcfgdefault 1/3 To reset a GbE port to factory - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 477
command are persistent across switch reboots or power cycles. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 478
negotiated values are what the edge switch specifies in the ELP request. If the state is "Not OK", the R_A_TOV and E_D_TOV display "Not Applicable". By default, all EX_Ports are auto-ELP enabled ID. Valid values are 1-239. 2-444 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 479
legacy McDATA OS versions such as 5.0.2. To display the EX_Port configuration of port 2/0: switch:admin> portcfgexport 2/0 Port 2/0 info Admin: enabled State: OK Pid format: core(N) Operate mode: Brocade Native Edge Fabric ID: 16 Front Domain ID: 160 Front WWN: 50:06:06:9e:20:9f:ce - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 480
from the port. A value of 0 is the default port state. This operand is required. To configure a port as a locked G_Port: switch:admin> portcfggport 1/3, 1 See Also configure, portCfgLPort, portShow, switchShow 2-446 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 481
all fabric-wide parameters are consistent for every switch in the fabric. The complete list of fabric zoning will drop frames. This feature is persistent across reboots and power cycles. Use the portCfgShow command to view whether ISL R_RDY mode Manual Publication Number: 53-1000240-01 2-447 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 482
slash (/). portnumber Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. mode Specify 1 to enable ISL R_RDY mode. Specify 0 to disable ISL R_RDY mode. To enable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 1 ISL R_RDY - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 483
port to support a longdistance link up to 500 Km. The port can be used only as an E_Port. This configuration can be cleared but not set on VE/VEX_Ports. Changes made by this command are persistent across switch reboots or power cycles. Note This command requires a Brocade Extended Fabrics - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 484
long-distance link also can be configured to be part of a trunk group (see portCfgTrunkPort). Two or is not backward compatible with firmware versions that do not support it. Note If a switches and SilkWorm 48000 directors using FC4-16 and FC4-32 port blades, Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 485
command has the following operands: slotnumber Specifies the slot number, for bladed systems only. The slot number must be followed by a slash (/). portnumber Specifies a port number. Valid values for port number vary, depending on the switch type. Use switchShow to display a list of valid ports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 486
public L_Port. This operand is optional; if omitted; the default value of 0 is used. Private devices are supported only on SilkWorm 3250, 3850, and 3900 and directors with FC2-16 and FC2-16 blades. For other switches and blade types, option 1 is blocked. duplex_mode Specify 2 to configure the - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 487
. portCfgLPort 2 Examples To configure a port as a locked L_Port: switch:admin> portcfglport 4/15, 1 switch:admin> portcfgshow [output from other slots suppressed] Ports of Slot 4 Also configure, portShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-453 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 488
0 to 255 per port. The default value is 126 per port. The number of virtual port IDs per switch also can be configured. See configure for more information on configuring these values. Changes made by this command are persistent across switch reboots and power cycles. Use the portCfgShow command to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 489
NPIV capability .. .. .. ON EX Port where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 To disable NPIV functionality on a port: switch:admin> portcfgnpivport 1/3 0 See Also configure, portCfgDefault, portCfgShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-455 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 490
power cycles, switch reboots, and switch enables. By default bladed systems only, specify the slot number of the port to configure, followed by a slash (/). portnumber Specify a port number to configure, relative to its slot for bladed OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 491
across power cycles, switch reboots, and switch enables. By default, a bladed systems only, specify the slot number of the port to configure, followed by a slash (/). portnumber Specify a port number to configure, relative to its slot for bladed Manual Publication Number: 53-1000240-01 2-457 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 492
entries, IP routes, IP interfaces, FCIP tunnels, and mode. Information varies with the switch model and port type. The following configuration information displays: Speed Displays as 1G, 2G, the portCfgISLMode command. 2-458 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 493
portnumber Specifies the port number to display, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. This operand is optional; if omitted, this command displays information for all ports. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 494
only; mixed case is for readability. portCfgShow Examples To display the configuration settings for a switch: switch:user> portcfgshow Ports of Slot 2 0 1 2 3 4 5 6 7 8 ON ON ON ON ON ON Mirror Port Ports of Slot 2 16 17 18 19 20 21 22 23 24 25 26 27 Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 495
. portCfgShow 2 To display the configuration settings for a port: switch:user> portcfgshow 2/16 Area Number: 144 Speed Level: AUTO Trunk Port ON Long Distance OFF portCfgNPIVPort, portCfgSpeed, portCfgTrunkPort Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-461 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 496
is saved in nonvolatile memory and is persistent across switch reboots or power cycles. This configuration cannot be set on VE/ 2 Gbit/sec: switch:admin> portcfgspeed 2/3, 2 See Also portCfgShow, portShow, switchCfgSpeed 2-462 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 497
disrupted for a period of time. Note This command requires a Brocade ISL Trunking license. Note The execution of this command is subject to : switch:admin> portcfgtrunkport 1/3, 1 See Also portCfgShow, portShow, switchCfgTrunk, switchShow Fabric OS Command Reference Manual Publication Number: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 498
phantom domain to request a domain ID from the principal switch. The domain ID received becomes the subsequent preferred domain By default, all EX_Ports are auto-ELP enabled. The port ID format is applicable only when port_mode is "Brocade Native Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 499
fabric ID to 4: switch:admin> portcfgvexport 2/20 -a 1 -f 4 To disable fabric parameter negotiation on port 2/20 of an VEX_Port: switch:admin> portcfgvexport 2/20 -t 2 See Also portCfgEXPort, portDisable, portEnable, portShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 500
from an intelligent GbE port. Currently we do not support end-to-end path characterization if there exists an For bladed systems only, specifies the slot number. geport Specifies the port number of the GbE port on the blade. TCP port number for the listener end-point. This operand is optional. - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 501
specified, the maximum sized data buffer is used based on the outgoing IP interface MTU. The ipperf command with -i option or the default (30s). BW This is the payload. Note: There is limited support for black hole PMTU detection. If the Manual Publication Number: 53-1000240-01 2-467 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 502
Specifies the type of service in the ping request. The default is 0 and service_type must default is 64 bytes. The total size, including ICMP/IP headers (28 bytes without IP options) cannot be greater than the IP MTU configured on the Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 503
switch:admin> portcmd ipperf 4/ge0 -s 192.168.100.50 -d 192.168.100.40 -S ipperf to 192.168.100.40 from IP interface 192.168.100.50 on 4/0:3227 30s: BW:115.67MBps WBW(30s): 56.70MBps Loss(%):0.0 Delay(ms):2 PMTU:1500 See Also portCfg, portShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 504
5. vbs_lvl Specify the verbose level to be set for port modules; valid values are 1 to 5. To set debug level and verbose level of port modules: switch:admin> portdebug 3 4 See Also dbgShow 2-470 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 505
to its slot for bladed systems. Use switchShow to display a list of valid ports. To disable a port: switch:admin> portdisable 2/4 See Also portCfgPersistentDisable, portCfgPersistentEnable, portEnable, portShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 506
its slot for bladed systems. Use switchShow to display a list of valid ports. To enable a port: switch:admin> portenable 2/4 See Also portCfgPersistentDisable, portCfgPersistentEnable, portDisable, portShow, switchShow 2-472 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 507
with F_BSY Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-473 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 508
switch: switch 2 0 0 14: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 15: 0 0 0 0 0 0 0 0 0 0 0 2 0 0 16: 0 0 - 0 0 0 0 - 0 - - - - 17: 0 0 - 0 0 0 0 - 0 - - - - 18: 0 0 - 0 31: 0 0 - 0 0 0 0 - 0 - - - - - See Also portShow, portStatsShow 2-474 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 509
. Operands none Examples To display the port status for all ports in the switch: switch:user> portflagsshow Slot Port SNMP Physical Flags 1 0 Online In_Sync PRESENT ACTIVE ACTIVE E_PORT G_PORT LOGIN LED ACCEPT Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-475 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 510
2 Note: Enter commands in lowercase only; mixed case is for readability. portFlagsShow See Also portShow, switchShow 2-476 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 511
number of times to perform this test. The default switch are assumed. For more information, refer to the itemList command. To test port LEDs: switch:admin> portledtest -ports 1/1-1/5 passed. See Also itemList, switchDisable, switchEnable Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 512
command is subject to Admin Domain restrictions that may be in place. Operands Examples none To clear the port log: switch:admin> portlogclear switch:admin> portlogshow port log is empty See Also portLogDump, portLogShow 2-478 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 513
is subject to Admin Domain restrictions that may be in place. Operands Examples none To display the current port log configuration: switch:admin> portlogconfigshow max portlog entries = 8192 See Also portLogResize Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-479 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 514
The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples None. To display the port log facility: switch:admin> portlogdisable See Also portLogEnable 2-480 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 515
full explanation of the information displayed by this command, refer to the Fabric OS Administrator's Guide. number of lines to be displayed. Only the most recent count entries are displayed. This operand is optional. saved Specify a nonzero value to display the saved port log from the last switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 516
2 Note: Enter commands in lowercase only; mixed case is for readability. portLogDump See Also portLogClear, portLogShow, upTime 2-482 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 517
firmware, which can save up to 8,192 entries. Refer to portLogConfigShow to display the current port log size. Once the log is full, the newest log entries delete the oldest log entries. Port logs capture switch-to-device, device-to-switch, switch-to-switch, some device-to-device1, and control - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 518
The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples None. To enable the port log facility. switch:admin> portlogenable See Also portLogDisable 2-484 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 519
(1) or enabled (0). Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-485 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 520
13 stats 0 14 scn 0 15 pstate 0 16 reject 0 17 busy 0 18 ctin 0 19 0 30 write 0 31 err 0 32 frame 0 33 msRemQ 0 34 msRemR 48 cmd 0 49 event 0 50 msg 0 51 switch 0 52 ficonq 0 53 routing 0 2-486 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 521
Note: Enter commands in lowercase only; mixed case is for readability. portLogEventShow 2 See Also portLogTypeDisable, portLogTypeEnable Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-487 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 522
FLOGIs and EE (end-to-end) credit for PLOGIs. df_sz The default frame size for this login. cos Class of Services supported. This can be a combination of the following bits: 4 Class 2 is supported. 8 Class 3 is supported. Further information about each login is displayed after these columns - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 523
place. Operands Examples This command has the following operand: lvl Specify either 0 to clear or 1 to set the debug_pdisc_flag. To set the pdisc_flag: switch:admin> portlogpdisc 1 PDISC log setting = 1 See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-489 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 524
. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To enable the port log: switch:admin> portlogreset See Also none 2-490 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 525
The valid range of values is 32,768 to 65,536 for Silkworm 48000 Director and Silkworm 7500 Switch, and 8,192 to 16,384 for all others. To resize the portlog: switch:admin> portlogresize 12288 See Also portLogConfigShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-491 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 526
you to press Enter after each page of output. Port logs are circular log files in the switch firmware, which can save up to 32,768 entries. Refer to portLogConfigShow to display the current port log size. Once the log is full, the newest log entries delete the oldest log entries. Port logs capture - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 527
an exchange xerr Exchange error xstate Exchange state payload Frame payload Port Displays the port number that logged the event. Cmd Defined by the event. Displays a value defined by enable ports, 100 = disable ports Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-493 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 528
into two 16-bit fields: [A] a bit map indicating whether subsequent args are valid (0001 means argument 1 is valid, 0003 means arguments 1 and 2 are valid). [B] the CT-based service command code. are as follows: state 2-494 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 529
loop for QuickLoop looplet setup Restart loop for QuickLoop looplet re-initialization Start negotiation Negotiate master Wait for signal Negotiation follow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-495 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 530
a full explanation of the information displayed by this command, refer to the Fabric OS Administrator's Guide. number of lines to display. Only the most recent count entries are displayed. This operand is optional. saved Specify a nonzero value to display the saved port log from the last switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 531
has the following operands: portid Specify the port number of the port to display. To display a port log for port 14: switch:user> portlogshowport 14 time task event port cmd args portLogClear, portLogShow, upTime Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-497 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 532
to different log types can be obtained by running portLogEventShow. To disable event 2 from reporting to the port log: switch:admin> portlogtypedisable 2 See Also portLogDisable, portLogEventShow, portLogTypeEnable 2-498 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 533
The values corresponding to different log types can be obtained by running portLogEventShow. To enable event 2 to report to the port log: switch:admin> portlogtypeenable 2 See Also portLogEventShow, portLogTypeDisable Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-499 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 534
determine which components of the switch are faulty. Note The number Specify the slot number on which the diagnostic will operate. The ports specified will be relative to this slot number. The default is set to 0 and designed to operate 2-500 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 535
By default, all of the blade ports in the specified slot (--slot) are used. See itemList for more information. To run a functional test of a connection: switch:admin> portloopbacktest -ports 1/10-1/20 -nframes 1 -lb_mode 1 Running Port Loopback Test .... passed. Fabric OS Command Reference Manual - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 536
to the Fabric OS Message Reference for more information. See Also camTest, centralMemoryTest, cmemRetentionTest, cmiTest, crossPortTest, itemList, portRegTest, spinSilk, sramRetentionTest 2-502 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 537
all configured mirror ports on a switch use the portCfgShow command. Note The port mirroring feature is only supported on the following platforms: SilkWorm 4100, SilkWorm 4900, SilkWorm 7500, and SilkWorm 48000 Option 5. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-503 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 538
between two local switch ports: switch:admin> portmirror --delete 0x011400 0x012400 To delete a port mirror connection between a local switch port and a remote switch port: switch:admin> portmirror --delete 0x011400 0x240400 2-504 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 539
Note: Enter commands in lowercase only; mixed case is for readability. portMirror 2 To display port mirror connections: switch:admin> portmirror --show Number of mirror connection(s) configured: 2 Mirror_Port SID DID State 10/12 0x791800 0x791900 Defined 10/15 0x791a00 0x799300 Enabled - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 540
, the port names of all ports present are displayed. To name to a port Tape drive 8: switch:admin> portname 1/3, "Tape drive 8" switch:admin> portname 1/3 Tape drive 8 See Also configDefault, portCfgDefault, portShow 2-506 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 541
for all ports on the switch. Data displays in 8 or 16 columns, one column per interval, in seconds, between each sample. Default is one second. This operand is optional 43m 0 87m 0 272k 0 330 0 310m See Also portStatsShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-507 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 542
0x80000000 for a 32-bit register). The command is supported only on SilkWorm number. The default is 0. -ports itemlist Specify a list of blade ports to test. By default, all the blade default value is to disable this mode. 2-508 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 543
portRegTest 2 Examples To run a bit write/read test of the ASIC SRAMs and registers: switch:admin> portregtest -ports 1/0-1/15 Running Port Register Test .... Test Complete: "portregtest" Pass spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-509 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 544
number of a device (or set of looped devices) attached to the local switch. firmware. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 545
for readability. portRouteShow 2 Examples To display the routing tables for a port: switch:user> portrouteshow 4/15 port address ID: 0x02bf00 external unicast routing table: 1: , switchShow, topologyShow, uRouteShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-511 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 546
or geport will display information specific to the operand given. This will vary with the switch model and port type. See the OPERANDS section for details. portShow slot geport will display module (GBIC or other) present. 2-512 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 547
the edge fabric connected to the EX_Port. Authentication Type If the EX_Port is connected to an edge switch with no security, then the authentication is displayed as "None". If the edge switch is in secure mode, and Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-513 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 548
commands in lowercase only; mixed case is for readability. portShow assuming the DH-CHAP passwords are configured both on the router and the edge switch, the security type is displayed as "DH_CHAP". DH-CHAP is the only supported authentication type. DH Group If the EX_Port is connected to an edge - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 549
only, specify the slot number of the port to be configured, followed by a slash (/). [ge]port Specify the port number to be displayed, relative to its slot for bladed systems. See switchShow for a list of valid ports. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-515 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 550
0 Lr_out: 0 Ols_in: 0 Ols_out: 0 Port part of other ADs: Yes Frjt: 0 Fbsy: 0 To display IP interfaces on a GbE port: switch:admin> portshow ipif ge0 GE Port 0/ge0 Interface IP 168.255.27 255.255.255.0 1500 2-516 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 551
connection parameter information on an FCIP tunnel on a GbE port: switch:admin> portshow fciptunnel ge1 0 -params Port: ge1 Tunnel ID Configured Local WWN 10:00:00:05:1e:35:16:b9 Compression on Fastwrite off Tape Pipelining off Uncommitted Reference Manual Publication Number: 53-1000240-01 2-517 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 552
portShow To display the performance information on an FCIP tunnell: switch:admin> portshow fciptunnel ge1 0 -perf Port: ge1 Tunnel ID WWN Not Configured Local WWN 10:00:00:05:1e:35:16:b9 Compression on Fastwrite off Tape Pipelining off Uncommitted bandwidth, Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 553
03:04:60 Permanent, Resolved, To display IP routes on a GbE port: switch:admin> portshow iproute ge0 GE Port 0/ge0 IP Address Mask Gateway Metric Flags 0 Interface, 172.16.123.231 255.255.0.0 192.168.255.25 1 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-519 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 554
2 Note: Enter commands in lowercase only; mixed case is for readability. portShow To display iSCSI Port WWN and Sessions: switch:admin> portshow isci 2/ge0 GE Port 2/ge0 Port WWN Sessions 50:06:06:9e:40:09:a2:00 0 See Also authUtil, portCfg, portCfgLongDistance, portLoginShow, portName, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 555
only; mixed case is for readability. portStats64Show 2 portStats64Show Displays the 64-bit hardware statistics for a port. Synopsis portstats64show [slotnumber/]portnumber Byte rate (Bytes/sec). stat64_rateRxPeakByte Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-521 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 556
, specify the slot number of the port to be displayed, followed by a slash (/). portnumber Specify a port number to be displayed, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. 2-522 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 557
readability. portStats64Show 2 Examples To display the 64-bit hardware statistics for a port: switch:user> portstats64show 4/15 stat64_wtx 0 top_int : 4-byte words transmitted See Also portStatsClear, portStatsShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-523 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 558
a port number to be cleared, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. To clear the statistics for a port: switch:admin> portstatsclear 4/15 See Also portStats64Show, portStatsShow 2-524 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 559
display only with those platforms and ports. All statistics have a maximum 32-bit value of 4,294,967,295. stat_wtx stat_wrx stat_ftx stat_frx stat_c2_frx port specific). Other discards (platform and port specific). Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-525 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 560
displayed, followed by a slash (/). [ge]portnumber Specifies a port number to be configured, relative to its slot for bladed systems. Specify the optional ge option to display the GbE port hardware specified FCIP tunnel. 2-526 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 561
portStatsShow 2 Examples To display the basic set of statistics for a port: switch:admin> portstatsshow 13 stat_wtx 0 stat_wrx 0 stat_ftx 0 stat_frx 0 stat_c2_frx abort frames 0 GE overruns 0 GE Fifo overflow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-527 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 562
To display port statistics for IP address 192.168.255.10, slot 8, and GbE port 1: switch:admin> portstatsshow ip 8/ge1 192.168.255.10 ipaddr 192.168.255.10 IP address ip_out_octets Errors See Also portErrShow, portShow 2-528 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 563
reboots and power cycles. Note bladed systems. To swap area numbers between a pair of ports: switch:admin> portswap 1/3 2/5 portswap done See Also portDisable, portEnable, portShow, portSwapDisable, portSwapEnable, portSwapShow, switchShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 564
the portswap feature is persistent across reboots and power cycles. Note Enabling or disabling the portswap switch:admin> portswapdisable See Also portSwap, portDisable, portEnable, portShow, portSwapEnable, portSwapShow, switchShow 2-530 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 565
of the portswap feature is persistent across reboots and power cycles. Note Enabling or disabling the portswap feature switch:admin> portswapenable See Also portSwap, portDisable, portEnable, portShow, portSwapDisable, portSwapShow, switchShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 566
of the portswap feature, as well as port and area information for those ports whose area number id different from the default area number. The default area number of a port is same as its switch port number. Note The execution of this command is subject to Admin Domain restrictions that may be in - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 567
problems to a single replaceable element and isolate problems following port types are supported: • E_Ports • F_Ports (must support ELS Echo) • default, all the user ports in the switch are tested. Refer to itemList help pages for further details. Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 568
dataTypeShow command to view the types of pattern that are supported with portTest. dataTypeShow displays the pattern name, the pattern number to use with this option, and an example of this pattern. The default pattern type, if no pattern number is specified, is RANDOM (type=11) Specify the size - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 569
Specify a list of user ports to test. By default, all the user ports in the current slot will be further details. To display information from portTest: switch:admin> porttestshow 1 Port 1 : PASS PortType 0 ErrorCode: 0 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-535 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 570
2 Note: Enter commands in lowercase only; mixed case is for readability. portTestShow See Also crossPortTest, fportTest, loopPortTest, portLoopbackTest, portTest, spinFab, stopPortTest 2-536 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 571
ports of a switch. Output shows virtual port number (decimal), physical port number (decimal), online default zoning is enabled with "No Access" mode, "No Effective configuration: (No Access)" is displayed. Note This command requires a Brocade Reference Manual Publication Number: 53-1000240-01 2-537 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 572
blades can be powered up. The format of the display varies, depending on the switch model and the number of slots present. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none 2-538 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 573
power-off list order: switch:admin> powerofflistset Slot Current POL 10 1st 9 2nd 8 3rd 7 4th 4 5th 3 6th 2 7th 1 8th 1st slot to be powered off: (1..10) [10] 1 2nd slot to be powered , slotShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-539 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 574
5 will be powered off 6th Slot 4 will be powered off 7th Slot 3 will be powered off 8th Slot 2 will be powered off 9th Slot 1 will be powered off 10th See Also chassisShow, powerOffListSet, psShow, slotPowerOff, slotPowerOn, slotShow 2-540 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 575
23000000601 S1 Power Supply #2 is faulty DELTA DPS-1001AB-1E 23000000601 S1 Power Supply #3 is OK DELTA DPS-1001AB-1E 23000000601 S1 Power Supply #4 is absent IXD0111000088 IXD0111000162 IXD0111000120 See Also chassisShow, fanShow Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 576
of quiet mode, and then enable it: switch:admin> quietmode quietMode: On Usage: quietMode 0|1 0: to turn it off 1: to turn it on switch:admin> quietmode 0 Committing configuration...done Quiet Mode is now OFF See Also None 2-542 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 577
immediately reboot a CP in a director or an entire switch. The command line session is this switch is part of a fabric, reboot the switch so that the remaining switches reconfigure switch:admin> reboot Rebooting... See Also fastboot, switchReboot Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 578
Examples none To display a list of routing-related commands: switch:admin> routehelp bcastShow dlsShow fspfShow interfaceShow iodShow LSDbShow nbrStateShow topologyShow Also bcastShow, interfaceShow, uRouteShow 2-544 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 579
-F][-h ipaddress][-u user_name | -a][-p password] [-d remote_directory] To remove core name for the host name; default is anonymous. -p password Specify a password for the user name. -a Examples To list all core files in a CP: switch:admin> savecore -l /core_files/panic/core.873 /core_files - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 580
successfully! To FTP selected core file directories: switch:admin> savecore -h 192.168.204.188 -u jsmith -d core_files_here -p password -f /core_files/zoned/,/mnt/core_files/nsd/ / B/s Files transferred successfully! 2-546 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 581
2 To remove all core files using the savecore management utility: switch:admin> savecore following 1 directories contains core files: [ ]0: / brcd Password core_files/zoned/core.8323: Files transferred successfully! 1.12 kB 382.40 B/s Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 582
only; mixed case is for readability. saveCore To remove core files from a selected directory: switch:admin> savecore following 2 directories contains core files: [ ]0: /core_files/nsd [ ]1: / /zoned Done! See Also none 2-548 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 583
change arbitrarily. Operands none Examples To display the size of the active security database: switch:admin> secactivesize Size of security active data: 35 bytes (Max 262144 bytes) See Also secDefineSize, secGlobalShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-549 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 584
next authentication request. The configuration applies to a switch instance only. Note A Brocade Security license is required to run this command switch:admin> secauthsecret --show WWN DId Name 10:00:00:60:69:80:5b:e8 1 switch 2-550 Fabric OS Command Reference Manual Publication Number: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 585
requires authentication, deleting this database may cause switch to segment from the fabric. Do want to remove secret key database? (yes, y, no, n): [no] y Deleting secret key database... Done. switch:admin> See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-551 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 586
secCertUtil Manages third-party PKI-based certificates in the switch. Synopsis seccertutil Description Use this command to manage third-party certificates in the switch, as follows: • Generate existing CSR and all other 2-552 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 587
import [-config cacert] | [-config swcert [-enable https]] Import a certificate on to the switch. Use this for the following: • Download a certificate issued by a CA after sending the rsa public/private key pair Done. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-553 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 588
): filename Enter Login Name: login Enter Password: password Success: imported certificate [certificate file name switch:admin> seccertutil showcsr To display contents of a certificate: switch:admin> seccertutil show certificate file name 2-554 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 589
Note: Enter commands in lowercase only; mixed case is for readability. secCertUtil 2 See Also none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-555 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 590
arbitrarily. Operands none Examples To display the size of the defined security database: switch:admin> secdefinesize Size of security defined data: 35 bytes (Max 262144 bytes) See Also secActiveSize, secGlobalShow 2-556 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 591
.148 "nonfcs" Backup 10:00:00:60:69:00:12:53 2 Ready 192.168.100.147 "backup" Primary 10:00:00:60:69:22:32:83 3 Ready 192.168.100.135 "switch" Secured switches in the fabric: 3 See Also secPolicyDump, secPolicyShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-557 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 592
switch. Operands Examples none To enable a backup FCS switch to take over as the primary FCS switch: switch:admin> secfcsfailover This switch is about to become the Primary FCS switch. All transactions of the current Primary FCS switch OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 593
database This command is intended strictly for debugging purposes by technical support staff only. The information displayed might not be supported between releases and is subject to change arbitrarily. Operands none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-559 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 594
0x0 subt 0x8 dom 1 p 0 time 1882306 23:46:21 1024 Try to remove dom 1 switch 00:00:00:00:00:00:00:00 primary phasee 0 23:51:51 8199 ACA : flag 0x20e1 usec --------- LOG CACHE --------- See Also secActiveSize, secDefineSize 2-560 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 595
mode is enabled or disabled Sets the admin passwd for non-FCS switches Aborts changes to defined policy Activates all policy sets Adds members to password Resets temporary password Aborts current transaction Resets version stamp See Also none Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 596
Use this command to disable secure mode on all switches in the fabric. This command deletes both the password: Warning!!! About to disable security. ARE YOU SURE (yes, y, no, n): [no] y See Also secFabricShow, secModeEnable, secModeShow 2-562 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 597
is in secure mode and no FCS switches are present in the fabric, the command can be issued on any switch. This is used to recover a secure fabric that has no FCS switch. Only the --fcs option can be used in this case. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-563 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 598
expired while in non-secure mode cannot be used when secure mode is enabled. Passwords of such user accounts can be changed only after secure mode is disabled. Use is run on the switch specified as the primary FCS switch. 2-564 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 599
to enter FCS switch members and passwords. If the --currentpwd option is not used, the session becomes interactive and the user is prompted to enter new passwords for root, factory, admin, user, and non-FCS admin accounts. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 600
and Factory passwords are documented in a secure location. Recovery of a lost Root or Factory password will result in fabric downtime. Changing password for root New FCS switch root password: Re-type new password: (output truncated) 2-566 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 601
be set the same as FCS admin password. ARE YOU SURE (yes, y, no, n): [no] y Please enter current admin account password: Secure mode is enabled. See Also secFabricShow, secModeDisable, secModeShow, secPolicyShow, userRename Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-567 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 602
Version Stamp: 9182, Wed Mar 17 16:37:01 2004. POS Primary WWN DId swName. 1 Yes 10:00:00:60:69:00:00:5a 21 switch47. 2 No 12:00:00:60:60:03:23:5b 5 switch12. See Also secFabricShow, secModeDisable, secModeEnable 2-568 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 603
FCS switch admin password: Re-type new password: Login sessions with password changed will be terminated. Password for non-FCS admin account has been changed successfully. See Also passwd, secModeDisable, secModeEnable, secModeShow, secTempPasswdSet Fabric OS Command Reference Manual Publication - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 604
When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands Examples none To abort all changes that have not been saved to flash memory , secPolicyRemove, secPolicySave, secStatsShow 2-570 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 605
command activates the security policy set on all switches in the fabric and can be issued only from the primary FCS switch. In non-secure mode, if there are secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-571 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 606
Router. Note When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "name" Specify the name of an existing policy to not have to be 2-572 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 607
switch. The device is specified with a WWN string. The switch and port combination must be in the following format: can be specified using WWN, domain, or switch name. can be specified by port numbers OS Command Reference Manual Publication Number: 53-1000240-01 2-573 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 608
5 and all devices attached to those ports. [*] Selects all ports on the switch and devices currently attached to those ports. OPTIONS_POLICY members "NoNodeWWNZoning" is the only , secPolicyRemove, secPolicySave 2-574 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 609
When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "name" Specify the name of a The specified policy name must be capitalized. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-575 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 610
with a specific switch and port combination. An empty DCC_POLICY does not stop access to the switch. The device is specified with a WWN string. The switch and port combination must be in the following format: 2-576 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 611
is for readability. secPolicyCreate 2 Examples can be specified using WWN, domain, or switch name. can be specified by port numbers separated by commas and enclosed in either to access the fabric through Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-577 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 612
", "192.168.5.0" TELNET_POLICY has been created. primaryfcs:admin> See Also fddCfg, distribute, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow 2-578 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 613
Note When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "name" Specify the name of a security policy managed with this command. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-579 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 614
deleted, fabric-wide switch access through that method is unrestricted. Examples To delete an existing security policy: switch:admin> secpolicydelete "MS_POLICY secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow 2-580 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 615
databases. Note When secure mode is enabled, this command can be issued from all the FCS switches in the fabric. Operands This command has the following operands: "listtype" Specify which database SCC and DCC policies. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-581 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 616
.52.11 ACTIVE POLICY SET TELNET_POLICY IpAddr 192.155.52.0 See Also , secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyRemove, secPolicySave, secPolicyShow 2-582 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 617
the FCS list. Only one FCS can be moved at a time. The first FCS switch in the list that is also present in the fabric is the primary FCS. If no secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-583 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 618
When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands This command has the following operands: "name" Specify the name of an using IP address, WWN, domain, or switch name. 2-584 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 619
ports 3 and 9 and all devices attached to those ports. [1-3, 5] Selects ports 1 through 3 and 5 and all devices attached to those ports. [*] Selects all ports on the switch and devices currently attached to those ports. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-585 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 620
member that has a WWN of 12:24:45:10:0a:67:00:40 from MS policy: switch:admin> secpolicyremove "MS_POLICY", "12:24:45:10:0a:67:00:40" Member(s) have been removed , secPolicyDelete, secPolicyDump, secPolicySave, secStatsShow 2-586 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 621
fabric: switch:admin> secpolicysave secpolicysave command was completed successfully. See Also fddCfg, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secStatsShow Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 622
command displays the security policy database in effect on all the FCS switches in the fabric and can be issued from all FCS switches. In non-secure mode, this command displays the security policy SCC and DSS policies. 2-588 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 623
IpAddr 192.155.52.0 To display all security policies from defined databases: switch:admin> secpolicyshow "defined DEFINED POLICY SET FCS_POLICY Pos Primary WWN DId swName , secPolicyRemove, secPolicySave Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-589 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 624
0. This command can be issued to any switch. If issued on the primary FCS switch, this command can reset security statistics for any or all switches in the fabric. Operands This command has the are grouped together. 2-590 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 625
2 Examples "list" This operand is optional and the default is all statistics. If the list operand is specified, this switch:admin> secstatsreset "DCC_POLICY", "1;69" Reset DCC_POLICY statistic. See Also secFabricShow, secStatsShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 626
be issued to any switch. If issued on the primary FCS switch, this command can retrieve and display the security statistics for any or all switches in the fabric. • SLAP FAIL • SLAP_BAD_PKT • TS_OUT_SYNC • NO_FCS 2-592 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 627
is optional and the default value is the local switch. To display the MS_POLICY statistics on the local switch: switch:admin> secstatsshow "MS_POLICY" Value TELNET_POLICY 0 See Also secFabricShow, secStatsReset Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-593 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 628
. Passwords of all permanent accounts have been reset to fabric-wide values. Root and factory accounts on each Non FCS switch have been disabled. See Also secModeDisable, secModeEnable, secModeShow, secNonFCSPasswd, secTempPasswdSet 2-594 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 629
switch root password: Re-type new password: Login sessions with password changed will be terminated. Password successfully set on domain 2 for root See Also passwd, secModeDisable, secModeEnable, secModeShow, secNonFCSPasswd, secTempPasswdReset Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 630
application problems. This switch:admin> sectransabort Transaction has been aborted. See Also secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave, secStatsShow 2-596 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 631
0: switch:admin> secversionreset About to reset version stamp to 0. Are you sure (yes, y, no, n):[no] y done. Security Policy Version Stamp has been set to 0. See Also secFabricShow, secModeDisable, secModeEnable, secModeShow, secTransAbort Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 632
To view all sensor values: switch:admin> sensorshow sensor 1: (Temperature Power Supply ) is Ok sensor 11: (Power Supply ) is Absent sensor 12: (Power Supply ) is Ok sensor 13: (Power Supply ) is Absent See Also fanShow, tempShow 2-598 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 633
to the serial console. By default, no debug messages are displayed. time. The set of supported modules and their current debug switch:admin> setdbg NS 3 switch:admin> dbgshow NS Module NS, debug level = 3, verbose level = 0 See Also dbgShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 634
issue this command on the FR4-18i blade in a SilkWorm chassis; however, the command is not supported by the SilkWorm platform and does not ESD mode: switch:admin> setesdmode -show Esd Mode is 0 (Disabled). See Also spinSilk 2-600 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 635
current setting. This operand is optional. To enable the media mode: switch:admin> setgbicmode 1 GBIC mode is now 1 (Enabled). See Also crossPortTest, itemList, miniCycle, setMediaMode, setSfpMode, spinJitter, spinSilk Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-601 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 636
mode. -show Specify the -show operand to display the current setting. This operand is optional. To display the media mode: switch:admin> setmediamode -show Media mode is now 0 (disabled). See Also crossPortTest, itemList, miniCycle, setGbicMode, setSfpMode, spinJitter, spinSilk 2-602 Fabric - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 637
| [-d] Description Use this command to enable or disable modem dial-in to a CP on those systems that support modem dialin. When modem dial-in is enabled, you can log in to a CP through a modem, and the standby CP. . . . Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-603 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 638
0 a ! ! POWER SUPPLY 3 ! ! POWER SUPPLY 2 ! ! scale: 1/8" = 1" POWER SUPPLY 1 & 3 POWER SUPPLY 2 & 4 switch:admin> setmodem -d disabling modem, please wait, this can take a couple of minutes... modem disabled See Also none 2.015 2-604 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 639
is optional. To enable, disable, and then display the media mode: switch:admin> setsfpmode 0 SFP mode is now 0 (disabled). See Also crossPortTest, itemList, miniCycle, setGbicMode, setMediaMode, spinJitter, spinSilk Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-605 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 640
to isolate internal switch problems from SFP problems since the the FR4-18i blade in a SilkWorm chassis; however, the command is not supported by the SilkWorm switch:admin> setsplbmode -show Splb Mode is 0 (Disabled) See Also spinSilk 2-606 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 641
display of the debug message to the serial console. By default, no debug messages are displayed. Note The execution of switch:admin> setverbose NS 3 switch:admin> dbgshow NS Module NS, debug level = 0, verbose level = 3 See Also dbgShow, setDbg Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 642
module temperature, voltage, received optical power, transmitted optical power (longwave only), and laser number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, this command displays a summary of all SFPs in the switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 643
11: -Area 12: -Area 13: -Area 14: -Area 15: -Area 16: id (sw) Vendor: AGILENT (output truncated) Serial No: H1149T2 Serial No: H112TUD a Finisar "smart" SFP: switch:user> sfpshow 1/3 Identifier: 3 Power: 199.6 uWatts TX Power: 235.2 uWatts Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 644
information for GbE port 0 on a Silkworm 7500: switch:admin> sfpshow ge0 Identifier: 3 SFP Connector: 7 display detailed information for GbE port 0 on an FR4-18i router blade: CS48000:admin> sfpshow 10/ge0 Identifier: 3 SFP Connector: Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 645
only; mixed case is for readability. sfpShow 2 To display all SFP information: switch:user> sfpshow -all Port 0: Identifier: 3 SFP Connector: 7 LC Transceiver: (output truncated) See Also switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-611 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 646
is disabled by default. Because this command , persistent across reboots and power cycles. On dual control processor switch:admin> shellflowcontroldisable Disabling flowcontrol flow control is now disabled See Also shellFlowControlEnable 2-612 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 647
control is disabled by default. Because this command , persistent across reboots and power cycles. On dual control processor switch:admin> shellflowcontrolenable Enabling flowcontrol flow control is now enabled See Also shellFlowControlDisable Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 648
command is not supported on this platform as of FOS 5.1 - use slotPowerOff. Note The execution of this command is subject to Admin Domain restrictions that may be in place. See Also slotShow, slotPowerOff, bladeDisable 2-614 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 649
. This command is not supported on this platform as of FOS 5.1 - use slotPowerOn. Note The execution of this command is subject to Admin Domain restrictions that may be in place. See Also slotShow, slotPowerOn, bladeEnable Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-615 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 650
the slot number of the blade to be powered down. This operand is required. To power off blade unit 3: switch:admin> slotpoweroff 3 Slot 3 is being powered off See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow 2-616 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 651
following operand: slotnumber Specify the slot number of the blade to be powered on. This operand is required. To power on blade unit 3: switch:admin> slotpoweron 3 Powering on slot 3. See Also slotPowerOff slotShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-617 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 652
FC2-16 port blade 5 CP2 control processor blade 16 CP4 control processor blade 17 FC4-16 port blade 18 FC4-32 port blade 24 FR4-18i port blade 31 FR4-16IP port blade 36 FR4-48 port blade Status Displays the status of the blade: • VACANT The slot is empty. • INSERTED, NOT POWERED ON - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 653
Disabled) 6 CP BLADE 1 ENABLED 7 AP BLADE 24 LOADING 8 SW BLADE 2 DIAG RUNNING POST1 9 SW BLADE 2 INSERTED, NOT POWERED ON 10 UNKNOWN VACANT See Also bladeDisable, bladeEnable, chassisShow, slotPowerOff, slotPowerOn Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 654
verify the intended functional operation of the switch by sending SERDES BIST patterns from port The number of -passcnt count requested is reached. b. All ports are marked bad. Note This command is supported only default) 2-620 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 655
ports to test. By default, all the blade ports in the specified slot (--slot) is used. -passcnt count Specifies the number of test repetitions. By default, the test runs once. Refer to itemList for further details. To test the serial link of the following port path: switch:admin> sltest -ports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 656
switch. The configuration includes SNMPv1 and SNMPv3 configuration, access control list (ACL), MIB capability, and system group. It supports set, reset to default of community string should be in range of 2 to 16 characters. The default values for the community strings are: • Community 1: Secret - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 657
of three entries of role snmpadmin and three entries of role snmpuser are supported. Separate default passwords are provided for creation of authKey and privKey for each entry. Default set of passwords are published and default algorithm (MD5/SHA) is used to create initial set of auth keys. You - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 658
octets. For example, an ACL of 192.168.64.0 enables access by any hosts that start with the MIB and HA-MIB variables with an SNMP manager. The default value is yes. Specifying yes means the SNMP management application can receive SWTRAPS from the switch. The default Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 659
value is set as End User Premise. The contact information for this system (switch). The default value is set as Field Support. Refer to the definition of sysDescr, sysLocation and sysContact in system group of MIB-II. When enabled, the authentication trap (authenticationFailure) is transmitted to - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 660
in dot notation: [0.0.0.0] 10.32.225.1 Trap recipient Severity level default ***** sysDescr = Fibre Channel Switch sysLocation = End User Premise sysContact = Field Support authTraps = 0 (OFF) ***** Are you sure? (yes, y, no, n): [no] y 2-626 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 661
mixed case is for readability. snmpConfig 2 To change the SNMPv3 configuration: switch:admin> snmpconfig --set snmpv3 SNMPv3 user configuration: User (rw): [snmpadmin1] notation: [0.0.0.0] Committing configuration...done. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-627 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 662
Protocol (SNMPv1)" RFC1213, "Management information Base for Network Management of TCP/IP-based internets: MIBII" RFC2574, "User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)" 2-628 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 663
MIB and HA-MIB variables with an SNMP manager. The default value is yes. SW-TRAP Specifying yes means the SNMP management application can receive SWTRAPS from the switch. The default traps are turned off by default even if the corresponding trap Fabric OS MIB Reference Manual for more information - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 664
MIB traps: switch:admin> snmpmibcapset The SNMP Mib/Trap Capability has been set to support FE-MIB SW-MIB FA-MIB FICON-MIB HA-MIB n): [yes] fruHistoryTrap (yes, y, no, n): [no] See Also agtCfgDefault, agtCfgSet, agtCfgShow 2-630 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 665
management application can receive HA traps from the switch. The default value is 'yes'. Users can also turn on or off individual HA Traps. The individual HA Traps are fruStatusChanged, cpStatusChanged, and fruHistoryTrap. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-631 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 666
Note agtCfgDefault also resets the SNMP MIB and trap capability to default along with other SNMP agent configuration. the SNMP MIB capability: switch:admin> snmpmibcapshow FE-MIB: YES SW-MIB: YES FA-MIB: YES FICON-MIB: NO HA-MIB: YES SW Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 667
number of frames sent will be slightly larger, particularly at 2 Gbit/sec link speeds. -ports itemlist Specify a list of user ports to test. By default, all of the ISL ports in the current switch will be tested. Refer to itemList help pages for further details. -setfail mode Instruct spinFab - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 668
be useful with large values of -nmegs count. This mode is disabled by default. To test cascading ISL links: switch:admin> spinfab -ports 1/0 - 1/2 spinfab running... spinfab: Completed 11 , spinSilk, sramRetentionTest 2-634 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 669
. Note The command is supported only on SilkWorm 200E, default). For -lb_mode set to 0 or 1, the following speed modes are available to test the speed negotiation. 3 Set all even ports' speed for autonegotiate. Set all odd ports' speed for 1 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 670
2 Gbit/ sec. Specifies a list of user ports to test. By default, all the user ports in the specified slot (--slot) will be used. Refer to itemList for further details. To measure line-speed jitter: switch:admin> spinjitter -ports 1/0 - 1/2 Running SpinJitter Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 671
the Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, crossPortTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-637 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 672
operation of the switch, at the and mirrored the port on next blade, where applicable (0-16, 0-32, and so forth). An error (cable) or 1 (loopback plug, default) are selected, you must have the fails. The command is supported only on SilkWorm 200E, Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 673
can be used to determine which components of the switch are faulty. Note The execution of this command is default value is 10, so the number of frames sent will be at least 10 million. -lb_mode mode Specify the loopback point for the test. By default Manual Publication Number: 53-1000240-01 2-639 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 674
test. This parameter is used only for Bloom and Condor ASIC-based products, where it controls the speed at which each port is operated default, all of the user ports in the current switch are tested. Refer to itemList for further details. 2-640 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 675
ports 1/0 - 1/2 Running Spin Silk One moment please ...Ports Segmented (0) switchName: switch switchType: 10.1 switchState: Offline switchRole: Disabled switchDomain: 1 (unconfirmed) switchId: RXQ_FRAME_ERR Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-641 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 676
Fabric OS Message Reference for more information. See Also backport, camTest, centralMemoryTest, cmemRetentionTest, cmiTest, crossPortTest, itemList, portLoopbackTest, portRegTest, spinJitter, sramRetentionTest 2-642 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 677
on an operational switch. You must first disable the switch using the switchDisable command. The command is supported only on SilkWorm 200E the number of times to execute this test. The default value is 1. -ports itemlist Specify a list of blade ports to test. By default, all the blade ports - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 678
is for readability. sramRetentionTest Examples To run a data retention test: switch:admin> sramretentiontest 2 Running SRAM Retention Test ... passed. Diagnostics Following are , itemList, portLoopbackTest, spinSilk 2-644 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 679
the blade ports specified in bports clears; otherwise, the user ports specified in -uports clears. The default value is 0. To clear port and diagnostic statistics: switch:admin> statsclear -bports 1/10-1/62 -use_bports 1 See Also itemList Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 680
itemList for more information about selecting ports. This operand is optional. To run a statistics counter test on a switch: switch:admin> statstest -passcnt 1 -ports 1/0-15 Running Statistics Counter Test ....... passed. 2-646 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 681
-STSRCV DIAG-STSFRMCNT DIAG-STSWRDCNT DIAG-STSALPACNT Refer to the Fabric OS Message Reference for more information. See Also camTest, itemList Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-647 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 682
in the switch are tested. Refer to itemList help pages for further details. To stop the portTest command: switch:admin> stopporttest See Also crossPortTest, fportTest, loopPortTest, portLoopbackTest, portTest, portTestShow, spinFab 2-648 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 683
is enabled by default. Note The execution switch:admin> supportffdc --show First Failure Data Capture (FFDC) is disabled. To enable the FFDC events: switch:admin> supportffdc --enable First Failure Data Capture (FFDC) is enabled. See Also none Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 684
less than 48 characters. -t Sets time interval to check FTP server. -t has the following required operands: hours Checks the connectivity of FTP server at the indicated time interval (in hours). -R Clears FTP parameters. 2-650 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 685
: ftp parameters changed. To display a time interval to check the FTP server: switch:admin> supportftp -t 24 supportftp: ftp check period changed. See Also supportSave, supportShow, traceDump, traceFtp, traceTrig Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-651 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 686
the command is issued. If there are BP blades installed on the switch, it also retrieves a support file (as a .tar.gz file) from is optional; if omitted, anonymous FTP is used. Specifies the password for the FTP server. This operand is optional; if omitted, Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 687
/routing1-S6-200508280208-CHKRPM.ss: 10.04 kB 694.31 B/s Saving support information for switch:routing1, module:DIAGLOG... ...rtSave_files/routing1-S6-200508280207-DIAGLOG.ss: 195.34 kB (output truncated) 64.62 kB/s Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-653 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 688
-Zone_Log.ss: 27.71 kB 9.23 kB/s Saving support information for switch:swd76, module:Zone_Log... /tmp/supportSave_files/swd76-S6-200508280207-Zone_Log.ss: 48.16 kB 16.02 kB/s Saving support information for switch:routing1, module:RCS_Log... ...portSave_files/routing1-S6-200508280207-RCS_Log - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 689
switch information for debugging purposes. Synopsis supportshow [[slotnumber/]portnumber1-portnumber2] [lines] Description Use this command to display support per-port) • fabric (ENABLED by default) • fabricShow • islShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-655 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 690
• services (ENABLED by default) • fdmiCacheShow • fdmiShow • nsShow • nsAllShow • nscamShow • nscamShow -t • ns portshow • security (ENABLED by default) • authUtil • authUtil -dump -a • secFabricShow • secGlobalShow • secModeShow 2-656 Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 691
by default) • bootenv • sin • df • ifconfig • route • hostname • portlog (ENABLED by default) • portLogDump • system (ENABLED by default) • slotShow -d576 • emtraceshow • emtraceshow2 • emhsmtraceshow • systraceshow -d Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-657 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 692
lirr • ficonShow rlir • ficonShow rnid • ficonShow switchrnid • ficucmd dump -A • FC-FC Routing (DISABLED by default) • fcrProxyDevShow • fcrProxyConfig • fcrXlateConfig • fcrPhyDevShow • fcrRouteShow • fcrFabricShow 2-658 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 693
2 • fcrResourceShow • FCIP (DISABLED by default) • portShow fciptunnel ge$k all • portShow fciptunnel $1/ge$k all Note The execution of this command is subject to Admin Domain restrictions that may be in place. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-659 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 694
switch display in the per-port outputs. The slotnumber must be provided when specifying a range of ports on multi-bladed products. lines Specifies the number , supportShowCfgShow, traceDump, traceFtp, traceTrig 2-660 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 695
fabric Disables the fabric group commands services Disables the service group commands security Disables the switch:admin> supportshowcfgdisable os Config update Succeeded See Also supportShow, supportShowCfgEnable, supportShowCfgShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 696
fabric Enables the fabric group commands services Enables the service group commands security Enables the switch:admin> supportshowcfgenable os Config update Succeeded See Also supportShow, supportShowCfgDisable, supportShowCfgShow 2-662 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 697
fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend disabled filter disabled perfmon disabled ficon disabled See Also supportShow, supportShowCfgDisable, supportShowCfgEnable Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 698
beaconing pattern is shown. However, if diagnostic frame-based tests (portLoopbackTest, crossPortTest, and spinSilk) are executed, switch:admin> switchbeacon 1 To turn beaconing mode off: switch:admin> switchbeacon 0 See Also switchShow 2-664 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 699
Domain restrictions that may be in place. Operands Examples none To disable a switch persistently: switch:admin> switchcfgpersistentdisable See Also switchDisable, switchEnable, switchCfgPersistentEnable, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-665 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 700
configure the switch as persistently enabled: switch:admin> switchcfgpersistentenable 10 9 8 7 6 5 4 3 2 1 fabric: Principal switch fabric: Domain 1 See Also switchDisable, switchEnable, switchCfgPersistentDisable, switchShow 2-666 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 701
fixed at 2 Gbit/sec. 4 4-Gbit/sec mode. The port is fixed at 4 Gbit/sec. To set the speed level for all ports on a switch: switch:admin> switchcfgspeed 0 Committing configuration...done. See Also portCfgSpeed, portShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-667 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 702
on all the ports on this switch. This operand is required. To enable trunking on a switch: switch:admin> switchcfgtrunk 0 Committing configuration...done. See Also portCfgShow, portCfgTrunkPort, portShow, switchShow 2-668 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 703
to Admin Domain restrictions that may be in place. Operands Examples none To disable the switch: switch:admin> switchdisable See Also switchCfgPersistentDisable, switchCfgPersistentEnable, switchEnable, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-669 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 704
subject to Admin Domain restrictions that may be in place. Operands Examples none To enable a switch: switch:admin> switchenable See Also switchCfgPersistentDisable, switchCfgPersistentEnable, switchDisable, switchShow 2-670 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 705
this command displays the current switch name. To change a switch name to dilbert (note the change in the prompt text): switch:admin> switchname dilbert dilbert:admin> switchname dilbert See Also chassisShow, switchShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-671 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 706
Done. Starting all switch daemons...Done. Powering on slot 1...Done. Powering on slot 4...Done. Checking diagnostics...Done. setup FCIP IP: ifconfig fc0 ip=0.0.0.0, netmask=255.255.255.0 See Also switchShutdown, switchStart 2-672 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 707
continue to the maximum port of the platform. Index is to identify the port number relative to the switch. Index column is only displayed for slot based platforms. Slot Slot number; 1-4 and 7-10. Port Port number; 0-15, 0-31 or 0-47. Address The 24 bit Address Identifier. Address column is - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 708
in sync. Laser_Flt Module signaling a laser fault. Port_Flt Port marked faulty. Diag_Flt Port failed diagnostics. Lock_Ref Locking to the reference signal. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 709
OS Command Reference Manual Publication Number: 53-1000240 support ISCSI. FCIP Ports support FCIP. The comment field is blank, or displays: Disabled Port is disabled. Bypassed Port is bypassed (loop only). Loopback Port is in loopback mode. E_Port Fabric port; displays WWN and name of attached switch - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 710
number of ports on the switch. -iscsi Causes the switchShow command to display the number of iSCSI sessions associated with GbE ports in a switch. To display the port count: switch:admin> switchshow -portcount ports= 64 2-676 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 711
GE ports with iSCSI sessions: san116:user> switchshow -iscsi Ports of Slot 1 ge0 ge1 ge2 ge3 ge4 ge5 ge6 ge7 Sessions 0 0 0 0 0 0 0 0 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-677 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 712
for readability. switchShow To display switch information: top_4a3_a10:root> switchshow 8 15 035f00 id N2 Online F-Port 10:00:00:00:00:02:00:00 208 8 16 03d000 -- -- Offline [output truncated] 216 8 24 03d800 -- -- Online VE-Port 10:00 Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 713
switchShutdown Not supported on this platform. Synopsis switchshutdown Description This command is not supported on this platform as of FOS 5.1. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 714
2 Note: Enter commands in lowercase only; mixed case is for readability. switchStart switchStart Not supported on this platform as of Fabric OS 5.1. 2-680 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 715
Status Contributor DOWN Default MARGINAL Default PowerSupplies 2 1 Temperatures 2 1 Fans 2 1 WWN 0 1 CP 0 1 Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 Any single contributor can force the overall status of the switch to MARGINAL or DOWN - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 716
to MARGINAL status: (0..1) [1] MarginalPorts contributing to DOWN status: (0..64) [2] MarginalPorts contributing to MARGINAL status: (0..64) [1] (output truncated) See Also switchStatusPolicyShow, switchStatusShow 2-682 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 717
Values, and Status Contributor DOWN Default MARGINAL Default PowerSupplies 2 1 Temperatures 2 1 Fans 2 1 WWN 0 1 CP 0 1 Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 The policy parameters determine the number of failed or nonoperational units - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 718
: Down Marginal PowerSupplies 2 1 Temperatures 2 1 Fans 2 1 WWN 0 1 CP 0 1 Blade 0 1 Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 See Also switchStatusPolicySet, switchStatusShow 2-684 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 719
. Refer to switchStatusPolicyShow for details on the calculation of contributors and overall switch status. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands none Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-685 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 720
To display a switch health report: switch:user> switchstatusshow Switch Health Report Switch Name: switch IP address: 10.10.255.255 SwitchState: MARGINAL Duration: 00:06 Power supplies monitor Temperatures monitor Fans monitor WWN servers monitor Standby CP monitor Blades monitor Flash - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 721
is subject to Admin Domain restrictions that may be in place. Operands Examples none To view the uptime for the switch: switch:user> switchuptime 9:50pm up for 20 mins See Also switchReboot, switchShutdown, switchStart Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-687 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 722
the servers added through the command syslogdIpAdd. The default facility is LOG_LOCAL7. Note The execution of switch:admin> syslogdfacility -l 1 Syslog facility changed to LOG_LOCAL1 See Also syslogdIpAdd, syslogdIpRemove, syslogdIpShow 2-688 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 723
configured, the switch forwards all error log entries to the syslogd on the specified server(s). Up to six servers are supported. Note The switch:admin> syslogdipadd 192.168.1.60 See Also errShow, syslogdFacility, syslogdIpRemove, syslogdIpShow Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 724
is required. To remove the address 192.168.1.60 from the list of machines to which system messages are sent: switch:admin> syslogdipremove 192.168.1.60 See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpShow 2-690 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 725
of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To display all syslog daemon IP addresses: switch:admin> syslogdipshow syslog.IP.address.1: 192.168.1.60 syslog.IP.address.2: 192.168.1.88 syslog.IP.address.3: 192.168.2.77 See Also errShow - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 726
the command shuts down the active CP, standby CP, and any AP blades. After doing this, you need to manually power off the system. If you want to reboot the system, manually turn the power switch on. Note This command is not supported on the standby CP. Note The execution of this command is subject - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 727
: device is busy The system is halted flushing ide devices: hda Power down. ppc440gx System Halted For the FR4-18i AP blade, to perform a system shutdown from the standby CP: switch:admin> sysshutdown Shut down the whole system is not support from the standby CP For shut down the whole system please - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 728
is supported, this parameter is optional, but -unit is required for single FRU testing. -unit id Use to focus testing on a single FRU in the system. The id for a FRU type of BLADE correlates to the slot number of the FRU to be tested. 2-694 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 729
the fabric: switch:admin> systemverification -short systemverification: Setting parameters for short run. systemverification: burnin parameters. CURRENT - KEYWORD : DEFAULT 1 - diagSetBurnin, diagSetCycle Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-695 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 730
. For each sensor, this command displays the slot number (if applicable), the sensor state, and the temperature. The temperature readings are given in both Centigrade and Fahrenheit. Refer to the hardware reference manual for your switch to determine the normal temperature range. Note The execution - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 731
place. Operands Examples This command has the following operand: timeval Specify the number of minutes for the telnet timeout value. Valid values are 1 to current timeout value. To set the idle timeout to 10 minutes: switch:admin> timeout 10 IDLE Timeout Changed to 10 minutes The modified IDLE - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 732
part of the fabric, and to each of those domains, all possible paths from the local switch. • For each path cost, the associated output port on the local switch, the path cost, the number of hops from the local switch to the destination switch power of Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 733
5 Local Translate Domain 8 owned by port: 4 Domain: 6 Metric: 500 Name: switch Path Count: 4 Hops: Out Port: In Ports: Total Bandwidth: Bandwidth Demand: Flags: Also fcrXlateConfig, portRouteShow, uRouteShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-699 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 734
dump, or to display the dump status on the switch. Note If there is no parameter specified, this command defaults to traceDump -S. The default remote file name format is chassisname-S#-YYYYMMDDHHMMSS.dmp, in which # is the slot number (0 on nonbladed systems) and YYYYMMDDHHMMSS (year-month-day - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 735
hostip][-u username][-p password][-d remotedirectory][-f remotefile] Description Use this command to display, enable, or disable trace auto-FTP or to retrieve a trace dump file from the switch to the FTP site immediately. Note If there is no parameter specified, this command defaults to traceFtp - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 736
the auto-FTP feature: switch:admin> traceftp -e trace auto-FTP enabled To disable the auto-FTP feature: switch:admin> traceftp -d trace auto-FTP disabled See Also supportFtp, supportSave, supportShow, traceDump, traceTrig 2-702 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 737
on the track-changes commands: switch:admin> trackchangeshelp trackChangesSet Configure alert for login/logout/config update trackChangesShow Displays status of track changes See Also trackChangesSet, trackChangesShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-703 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 738
or 0 to disable the feature. The default (if no operand is specified) is to switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP-TRAP: YES See Also agtCfgSet, agtCfgShow, trackChangesHelp, trackChangesShow 2-704 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 739
output from the track-changes feature is dumped to the error log for the switch. Use the errDump command or errShow command to view the error log. Note The none To display the status of the track-changes feature: switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 740
. To debug a trunk connection: switch:admin> trunkdebug 43 44 Switch does not support trunking switch:admin> trunkdebug 62 63 port 62 and 63 are trunked together See Also portCfgTrunkPort, switchCfgTrunk, trunkShow 2-706 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 741
00:60:69:51:43:04 deskew 16 deskew 15 deskew 17 deskew 16 MASTER 3:24 -> 14 10:00:00:60:69:51:42:dd deskew 15 MASTER To display trunking information for a switch that is part of an FC Router backbone fabric interlinking Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-707 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 742
64-> 16 10:00:00:05:1e:37:12:13 65-> 19 10:00:00:05:1e:37:12:13 4 deskew 17 MASTER 4 deskew 16 4 deskew 16 4 deskew 16 4 deskew 17 4 deskew 17 4 deskew 15 4 deskew 16 switch:admin> switchshow 48 , switchCfgTrunk 2-708 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 743
set the clock server back to default. The NTP server used must support a full NTP client. Fabric OS v3 switch as teh clock server. This operand is optional. By default, this value is LOCL. If no operand is specified, the current value displays. Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 744
verify that the new IP address was saved: switch:admin> tsclockserver LOCL switch:admin> tsclockserver "123.123.123.123" Updating Clock Server configuration...done. switch:admin> tsclockserver 123.123.123.123 See Also date 2-710 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 745
to leave the time zone setup at the default. Time zone is used only in computing local time, which is used for error reporting and logging. An incorrect time zone setup does not affect the switch operation in any way. System services started during the switch boot reflect time-zone change only at - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 746
using interactive mode: switch:admin> tsTimeZone -- 48) Virgin Islands (UK) 15) Cuba 32) Netherlands Antilles 49) Virgin Islands (US) 16) Dominica 33) Nicaragua 17) Dominican Republic 34) Panama Enter number or control-D to quit ?45 2-712 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 747
Time 15) Mountain Time - south Idaho & east Oregon 16) Mountain Time - Navajo 17) Mountain Standard Time - Arizona switch admin> tstimezone --old 2 switch admin> tsttimezone Time Zone Hour Offset: 2 Time Zone Minute Offset: 0 See Also date Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 748
designated to operate on fixedport-count products. -passcnt count Specifies the number of times to perform this test. The default value is 1. -ports itemlist Specifies a list of blade ports to test. By default, all the blade ports in the specified slot are tested. Refer to the itemList command - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 749
a mini-switch. This is done by configuring all of the ports on the mini-switch in internal the same mini-switch. The frame through 5 for all ports present until either the number of frames (or -nmegs count) requested is reached type. Note This command is supported only on SilkWorm 200E,3250, 3850 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 750
slot number on which the diagnostic operates. The ports specified are relative to this slot number. The default is set . This parameter is used only for Bloom and Condor ASIC-based products, where For 1 Gbit/sec-only products, this option OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 751
stop on the first error. The default value is 0. Specify a list of user ports to test. By default, all of the user ports in the current switch are tested. This option can be used , portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-717 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 752
system load averages for the past 1, 5, and 15 minutes. For up and powered-on times less than 60 seconds, the time is displayed in seconds. For Operands Examples none To display the length of time the system has been operational: switch:admin> uptime 12:03am up 4:56, 3 users, load average: 1.17, - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 753
configuration is not supported on SilkWorm directors set to chassis switch:admin> urouteconfig 1 2 5 done. switch:admin> urouteshow 1/1 2 Local Domain ID: 1 In Port Domain Out Port Metric Hops Flags Next (Dom, Port) 1 2 5 500 1 S 2,5 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 754
2 Note: Enter commands in lowercase only; mixed case is for readability. uRouteConfig See Also configShow, interfaceShow, uRouteRemove, uRouteShow 2-720 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 755
domain of the static route to remove. To remove a static route for all traffic coming in from port 1 and addressed to domain 2: switch:admin> urouteremove 1 2 done. See Also configShow, dlsShow, uRouteConfig, uRouteShow Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-721 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 756
to be displayed, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. This operand is optional; if omitted, the command displays routing information for all input ports in the switch. 2-722 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 757
to domain 4 only: switch:admin> urouteshow 1/11, 4 Local Domain ID: 3 In Port Domain Out Port Metric Hops Flags Next (Dom, Port) 11 4 16 500 1 D 4,16 See Also portRouteShow, topologyShow, uRouteConfig, uRouteRemove Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 758
default Admin, SwitchAdmin or User account. When the userConfig command completes, account information is saved persistently. In a platform supporting multiple switch domains, account information is saved only to the switch 2-724 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 759
prompts for an initial password. There can be a maximum of 256 customer created accounts. -- existing account named username from the switch. This action does not take any deletion: You cannot delete any default account. You cannot delete your Manual Publication Number: 53-1000240-01 2-725 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 760
option expires the current password, forcing a password change the next time Domain of any default account. You cannot switch-local user database only, regardless of whether the switch is configured to use RADIUS authentication or not. 2-726 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 761
Date: Not Applicable Locked: No AD membership: 0 Home AD: 0 To change account attributes: switch:admin> userconfig --change joe -e no Broadcast message from root Sat Apr 2 03:03:32 2005... Security Policy, Password or Account Attribute Change: joe will be logged out Attribute for account joe has - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 762
the admin-level login name to the Brocade-specific default of admin and the user-level login name to the Brocade-specific default of user before enabling security; otherwise, the switch is not allowed in the secure fabric. Note This command is not supported on all platforms. Note The execution of - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 763
firmware version information in a switch: switch:admin> version Kernel: 2.4.19 Fabric OS: v5.2.0v5.2.0_pit_060911_0600 Made on: Mon Sep 11 18:55:09 2006 Flash: Mon Sep 11 19:26:15 2006 BootProm: 4.5.3 See Also firmwareDownload, reboot Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 764
10:00:ff:ff:ff:80:02:3c The switch must be rebooted for the new WWN to take effect. Reboot now? (yes, y, no, n): [yes] y Rebooting switch 0 ... [system reboots] switch:root> wwn 10:00:ff:ff:ff:80:02:3c See Also switchShow 2-730 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 765
Specifies a zone object. A zone object can be a zone member, zone alias or a zone. --validate [-f | -m mode] ["zone_object"] • Lists all zone members that are not part of the current zone enforcement table. The reason for not being in the current enforcement table could be one of the Fabric OS - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 766
the assumed default mode switch:admin> zone --copy AD0.backup_zn To copy backup_zn zone from the root zone database (AD0) to the current Admin Domain, with Admin Domain member list filtering: switch:admin> zone --copy -f AD0.backup_zn 2-732 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 767
in the persistent storage: switch:admin> zone --validate -m 1 To validate the zone object zone_test in the zone database in the current transaction buffer: switch:admin> zone --validate -m 0 zone_test See Also zoneHelp Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-733 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 768
Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch of the following: • A switch domain and port area number pair; for example, "2, 20". View the area numbers for ports using the switchShow Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 769
Spaces are ignored. Zone names are limited to 64 characters. The zone member list must have at command. Note This command requires a Brocade Advanced Zoning license. Use this command switch controls data transfer to a port. Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-735 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 770
for any other zone object. Zone names are limited to 64 characters. "member" List of members to be included in following: • A switch domain and port area number pair: for example, "2, 20". View the area numbers for ports using Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 771
a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. "Blue_zone": switch:admin> zonedelete "Blue_zone" See Also zoneAdd, zoneCreate, zoneRemove, zoneShow Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 772
that may be in place. Operands Examples none To display zone command help information: switch:admin> zonehelp aliAdd aliCreate aliDelete aliRemove aliShow Add a member to a zone alias Create transaction See Also none 2-738 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 773
", "UK_cfg" switch:admin> cfgshow "*" cfg: UK_cfg Red_zone; White_zone; Blue_zone cfg: USA_cfg Red_zone; White_zone; Blue_zone See Also cfgAdd, cfgClear, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow, zoneObjectRename Fabric OS Command Reference Manual Publication Number: 53 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 774
This command requires a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands Examples This cfgSave, cfgShow, zoneObjectCopy, zoneObjectRename 2-740 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 775
:admin> zoneobjectrename "USA_cfg", "UK_cfg" switch:admin> cfgshow "*" cfg: UK_cfg Red_zone; White_zone; Blue_zone See Also cfgAdd, cfgClear, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow, zoneObjectCopy Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-741 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 776
a Brocade Advanced Zoning license. When secure mode is enabled, this command can be issued only from the primary FCS switch. Operands switch:admin> zoneremove "Blue_zone", "array2" See Also zoneAdd, zoneCreate, zoneDelete, zoneShow 2-742 Fabric OS Command Reference Manual Publication Number: - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 777
. The default value is 0. This operand is optional. To display all zones beginning with the letters "A" through "C": switch:admin> zoneshow "[A-C]*" zone: Blue_zone 1,1; array1; 1,2; array2 See Also zoneAdd, zoneCreate, zoneDelete, zoneRemove Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 778
2 Note: Enter commands in lowercase only; mixed case is for readability. zoneShow 2-744 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 779
to the Fabric OS Administrator's Guide. Advanced Zoning Commands The following commands are available with the purchase of a Brocade Advanced Zoning license key. Deletes a zone. zoneRemove Removes a member from a zone. Fabric OS Command Reference Manual 3-1 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 780
transaction. defZone Activates or deactivates a default zone configuration, or displays the current commands are available with the purchase of a Brocade Advanced Zoning license. Table 3-2 QuickLoop Fabric information. 3-2 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 781
supported on Fabric OS v4.x or v5.x. Extended Fabrics Command The following command is available with the purchase of a Brocade switch default values. Displays the thresholds monitored by Fabric Watch. Displays sensor readings. Fabric OS Command Reference Manual 3-3 Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 782
Administrator's Guide. Table 3-5 Brocade Trunking Commands Command Description portCfgTrunkPort Configures a port for trunking. switchCfgTrunk Configures a switch for Adds a SCSI Read and Write monitor to a port. 3-4 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 783
-to-end (EE) monitors. Displays the AL_PA CRC count by port or by AL_PA. Displays user-defined end-to-end monitors on a port. Displays filter-based monitors for a port. Displays the current end-to-end mask of a port. Fabric OS Command Reference Manual 3-5 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 784
Guide. Table 3-7 Brocade party PKI-based certificates in the switch. Displays the switch to take over as primary FCS switch Sets the admin password for non-FCS switches. Aborts all defined policy set to all switches in the fabric. Adds policy to flash memory on all switches in the fabric. Displays an - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 785
secTempPasswdReset Resets a password on a remote switch. secTempPasswdSet secTransAbort secVersionReset Sets a temporary password on a remote switch. Aborts current security transaction. Resets the version stamp to 0. Fabric OS Command Reference Manual 3-7 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 786
3 3-8 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 787
the primary FCS switch. cfgSave Must be run from the primary FCS switch. cfgShow Can be run on all FCS switches. cfgSize Must be run from the primary FCS switch. cfgTransAbort Must be run from the primary FCS switch. Fabric OS Command Reference Manual 4-1 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 788
secPolicyRemove Must be run from the primary FCS switch. secPolicySave Must be run from the primary FCS switch. secPolicyShow Can be run on all FCS switches. secTempPasswdReset Must be run from the primary FCS switch. 4-2 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 789
Must be run from the primary FCS switch. zoneObjectExpunge Must be run from the primary FCS switch. zoneObjectRename Must be run from the primary FCS switch. zoneRemove Must be run from the primary FCS switch. Fabric OS Command Reference Manual 4-3 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 790
4 4-4 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 791
CP in a SilkWorm 24000 or 48000 director. The full set of commands for your user role are available to the active CP. Commands Supported on the Standby CP The following commands are supported when logged into the standby CP. Table 5-1 Commands Supported on the Standby CP Command Description - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 792
Commands Supported on support information for RASLOG, TRACE, and supportShow. switchName Displays this switch's name. tsClockServer Displays time zone. upTime Displays how long switch has been up. version Displays firmware version. 5-2 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 793
on page 6-4 supportShow Control Commands The supportShow command is used to display support information by executing groups of preselected Fabric OS and Linux commands. The commands from displaying under supportShow. Fabric OS Command Reference Manual 6-1 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 794
fablogdump fabricShow islShow trunkShow topologyShow fabStateShow fabSwitchShow fabStatsShow fabPortShow fspfShow fcplogshow zone-stateshow portzoneshow portCamShow cfgSize cfgShow rcssmshow rcsinfoshow rcsregistryshow 6-2 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 795
) Command Group Fabric OS v3.2.0 Fabric OS v4.x/v5.x services nsShow nsAllShow nscamShow fdmiCacheShow ficonDbg dump rnid ficonDbg log ficonShow ilir portlog portLogDump (no parameters) portLogDump portLogDump 0, 1 Fabric OS Command Reference Manual 6-3 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 796
are intended for support use only. These commands are not intended for end-users. Proc Entry Information Displayed The os command group prints a number of proc entries. Table 6-2 displays example proc entry information. 6-4 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 797
: 1.69 (pvr 4011 0145) bogomips : 199.47 machine : Brocade Silkworm plb bus clock : 100MHz pci bus clock : 33MHz /proc/ 136 pts 162 raw 245 swd 246 ham 247 fc 248 fc-switch 249 fabsys 250 fss_kt 251 fss_data 252 fss_mgmt 253 portlog 254 platform Block Manual Publication Number: 53-1000240-01 6 6-5 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 798
proc rw 0 0 none /dev/pts devpts rw 0 0 none /tmp ramfs rw 0 0 /dev/hda2 /mnt xfs rw,noatime 0 0 /diag /diag dfs rw 0 0 6-6 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 799
device: Brocade Communications Systems, Inc. Bloom switch (rev 0). IRQ 26. ---- /proc/slabinfo /proc/slabinfo slabinfo - version: 1.1 kmem_cache 74 102 112 3 3 1 ip_mrt_cache 0 0 96 0 0 1 tcp_tw_bucket 2 40 96 1 1 1 tcp_bind_bucket 5 113 32 1 1 1 tcp_open_request 0 59 64 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 800
processes 17684 /proc/tty/drivers /proc/tty/drivers serial /dev/cua 5 64-65 serial:callout serial /dev/ttyS 4 64-65 serial pty_slave /dev/pts 136 0-255 pty:slave pty_master /dev/ptm 128 #1 Wed Mar 26 00:04:35 PST 2003 6-8 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 801
/Standby availability: on chassis-based systems, check that the such as whether the command is supported on the platform for which available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin authUtil NN N N Manual A-1 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 802
= observe-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin aptPolicy NN N N N N N auditCfg OO O O O O OM chassisName O OM OM N OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 803
-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin chassisShow O OM OM N OM O OM chipRegShow O OM N OM O OM distribute NN N N OM N OM Fabric OS Command Reference Manual A-3 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 804
OM = observe-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin dlsReset OO O N OM O OM dlsSet OO O N OM O O OM fazoneShow OO O OM OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 805
modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin fcipChipTest O OM OM N OM O OM fciphelp OO OM OM N OM O OM ficonHelp OO O O O O O Fabric OS Command Reference Manual A-5 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 806
observe-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin ficonShow O OM OM N OM O OM filterTest O OM N OM O OM haEnable O O OM N OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 807
observe-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin haFailover O O OM N OM O OM haShow O O O O O licenseIdShow O OM OM O OM O OM Fabric OS Command Reference Manual A-7 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 808
, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin licenseport O OM OM N OM OM OM licenseRemove O O OM O OM O OM nsZoneMember O O OM O OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 809
N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin openSource O OM OM O OM O OM passwd OM pkiCreate OO O N O O OM pkiRemove OO O N O O OM Fabric OS Command Reference Manual A-9 Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 810
observe-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin pkiShow OO O N O O OM policy O OM OM OM O OM portLogDumpPort O OM OM O OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 811
-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin portLogEnable O OM OM O OM O OM portLogEventShow O OM OM psShow O OM OM N OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 A-11 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 812
-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin quietMode O OM OM N OM OM OM reboot O OM N OM O OM secTempPasswdReset ON O N OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 813
, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin secTempPasswdSet ON O N OM O OM secTransAbort ON OM O OM supportShow O OM OM O OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 A-13 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 814
N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin supportShowCfgDisable O OM OM O OM O OM OM O OM O OM trunkDebug O OM OM N OM OM OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 815
= observe-modify, N = none/not available) Command Name User Oper Switch Zone Fabric Basic Admin ator Admin Admin Admin Switch Admin trunkShow O OM OM N OM OM OM tsClockServer O OM OM zoneShow OO O OM OM O OM Fabric OS Command Reference Manual Publication Number: 53-1000240-01 A-15 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 816
A A-16 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 817
, 2-640, 2-667, 2674, 2-716 A AAA services 2-2, 2-3 access levels 1-1 account lockout policy 2-381 2-286, 2-292, 2-481 Admin Domain restrictions 2-2, 2-5, 2-16, 2-19, 2-22, 2-30, 2-32, 2-33, 2-35, 2-37, 2-39, 2-40, 2- 2-58, 2-59, 2-60, 2-61, 2-62, 2-63, 2-64, 2-65, 2-68, 2-70, 2-71, 2-84, 2-112, 2- - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 818
, 2-635, 2643, 2-645, 2-646, 2-664, 2-669, 2-694, 2-695, 2-714, 2-716 DID used 2-433, 2-434, 2-435 DLS, see dynamic load sharing DMA test 2-190 domain name service 2-140 dual-domain systems 2-16, 2-19, 2-75, 2-228, 2-297, Index-2 Fabric OS Command Reference Manual Publication Number: 53-1000240-01 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 819
-16 port blade 2-450, 2-452, 2-618 FC4-16 port blade 2-450, 2-618 FC4-32 port blade MIB 2-624, 2-628, 2-630, 2-631, 2-632 FICON-TRAP 2-624, 2-628, 2-631 field replaceable unit, see FRU filter-based monitor 2-397, 2-404, 2-406, 2-407, 2408, 2-412 firmware download 2-227, 2-228, 2-232, 2-233 firmware - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 820
652, 2-653, 2-654, 2-701, 2-702 full-duplex 2-282, 2-452 G G_Port 2-430, 2- 2-294, 2-544, 2-633 Inter-Switch Link 2-410 interswitch link 2-30, high availability HA-MIB 2-624, 2- 64, 2-65, 2-68, 2-70, 2-71, 2-84, 2-112, 2-114, Index-4 Fabric OS Command Reference Manual Publication Number: 53-1000240 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 821
SAN 2-334 2-91, 2-97, 2-98 memory usage 2-339 MIB 2-16, 2-17, 2-18, 2-19, 2-20, 2- 2-208 NTP Server address 2-709 P password 2-74, 2-88, 2-94, 2-230 48, 2-52, 2-107, 2-119, 2-120, 2-127, 2-128, 2-129, 2-133, 2-170, 2-600, 2-618, 2666, 2-670 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 822
power-on self-test, see POST primary FCS 2-17, 2-20, 2-23, 2-25, 2-26, 2-27, 2-28, 2-29, 2-57, 2-58, 2-59, 2-60, 2-61, 2-62, 2-63, 2-64 link status 2-189 reboot 2-48, 2-72, 2-74, 256, 2-262, 2-332, 2-475, 2-605, 2-606, 2-608, 2-609, 2-611 Index-6 Fabric OS Command Reference Manual Publication Number - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 823
switch name 2-87, 2-145, 2-148, 2-195, 2-256, 2-316, 2-557, 2-564, 2-566, 2-573, 2-576, 2-577, 2584, 2-585, 2-671, 2-686 switch speed 2-667 SW-TRAP 2-624, 2-628, 2-629, 2-630, 2-631, 2-632 syslog 2-144, 2-688, 2-689, 2-690, 2-691 system services Manual Publication Number: 53-1000240-01 Index-7 - HP StorageWorks 4/64 | Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 824
2-25, 2-26, 2-27, 2-28, 2-56, 2-57, 2-58, 259, 2-60, 2-61, 2-62, 2-63, 2-64, 2-65, 2-68, 270, 2-71, 2-72, 2-74, 2-84, 2-87, 2-100, 2-112, 2-113, 2-114, 739, 2-740, 2-741, 2-742, 2-743, 3-1, 32 Advanced Zoning commands 3-1 Index-8 Fabric OS Command Reference Manual Publication Number: 53-1000240-01
Publication Number: 53-1000240-01
Publication Date:
09/29/2006
Fabric OS
Command Reference Manual
Supporting Fabric OS v5.2.0