HP StorageWorks 4/64 Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 433
perfCfgClear
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 433 highlights
Note: Enter commands in lowercase only; mixed case is for readability. perfCfgClear 2 perfCfgClear Clears the previously saved performance monitoring configuration settings from nonvolatile memory. Synopsis perfcfgclear Description Use this command to clear the previously saved end-to-end and filter configuration settings of performance monitoring from nonvolatile memory. Note This command requires a Brocade Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands Examples none To clear the performance monitoring information from nonvolatile memory: switch:admin> perfcfgclear This will clear Performance Monitoring settings in FLASH. The RAM settings won't change. Do you want to continue? (yes, y, no, n): [no] y Please wait ... Performance Monitoring configuration cleared from FLASH. See Also perfCfgRestore, perfCfgSave Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-399