HP StorageWorks 4/64 Brocade Fabric OS Command Reference Manual (53-1000240-01 - Page 141
crossPortTest, Examples, See Also, spd_mode, lb_mode, norestore, ports
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 141 highlights
Note: Enter commands in lowercase only; mixed case is for readability. crossPortTest 2 Examples -spd_mode mode -norestore mode -ports itemlist 3 Silkscreen loopback 5 Internal (parallel) loopback Specify the speed mode for the test. This parameter is used only for Bloom and Condor ASIC-based products, for which it controls the speed at which each port is operated. For 1 Gbit/sec-only products it is ignored. The exact operation of each mode 5 through 8 depends upon the loopback mode selected. When speed modes 5 through 8 are used with cables, they must be connected even to odd or the test will fail. Valid values are: 0 Run test at both 1 Gbit/sec, 2 Gbit/sec, and 4 Gbit/sec (default). 1 Set all port speeds to 1 Gbit/sec. 2 Set all port speeds to 2 Gbit/sec. 4 Set all port speeds to 4 Gbit/sec. For -lb_mode set to 0 or 1, the following speed modes is available to test the speed negotiation: 5 Set all even ports speed to AN; set all odd ports speed to 1 Gbit/sec. 6 Set all even ports speed to AN; set all odd ports speed to 2 Gbit/sec. 7 Set all odd ports speed to AN; set all even ports speed to 1 Gbit/sec. 8 Set all odd ports speed to AN; set all even ports speed to 2 Gbit/sec. For -lb_mode set to 2 or 3, the following speed modes are available to test FIFO underrun: 5,7 Set all even ports speed to 2 Gbit/sec; set all odd ports speed to 1 Gbit/ sec. 6,8 Set all even ports speed to 1 Gbit/sec; set all odd ports speed to 2 Gbit/ sec. Specify 1 to force the test to skip part of the POST cleanup normally performed. This might be helpful during debug. This parameter should normally be left at the default value of 0. Specify a list of user ports to test. By default, all the user ports in the current switch will be used. Refer to itemList for more information. To run a functional test of all the ports on a switch: switch:admin> crossporttest -ports 1/0-1/15 Running crossporttest Ports Segmented (0) Executing test ... Test Complete: crossporttest Pass 10 of 10 Duration 0 hr, 0 min & 8 sec (0:0:8:725). passed. See Also camTest, centralMemoryTest, cmemRetentionTest, cmiTest, itemList, portLoopbackTest, portRegTest, spinSilk, sramRetentionTest Fabric OS Command Reference Manual Publication Number: 53-1000240-01 2-107