Input/Output Interfaces 5.6.4 Parallel Interface Connector Figure 5-5 and Table 5-5 show the connector and pinout of the parallel interface connector. Note that some signals are redefined depending on the port's operational mode. Figure 5-5. DB-25 Parallel Interface Connector (as viewed from rear of chassis) Table 5-5. DB-25 Parallel Connector Pinout Pin Signal Function Pin Signal Function 1 STB2 D0 Strobe / Write [1] Data 0 14 LF15 ERR- Line Feed [2] Error [3] 3 D1 Data 1 16 INIT- Initialize Paper [4] 4 D2 5 D3 Data 2 Data 3 17 SLCTIN- Select In / Address. Strobe [1] 18 GND Ground 6 D4 Data 4 19 GND Ground 7 D5 8 D6 Data 5 Data 6 20 GND 21 GND Ground Ground 9 D7 10 ACK- Data 7 Acknowledge / Interrupt [1] 22 GND 23 GND Ground Ground 11 BSY Busy / Wait [1] 24 GND Ground 12 PE 13 SLCT Paper End / User defined [1] Select / User defined [1] 25 GND -- -- Ground -- NOTES: [1] Standard and ECP mode function / EPP mode function [2] EPP mode function: Data Strobe ECP modes: Auto Feed or Host Acknowledge [3] EPP mode: user defined ECP modes:Fault or Peripheral Req. [4] EPP mode: Reset ECP modes: Initialize or Reverse Req. 5-8 www.hp.com Technical Reference Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

5-8
www.hp.com
Technical Reference Guide
Input/Output Interfaces
5.6.4 Parallel Interface Connector
Figure 5-5 and Table 5-5 show the connector and pinout of the parallel interface connector. Note
that some signals are redefined depending on the port's operational mode.
Figure 5-5.
DB-25 Parallel Interface Connector (as viewed from rear of chassis)
NOTES:
[1] Standard and ECP mode function / EPP mode function
[2]
EPP mode function: Data Strobe
ECP modes: Auto Feed or Host Acknowledge
[3]
EPP mode: user defined
ECP modes:Fault or Peripheral Req.
[4]
EPP mode: Reset
ECP modes: Initialize or Reverse Req.
Table 5-5.
DB-25 Parallel Connector Pinout
Pin
Signal
Function
Pin
Signal
Function
1
STB-
Strobe / Write [1]
14
LF-
Line Feed
[2]
2
D0
Data 0
15
ERR-
Error [3]
3
D1
Data 1
16
INIT-
Initialize Paper [4]
4
D2
Data 2
17
SLCTIN-
Select In / Address. Strobe [1]
5
D3
Data 3
18
GND
Ground
6
D4
Data 4
19
GND
Ground
7
D5
Data 5
20
GND
Ground
8
D6
Data 6
21
GND
Ground
9
D7
Data 7
22
GND
Ground
10
ACK-
Acknowledge / Interrupt [1]
23
GND
Ground
11
BSY
Busy / Wait [1]
24
GND
Ground
12
PE
Paper End / User defined [1]
25
GND
Ground
13
SLCT
Select / User defined [1]
--
--
--