HP xw3400 HP xw3400 Workstation - Hardware Reference Guide - Page 39
Specifications
View all HP xw3400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
A Specifications Desktop Dimensions Height 19.94 in 50.65 cm Width 6.98 in 17.73 cm Depth 16.88 in 42.87 cm Approximate Weight 23.5 lb 10.66 kg Temperature Range Operating 50° to 95°F 10° to 35°C Nonoperating -22° to 140°F -30° to 60°C Relative Humidity (noncondensing) Operating 10-90% 10-90% Nonoperating (38.7°C max wet bulb) 5-95% 5-95% Maximum Altitude (unpressurized) Operating 10,000 ft 3048 m Nonoperating 30,000 ft 9144 m NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed. Heat Dissipation Maximum 1575 BTU/hr 397 kg-cal/hr Typical (idle) 315 BTU/hr 80 kg-cal/hr Power Supply 115V 230V Operating Voltage Range1 90-132 VAC 180-264 VAC Rated Voltage Range 100-127 VAC 200-240 VAC Rated Line Frequency 50-60 Hz 50-60 Hz Power Output 300 W 300 W Rated Input Current (maximum)1 8A @ 100 VAC 4A @ 200 VAC 1 This system utilizes a passive power factor corrected power supply. The power factor correction is present in the 230V operating mode only. This allows the system to pass the CE mark requirements for use in the countries of the European Union. This supply requires the use of an input voltage range select switch. ENWW 33