Hitachi C12LSH Instruction Manual - Page 24
English, CAUTION
UPC - 717709010338
View all Hitachi C12LSH manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
English & CAUTION: When operating the digital panel, have the motor head section at the top limit position and the blade stopped. NOTE: • Before starting to cut, align the main unit to the miter angle 0° and the bevel angle 0° and hold down thier reset buttons for at least 0.2 second. If you press the digital display switch to ON without aligning the main unit to 0°, then the figures appearing on the digital display and the main unit angle will not match. • The laser marker will not light up if the digital display switch is turned off. (only on C12LSH) • Do not use the main unit near equipment that generates electrical noise such as generators. Electrical noise might cause faulty readings or operation on the digital display. • Side handle e Turntable Move the turntable left and right with the side handle loosened and set it to the correct position. Fig. 22-b a, CAUTION: If the figure shown on the miter angle digital display is different from the positive stop angle (for example, 45.0° -> 45.5°, 31.6° -, 32.0°) then the positive stop has probably deviated slightly from its correct position. If this happens, do as follows. (1) Move the turntable left and right with the side handle loosened, and set the turntable to the correct position. (2) If the figures on the display and positive stop still do not match, then return the turntable to the 0° position. Next move the turntable left and right with the side handle loosened as shown in Fig. 22-b. After setting it to the correct position 0°, press the reset button again as shown in Fig. 21. 24