IBM 8488 Hardware Maintenance Manual - Page 117
XXX-0NN
UPC - 000435695277
View all IBM 8488 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
Error code/symptom FRU/action 166-342-000 System Management: Failed (RSA BIST indicate failed tests.) 1. Make sure that the latest firmware levels for Remote Supervisor Adapter II and BIOS are installed. 2. Disconnect all server and option power cords from the server, wait 30 seconds, reconnect, and retry. 3. Remote Supervisor Adapter II. 180-XXX-000 (Diagnostics LED failure) v Run diagnostic LED test for the failing LED. 180-XXX-001 (Failed Front LED panel test) v Information LED panel 180-XXX-002 (Failed Diagnostics LED panel test) v System board 180-XXX-003 (Failed system board LED test) v System board 180-XXX-005 (Failed SCSI Backplane LED test) 1. SCSI backplane 2. SCSI backplane cable 3. System board 201-XXX-0NN (Failed Memory test, see "Installing a memory module" on page 34) 1. DIMM Location slots 1-6 where NN = DIMM location. Note: NN 1=DIMM 1 NN 2=DIMM 2 NN 3=DIMM 3 NN 4=DIMM 4 NN 5=DIMM 5 NN 6=DIMM 6 2. System board 202-XXX-001 (Failed System Cache test) 1. Microprocessor 1 2. System board 202-XXX-002 (Failed System Cache test) 1. Microprocessor 2 2. System board 206-XXX-000 (Failed Diskette Drive test) 1. Rerun the test with another diskette. 2. Diskette drive cables. 3. Diskette drive. 4. System board. 214-XXX-000 (Failed Diskette Drive test) 1. Rerun the test with another diskette. 2. Cable. 3. Diskette drive. 4. System board. 215-XXX-000 (Failed IDE CD-ROM test) 1. Rerun the test with a different CD. 2. CD-ROM drive cables. 3. CD-ROM drive. 4. System board. 217-198-XXX (Could not establish drive parameters) 1. Check the cable and termination. 2. SCSI backplane. 3. Hard disk drive. . 217-XXX-000 (Failed Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 1. Fixed Disk 1 2. System board 217-XXX-001 (Failed BIOS Fixed Disk test) 1. Fixed Disk 2 Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 2. System board Chapter 6. Symptom-to-FRU index 107