IBM 8646 Hardware Maintenance Manual - Page 103

Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S., Adapter in Slot N

Page 103 highlights

Error Code/Symptom FRU/Action 015-XXX-001 (USB interface 1. System Board not found, board damaged) 015-XXX-015 (Failed USB External Loopback test) 1. Make sure parallel port is not disabled 2. Re-run USB External Loopback test 3. System Board 015-XXX-198 (USB device connected during USB test) 1. Remove USB devices from USB1 and USB2 2. Re-run test 3. System Board 020-XXX-000 (Failed PCI Interface test) 1. System Board 030-XXX-000 (Failed Internal 1. System Board SCSI interface test) 030-XXX-00N (Failed SCSI test on PCI slot N. Check system error log before replacing a FRU.) 1. Adapter in Slot N 035-XXX-099 1. No adapters were found. 2. If adapter is installed re-check connection. 035-XXX-S99 (Failed RAID test on PCI slot S. S = number of failing PCI slot. Check System Error Log before replacing a FRU.) 1. Adapter 2. SCSI Backplane 3. Cable 035-XXX-SNN (Check System 1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S. Error Log before replacing a FRU. S = number of failing PCI slot; NN = SCSI ID of failing fixed disk.) 035-253-S99 (RAID adapter initialization failure) 1. ServeRAID Adapter in slot S is not configured properly. Obtain the basic and extended configuration status and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable 3. Adapter 075-XXX-000 (Failed Power 1. Power Supply Supply test) 089-XXX-001 (Failed Microprocessor test) 1. Microprocessor 089-XXX-002 (Failed Optional 1. Optional Microprocessor 2 Microprocessor test) 166-198-000 System Management: Aborted 1. Rerun the Diagnostic test 2. Disconnect all server and option power cords from server, wait 30 seconds, (Unable to communicate with reconnect, and retry. ASM adapter. It may be busy. 3. Advanced System Management adapter Run the test again.) (Communication with the ASM adapter has failed.) Symptom-to-FRU index 95

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156

Error Code/Symptom
FRU/Action
015-XXX-001
(USB interface
not found, board damaged)
1.
System Board
015-XXX-015
(Failed USB
External Loopback test)
1.
Make sure parallel port is not disabled
2.
Re-run USB External Loopback test
3.
System Board
015-XXX-198
(USB device
connected during USB test)
1.
Remove USB devices from USB1 and USB2
2.
Re-run test
3.
System Board
020-XXX-000
(Failed PCI
Interface test)
1.
System Board
030-XXX-000
(Failed Internal
SCSI interface test)
1.
System Board
030-XXX-00N
(Failed SCSI
test on PCI slot N. Check
system error log before
replacing a FRU.)
1.
Adapter in Slot N
035-XXX-099
1.
No adapters were found.
2.
If adapter is installed re-check connection.
035-XXX-S99
(Failed RAID
test on PCI slot S. S =
number of failing PCI slot.
Check System Error Log
before replacing a FRU.)
1.
Adapter
2.
SCSI Backplane
3.
Cable
035-XXX-SNN
(Check System
Error Log before replacing a
FRU. S = number of failing
PCI slot; NN = SCSI ID of
failing fixed disk.)
1.
Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
035-253-S99
(RAID adapter
initialization failure)
1.
ServeRAID Adapter in slot S is not configured properly.
Obtain the basic and
extended configuration status and refer to the ServeRAID Hardware Maintenance
Manual for more information.
2.
Cable
3.
Adapter
075-XXX-000
(Failed Power
Supply test)
1.
Power Supply
089-XXX-001
(Failed
Microprocessor test)
1.
Microprocessor
089-XXX-002
(Failed Optional
Microprocessor test)
1.
Optional Microprocessor 2
166-198-000 System
Management: Aborted
(Unable to communicate with
ASM adapter. It may be busy.
Run the test again.)
(Communication with the
ASM adapter has failed.)
1.
Rerun the Diagnostic test
2.
Disconnect all server and option power cords from server, wait 30 seconds,
reconnect, and retry.
3.
Advanced System Management adapter
Symptom-to-FRU index
95