IBM 8659-71Y Maintenance Manual - Page 156
Bypassing an Unknown Power-on, Password
![]() |
UPC - 087944526346
View all IBM 8659-71Y manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 156 highlights
Table 12. Switch Settings for Microprocessor Speed 350 MHz 12345678 ON OFF 400 MHz 12345678 ON OFF 450 MHz 12345678 ON OFF Bypassing an Unknown Power-on Password: When a power-on password is set, POST does not complete until you enter the password. If you forget the power-on password, you can regain access to the server through one of the following methods: Enter the administrator password at the power-on prompt, if an administrator password has been set. (If necessary, see "Using the Administrator Password Menu" on page 27 for details.) Start the Configuration/Setup Utility programs and change the power-on password. See "Using the Power-on Password Menu" on page 26. Change switch 8 on the system switch block to On (Bypass Power-On Password). See "System Board Connectors" on page 143 for the location of the switch block. 148 Netfinity Server HMM