IBM 8659-71Y Maintenance Manual - Page 44
NDIS 2.01 OS/2 Driver Messages
![]() |
UPC - 087944526346
View all IBM 8659-71Y manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
PCNTNW-NW-165 The device was not found at IOADDRESS. Explanation: The Ethernet controller cannot be found at the I/O address specified. Action: The Ethernet controller does not require a parameter for the I/O address. Remove the I/O address parameter. PCNTNW-NW-167 PCI scan specified, device not found. Explanation: The driver cannot locate the Ethernet controller on the PCI bus. Action: Verify that the PCI Ethernet device type is set to the default (enabled) position in the Configuration/Setup utility programs (see "PCI Bus Control" on page 30). If the problem persists, go to "Diagnostic Test Programs" on page 11 to run the diagnostic utility. PCNTNW-NW-180 The DMA parameter is not necessary for PCI device. Explanation: The Ethernet controller does not require a DMA setting. Action: None necessary, message is for information only. NDIS 2.01 (OS/2) Driver Messages: The following error messages are for the NDIS 2.01 (OS/2) drivers. The explanation and recommended action are included with each message. PCNTND-1 Unable to open the Protocol Manager. Explanation: The NDIS stack is not configured correctly. Action: Check and correct your configuration. PCNTND-6 Out of memory while allocating buffers. Explanation: The driver could not allocate the requested buffers. Action: Check your system configuration. Edit the PROTOCOL.INI file to reduce the number of Txbuffers and Rxbuffers specified for the driver. PCNTND-7 A Protocol Manager device error occurred. Explanation: The NDIS stack is not configured correctly. Action: Check and correct your configuration. PCNTND-8 Bad status for the Protocol Manager. Explanation: The NDIS stack is not configured correctly in the PROTOCOL.INI file. Action: Check and correct your configuration. PCNTND-9 Cannot find the PROTOCOL.INI entry. Explanation: The NDIS stack is not configured correctly in the PROTOCOL.INI file. Action: Check and correct your configuration. PCNTND-10 The Protocol Manager Input Output Control (IOCTL) failed. Explanation: The NDIS stack is not configured correctly in the PROTOCOL.INI file. Action: Check and correct your configuration. PCNTND-11 Protocol Manager registration failed. Explanation: The NDIS stack is not configured correctly. Action: Check and correct your configuration. 36 Netfinity Server HMM
![](/manual_guide/products/ibm-865971y-maintenance-manual-737f5fc/44.png)