IBM 8659-71Y Maintenance Manual - Page 171
Error Code/Symptom, FRU/Action, System Board, Fixed Disk Cables, Configuration/Setup, Remove Failing
UPC - 087944526346
View all IBM 8659-71Y manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 171 highlights
Error Code/Symptom 1600, 1601 (The system is able to communicate to the Service Processor, but the Service Processor failed to respond at the start of POST.) Do the following before replacing a FRU: 1. Remove the AC power to the system, wait 20 seconds; then, re-connect the AC power. Wait 30 seconds; then, power-on the system. 2. Flash update the Service Processor. 1762 (Fixed Disk Configuration error) 178X (Fixed Disk error) 1800 (No more hardware interrupt available for PCI adapter) 1801 (No room for PCI option ROM) 1802 (No more I/O space available for PCI adapter) 1803 (No more memory (above 1MB for PCI adapter) 1804 (No more memory (below 1MB for PCI adapter) 1805 (PCI option ROM checksum error) FRU/Action 1. System Board 1. Fixed Disk Cables 2. Run Configuration/Setup 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. System Board 1. Fixed Disk Cables 2. Run Diagnostics 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Move the failing adapter to slot 1 or 2 3. Failing Adapter 4. System Board 1. Remove Failing PCI Card 2. System Board Netfinity 5000 - Type 8659 163