IBM 8659-71Y Maintenance Manual - Page 171

Error Code/Symptom, FRU/Action, System Board, Fixed Disk Cables, Configuration/Setup, Remove Failing

Page 171 highlights

Error Code/Symptom 1600, 1601 (The system is able to communicate to the Service Processor, but the Service Processor failed to respond at the start of POST.) Do the following before replacing a FRU: 1. Remove the AC power to the system, wait 20 seconds; then, re-connect the AC power. Wait 30 seconds; then, power-on the system. 2. Flash update the Service Processor. 1762 (Fixed Disk Configuration error) 178X (Fixed Disk error) 1800 (No more hardware interrupt available for PCI adapter) 1801 (No room for PCI option ROM) 1802 (No more I/O space available for PCI adapter) 1803 (No more memory (above 1MB for PCI adapter) 1804 (No more memory (below 1MB for PCI adapter) 1805 (PCI option ROM checksum error) FRU/Action 1. System Board 1. Fixed Disk Cables 2. Run Configuration/Setup 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. System Board 1. Fixed Disk Cables 2. Run Diagnostics 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Move the failing adapter to slot 1 or 2 3. Failing Adapter 4. System Board 1. Remove Failing PCI Card 2. System Board Netfinity 5000 - Type 8659 163

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218

Error Code/Symptom
FRU/Action
1600, 1601
(The system is able to
communicate to the Service
Processor, but the Service
Processor failed to respond
at the start of POST.)
Do the following before
replacing a FRU:
1.
Remove the AC power
to the system, wait 20
seconds; then,
re-connect the AC
power. Wait 30
seconds; then,
power-on the system.
2.
Flash update the
Service Processor.
1.
System Board
1762
(Fixed Disk Configuration
error)
1.
Fixed Disk Cables
2.
Run
Configuration/Setup
3.
Fixed Disk Adapter
4.
Fixed Disk Drive
5.
System Board
178X
(Fixed Disk error)
1.
Fixed Disk Cables
2.
Run Diagnostics
3.
Fixed Disk Adapter
4.
Fixed Disk Drive
5.
System Board
1800
(No more hardware interrupt
available for PCI adapter)
1.
Run
Configuration/Setup
2.
Failing Adapter
3.
System Board
1801
(No room for PCI option
ROM)
1.
Run
Configuration/Setup
2.
Failing Adapter
3.
System Board
1802
(No more I/O space
available for PCI adapter)
1.
Run
Configuration/Setup
2.
Failing Adapter
3.
System Board
1803
(No more memory (above
1MB for PCI adapter)
1.
Run
Configuration/Setup
2.
Failing Adapter
3.
System Board
1804
(No more memory (below
1MB for PCI adapter)
1.
Run
Configuration/Setup
2.
Move the failing
adapter to slot 1 or 2
3.
Failing Adapter
4.
System Board
1805
(PCI option ROM checksum
error)
1.
Remove Failing PCI
Card
2.
System Board
Netfinity 5000 - Type 8659
163