IBM 866441Y Hardware Maintenance Manual - Page 63
Specifications, Size Tower Model, Size Rack Model, Environment, Electrical Input
UPC - 087944522201
View all IBM 866441Y manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
Specifications The following table contains the specifications for the Netfinity 5600 server. Size (Tower Model) - Depth: 659.3 mm (26 in.) - Height: 426.5 mm (16.8 in.) - Width: 217.3 mm (8.6 in.) Size (Rack Model) - Depth: 629.3 mm (24.8 in.) - Height: 217.3 mm (8.6 in.) (5 U) - Width: 426.6 mm (16.8 in.) Weight (Tower Model) Minimum configuration: 26.6 kg (58.6 lb) Maximum configuration: 37.5 kg (82.7 lb) Weight (Rack Model) Minimum configuration: 25.3 kg (55.7 lb) Maximum configuration: 36.2 kg (79.8 lb) Environment Air temperature: - Server on: 10° to 35° C (50° to 95° F) Altitude: 0 to 914 m (3000 ft.) - Server on: 10° to 32° C (50° to 90° F) Altitude: 914 m (3000 ft.) to 2133 m (7000 ft.) - Server off: 10° to 43° C (50° to 110° F) Maximum Altitude: 2133 m (7000 ft.) Humidity: - Server on: 8% to 80% - Server off: 8% to 80% Maximum altitude: 2133 m (7000 ft) Electrical Input Sine-wave input (50 to 60 Hz) is required Input voltage: - Low range: - Minimum: 90 V ac - Maximum: 137 V ac - High range: - Minimum: 180 V ac - Maximum: 265 V ac - Input kilovolt-amperes (kVA) approximately: - Minimum configuration as shipped: 0.08 kVA - Maximum configuration: 0.52 kVA Power Available for Drives Each hot-swap drive bay: - +5 V dc line: 15 A Netfinity 5600 - Type 8664 55