Intel SE7221BA1 Product Specification - Page 71

Caution

Page 71 highlights

Intel® Entry Server Board SE7221BA1-E TPS Miscellaneous Board Information OM16996 Figure 19. Processor Heatsink for Omni-directional Airflow CAUTION Failure to ensure appropriate airflow may result in reduced performance of both the processor and/or voltage regulator or, in some instances, damage to the server board. For a list of chassis that have been tested with Intel server boards please refer to the following website: http://support.intel.com/support/processors/pentium4/ All responsibility for determining the adequacy of any thermal or system design remains solely with the integrator. Intel makes no warranties or representations that merely following the instructions presented in this document will result in a system with adequate thermal performance. CAUTION Ensure that the ambient temperature does not exceed the Server Board's maximum operating temperature. Failure to do so could cause components to exceed their maximum case temperature and malfunction. CAUTION Ensure that proper airflow is maintained in the processor voltage regulator circuit. Failure to do so may result in damage to the voltage regulator circuit. The processor voltage regulator area (Figure 20, item A) can reach a temperature of up to 85 oC in an open chassis. Revision 1.5 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77

Intel® Entry Server Board SE7221BA1-E TPS
Miscellaneous Board Information
Revision 1.5
61
OM16996
Figure 19.
Processor Heatsink for Omni-directional Airflow
CAUTION
Failure to ensure appropriate airflow may result in reduced performance of both the
processor and/or voltage regulator or, in some instances, damage to the server board.
For a list of chassis that have been tested with Intel server boards please refer to the
following website:
All responsibility for determining the adequacy of any thermal or system design remains
solely with the integrator.
Intel makes no warranties or representations that merely
following the instructions presented in this document will result in a system with adequate
thermal performance.
CAUTION
Ensure that the ambient temperature does not exceed the Server Board’s maximum
operating temperature.
Failure to do so could cause components to exceed their
maximum case temperature and malfunction.
CAUTION
Ensure that proper airflow is maintained in the processor voltage regulator circuit.
Failure
to do so may result in damage to the voltage regulator circuit.
The processor voltage
regulator area (Figure 20, item A) can reach a temperature of up to 85
o
C in an open
chassis.