Intel SR1560SF Service Guide - Page 54
Installing and Removing a Hot-swap Hard Drive - server system sr1560sfhs
UPC - 735858196017
View all Intel SR1560SF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
Installing and Removing a Hot-swap Hard Drive Up to three hot-swap SAS or SATA drives can be installed in the Intel® Server System SR1560SF - product code SR1560SFHS. Cautions: If you install less than three drives or devices, the empty drive bays must be occupied by carriers with drive blanks to maintain proper system cooling. To avoid possible damage to your server system, use only the drive carriers that came with your system. Note: See "Server System References" for an Internet link to a list of supported hardware. Installing a SAS or SATA Hot-swap Hard Disk Drive 1. Open the latch at the front of the hard drive carrier (see letter "A"). 2. Pull out on the black lever and slide the carrier from the server system (see letter "B"). B A TP02206 Figure 29. Removing Hot-swap Disk Carrier from the Server System 3. Remove the four screws that attach the plastic retention device or the previously installed hard drive to the drive carrier (see letter "A"). Two screws are at each side of the retention device or the hard drive. Remove the drive blank (see letter "B") and store it for future use. B A TP02207 Figure 30. Removing Drive Blank from Drive Carrier 32 Intel® Server System SR1560SF Service Guide