Intel SR1560SF Service Guide - Page 69
Replacing the Server Board
UPC - 735858196017
View all Intel SR1560SF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
Installing the Fan Board 1. Lower the fan board into the system (see letter "A") and position the fan board over the retention pins as shown. 2. Slide the fan board to the left (see letter "B") to lock it in place and install the screw (see letter "C"). 3. Connect power to the fan board power connector (see letter "D"). D C B A AF002350 Figure 53. Installing the Fan Board into the Server System 4. Connect fan cables to the fan board. Replacing the Server Board Removing the Server Board 1. Remove CPU air duct and blue air baffle. 2. If installed, remove memory, processor heat sinks, and processors from the server board. 3. If installed, remove bridge board (hot-swap systems only). 4. If installed, remove the PCI riser assembly. 5. If installed, disconnect all SATA cables from the server board. Intel® Server System SR1560SF Service Guide 47