Intel SR1560SF Service Guide - Page 74
Replacing the Control Panel Module Hot-swap, Drive System
![]() |
UPC - 735858196017
View all Intel SR1560SF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 74 highlights
The power supply can be replaced if it fails or if one of the fans that is integrated into it fails. To replace the power supply, use the following instructions. 1. Disconnect all power cables. 2. Lift the power supply to disengage it from the latch (see letter "A") and remove the power supply by sliding it out (see letter "B"). B A supply, re-connect all power cables in step 1 above, and reconnect AC power cord. AF002358 Figure 57. Removing Power Supply from the Server System 3. Insert the replacement power supply module (see letter "A") until it clicks into place behind the latch (see letter "B"). Reconnect all power cables. A B supply, re-connect all power cables in step 1 above, and reconnect AC power cord. AF002359 Figure 58. Installing Power Supply into the Server System Replacing the Control Panel Module (Hot-swap Drive System) Your server must be operated with a control panel installed. Caution: The control panel is NOT hot-swappable. Before removing or replacing the control panel, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet. 52 Intel® Server System SR1560SF Service Guide