Intel SR1560SF Service Guide - Page 61

Installing the PCI Riser Assembly

Page 61 highlights

AF002354 Figure 40. Removing PCI Riser Assembly from the Server System Installing the PCI Riser Assembly 1. Lower the riser assembly into place (see letter "A"). 2. Align the two hooks in the riser assembly with the matching slots at the back of the server system (see letter "B"). A B AF002355 Figure 41. Installing PCI Riser Assembly into the Server System 3. Press down uniformly until the two hooks on the rear of the PCI riser assembly engage the server system back panel slots. The riser card will seat into the matching socket on the server board. Ensure that the riser card is fully seated. Intel® Server System SR1560SF Service Guide 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158

Intel
®
Server System SR1560SF Service Guide
39
Figure 40. Removing PCI Riser Assembly from the Server System
Installing the PCI Riser Assembly
1.
Lower the riser assembly into place (see letter “A”).
2.
Align the two hooks in the riser assembly with the matching slots at the back of the
server system (see letter “B”).
Figure 41. Installing PCI Riser Assembly into the Server System
3.
Press down uniformly until the two hooks on the rear of the PCI riser assembly
engage the server system back panel slots. The riser card will seat into the matching
socket on the server board. Ensure that the riser card is fully seated.
AF002354
AF002355
A
B