Intel SR1560SF Service Guide - Page 65

Installing/Replacing the Backplane Board Hot, swap Drive System Only

Page 65 highlights

Removing the Intel® RMM2 and Intel® RMM2 NIC 1. Remove the Intel® RMM2 board (see letter "A") and standoffs (see letter "B") from the server board . 2. Remove the Intel® RMM2 NIC module (see letter "C") and standoffs (see letter "D") from the server board. 3. Install the Intel® RMM2 NIC module cover into the system back panel. A B C D AF002379 Figure 47. Removing the Intel® RMM and the Intel® RMM NIC Module from the Server System Installing/Replacing the Backplane Board (Hotswap Drive System Only) The instructions below describe how to install and replace the backplane board. Installing the Backplane Board 1. Lower the backplane board into the system (see letter "A") and position the backplane board over the retention pins as shown. 2. Slide the backplane board to the left (see letter "B") to lock it in place and tighten the captive screw (see letter "C"). 3. Connect power to the backplane power connector (see letter "D"). Intel® Server System SR1560SF Service Guide 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158

Intel
®
Server System SR1560SF Service Guide
43
Removing the Intel
®
RMM2 and Intel
®
RMM2 NIC
1.
Remove the Intel
®
RMM2 board (see letter “A”) and standoffs (see letter “B”)
from the server board .
2.
Remove the Intel
®
RMM2 NIC module (see letter “C”) and standoffs (see letter
“D”) from the server board.
3.
Install the Intel
®
RMM2 NIC module cover into the system back panel.
Figure 47. Removing the Intel
®
RMM and the Intel
®
RMM NIC Module from
the Server System
Installing/Replacing the Backplane Board (Hot-
swap Drive System Only)
The instructions below describe how to install and replace the backplane board.
Installing the Backplane Board
1.
Lower the backplane board into the system (see letter “A”) and position the
backplane board over the retention pins as shown.
2.
Slide the backplane board to the left (see letter “B”) to lock it in place and tighten
the captive screw (see letter “C”).
3.
Connect power to the backplane power connector (see letter “D”).
AF002379
D
C
B
A