Intel SR1690WB Service Guide - Page 59
Removing a Slimline Optical Drive, Installing and Removing the PCI Riser Assembly
UPC - 735858210980
View all Intel SR1690WB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
Removing a Slimline Optical Drive 1. Disconnect the SATA power from system power supply and SATA cable connector from server board. 2. Press the optical latch and slide the optical drive assembly out of the chassis. 3. Install slimline drive bay filler blank, if no optical drive installed. Installing and Removing the PCI Riser Assembly Removing the PCI Riser Assembly 1. Disconnect any cables attached to any add-in cards. 2. Grasp the riser assembly and pull up to release it from the system. AF003322 Figure 31. Removing the PCI Riser Assembly from the Server System Installing the PCI Riser Assembly 1. Lower the riser assembly into place (see letter "A"). 2. Align the two hooks in the riser assembly with the matching slots at the back of the server system (see letter "B"). Intel® Server System SR1690WB Service Guide 41